Overdenture attachment selection and the loading of implant and denture‐bearing area. Part 2: A methodical study using five types of attachment

Clinical Oral Implants Research - Tập 12 Số 6 - Trang 640-647 - 2001
Siegfried M. Heckmann1, Manfred Wichmann1, Werner Winter2, Martin Meyer3, Hans‐Peter Weber4
1School of Dental Medicine, University of Erlangen-Nuremberg, Germany
2Institute of Applied Mechanics, University of Erlangen‐Nuremberg, Germany.
3Epidemiological Cancer Registry Bavaria, University of Erlangen‐Nuremberg, Germany.
4Department of Restorative Dentistry, Harvard School of Dental Medicine, Boston, Massachusetts, USA.

Tóm tắt

Abstract: In general, an implant is loaded via axial and horizontal forces. Besides this, moment loading can also occur. The aim of this study was to investigate how different prosthetic connectors with overdentures develop force transfer to implant and bone as well as to the denture‐bearing alveolar ridge. Five connectors were investigated on a stereolithographic model fabricated according to a real patient situation. The model was fitted with strain gauges on the “bone” distal and medial to the implants and with vertical force transducers in the alveolar “bone” under the denture‐bearing area. The parallel‐sided rigid telescopic connector developed the highest moment loading of the implant (P<0.001), which would suggest restraint in the use of this connector. The bar construction also showed somewhat high moments but these may have been at least partly exaggerated by the individual patient situation. Loading results through the non‐rigid telescopic copings, single spherical attachments and magnet overdentures demonstrated a low level of implant moment loading which would in part result from horizontal forces caused by denture forward shift during force application. The denture‐bearing area loading was different with all attachments (P<0.001) and was related to the rigidity of the connector and reached the highest values with the non‐rigid telescopic coping. The clinical implications of the various findings are discussed.

Từ khóa


Tài liệu tham khảo

Davis D.M., 1999, Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets: 5‐year results, International Journal of Prosthodontics, 12, 222

10.14219/jada.archive.1999.0372

Geering A.H., 1993, Color Atlas of Dental Medicine

Gotfredsen K., 2000, Implant‐supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5‐year study, International Journal of Prosthodontics, 13, 125

Heckmann S., 1993, Erste Erfahrungen mit Resilienzteleskopen bei der prothetischen Versorgung enossaler Implantate, Zeitschrift für Zahnärztliche Implantologie, 9, 188

Heckmann S., 1996, Zur Verlaufsmessung der Implantatfestigkeit bei teleskop‐stabilisiertem totalem Zahnersatz, Zeitschrift für Zahnärztliche Implantologie, 12, 148

Heckmann S.M., 2001, Implants and resilient telescopic crowns to improve chewing and predigesting capacity in severely handicapped Parkinson’s disease patients. A pilot study, Clinical Oral Implants Research

Jäger K., 1993, In vitro Spannungsanalysen an Implantaten in Abhängigkeit von den hybridprothetischen Suprakonstruktionen, Zeitschrift für Zahnärztliche Implantologie, 9, 42

10.1016/S0022-3913(98)70032-0

10.1034/j.1600-0501.1996.070405.x

10.1034/j.1600-0501.1997.080209.x

10.1111/j.1365-2842.1997.tb00258.x

10.1007/s007840050022

10.1034/j.1600-0501.1998.090304.x

10.1046/j.1365-2842.1999.00369.x

Riley M.A., 1999, Investigations into the failure of dental magnets, International Journal of Prosthodontics, 12, 249

10.1177/00220345980770020701

Spiekermann H., 1995, Color Atlas of Dental Medicine