Parametric study of a bubble removing device for hemodialysis
Tóm tắt
Từ khóa
Tài liệu tham khảo
Jonsson PA-O, Lindmark L, Axelsson J, Karlsson L, Lundberg L, Stegmayr B. Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers. Artificial Organs. 2018;42(5):533–9.
Roosenhoff TPA, Stehouwer MC, De Vroege R, Butter RP, Van Boven W-J, Bruins P. Air Removal Efficiency of a Venous Bubble Trap in a Minimal Extracorporeal Circuit During Coronary Artery Bypass Grafting. Artif Organs. 2010;34(12):1092–8.
Schönburg M, Urbanek P, Erhardt G, Taborski U, Plechinger H, Hein S, et al. A dynamic bubble trap reduces microbubbles during cardiopulmonary bypass: a case study. J Extra Corpor Technol. 2000;32(3):165–9.
Wagner S, Rode C, Wojke R, Canaud B. Observation of microbubbles during standard dialysis treatments. Clin Kidney J. 2015;8(4):400–4.
Barak M, Nakhoul F, Katz Y. Reviews: Pathophysiology and Clinical Implications of Microbubbles during Hemodialysis. Semin Dial. 2008;21(3):232–8.
Stegmayr B, Brännström T, Forsberg U, Jonson P, Stegmayr C, Hultdin J. Microbubbles of Air May Occur in the Organs of Hemodialysis Patients. ASAIO J. 2012;58(2):177-9.
Forsberg U, Jonsson P, Stegmayr B. Air contamination during medical treatment results in deposits of microemboli in the lungs: An autopsy study. Int J Artif Organs. 2019;42(9):477–81.
Stegmayr B. Air contamination during hemodialysis should be minimized. Hemodial Int. 2017;21(2):168–72.
Matsuda K, Fissell R, Ash S, Stegmayr B. Long-Term Survival for Hemodialysis Patients Differ in Japan Versus Europe and the USA. What Might the Reasons Be? Artificial Organs. 2018;42(12):1112–8.
Woltmann D, Fatica RA, Rubin JM, Weitzel W. Ultrasound detection of microembolic signals in hemodialysis accesses. Am J Kidney Dis. 2000;35(3):526–8.
Hai N, Nam H, Vu Quoc T, Thi T, Ha T, Minh N, et al., editors. Air bubbles detection and alarm in the blood stream of dialysis using capacitive sensors. International Conference on Engineering Mechanics and Automation (ICEMA3); 2014 15–16 October 2014; Hanoi.
Amir M, Usmani AY, Varshney M, Anwer SF, Khan SA, Islam N, et al. Analysing Spatio-temporal flow hemodynamics in an artery manifesting stenosis. Int J Mech Sci. 2022;218: 107072.
Keshavarzi G, Barber TJ, Yeoh G, Simmons A, Reizes JA. Two-Dimensional Computational Analysis of Microbubbles in Hemodialysis. Artif Organs. 2013;37(8):E139–44.
Keshavarzi G, Simmons A, Yeoh G, Barber T. Effectiveness of microbubble removal in an airtrap with a free surface interface. J Biomech. 2015;48:1237-40.
Zheng C, Yang W, Wang G, Fan G, Yan C, Zeng X, et al. Experimental Study on a New Type of Separator for Gas Liquid Separation. Front Energy Res. 2019;7. Online publication https://doi.org/10.3389/fenrg.2019.00102.
Cai B, Wang J, Sun L, Zhang N, Yan C. Experimental study and numerical optimization on a vane-type separator for bubble separation in TMSR. Prog Nucl Energy. 2014;74:1–13.
Van Nierop EA, Luther S, Bluemink JJ, Magnaudet J, Prosperetti A, Lohse D. Drag and lift forces on bubbles in a rotating flow. J Fluid Mech. 2007;571:439–54.
Dbouk T, Drikakis D. On coughing and airborne droplet transmission to humans. Phys Fluids (1994). 2020;32(5):053310.
Long S, Lau TCW, Chinnici A, Tian ZF, Dally BB, Nathan GJ. Characteristics of swirling and precessing flows generated by multiple confined jets. Physics of Fluids. 2019;31(5). Online publication https://doi.org/10.1063/1.5089904.
Vaidya HA, Ertunç Ö, Genç B, Beyer F, Köksoy Ç, Delgado A. Numerical simulations of swirling pipe flows- decay of swirl and occurrence of vortex structures. J Physics Conference Series. 2011;318(6). Online publication https://doi.org/10.1088/1742-6596/318/6/062022.
Hrncír E, Rosina J. Surface tension of blood. Physiol Res. 1997;46(4):319–21 ((0862-8408)).