Optimizing Impedance Change Measurement During Radiofrequency Ablation Enables More Accurate Characterization of Lesion Formation

JACC: Clinical Electrophysiology - Tập 7 - Trang 471-481 - 2021
Pierre C. Qian1,2,3, Duc Minh Nguyen4,5, Michael Anthony Barry1,3,4, Vu Tran1,3, Juntang Lu1,3, Aravinda Thiagalingam2,3, Stuart P. Thomas1,2,3, Alistair McEwan4
1Westmead Hospital, Sydney, Australia
2Faculty of Medicine, University of Sydney, Sydney, Australia
3Westmead Applied Research Centre, Sydney, Australia
4Faculty of Engineering and Information Technology, University of Sydney, Sydney, Australia
5Department of Biomedical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam

Tài liệu tham khảo

Ikeda, 2014, Circ Arrhythm Electrophysiol, 7, 1174, 10.1161/CIRCEP.113.001094 Sapp, 2004, Ablation lesion size correlates with pacing threshold: a physiological basis for use of pacing to assess ablation lesions, Pacing Clin Electrophysiol, 27, 933, 10.1111/j.1540-8159.2004.00561.x Bortone, 2013, Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium, Circ Arrhythm Electrophysiol, 6, 1095, 10.1161/CIRCEP.113.000749 Harvey, 1992, Impedance monitoring during radiofrequency catheter ablation in humans, Pacing Clin Electrophysiol, 15, 22, 10.1111/j.1540-8159.1992.tb02897.x Chikata, 2016, Optimal force-time integral for pulmonary vein isolation according to anatomical wall thickness under the ablation line, J Am Heart Assoc, 5 Das, 2016, Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values, Europace, 19, 775 Squara, 2014, Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions, Europace, 16, 660, 10.1093/europace/euu068 Whitaker, 2018, Lesion index–guided ablation facilitates continuous, transmural, and durable lesions in a porcine recovery model, Circulation Arrhythm Electrophysiol, 11, 10.1161/CIRCEP.117.005892 Vergara, 2011, Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla, Heart Rhythm, 8, 295, 10.1016/j.hrthm.2010.10.032 Esrick, 1994, The effect of hyperthermia-induced tissue conductivity changes on electrical impedance temperature mapping, Phys Med Biol, 39, 133, 10.1088/0031-9155/39/1/008 Nguyen, 2019, Self-weighted NOSER-prior electrical impedance tomography using internal electrodes in cardiac radiofrequency ablation, Physiol Meas, 40, 10.1088/1361-6579/ab1937 Nguyen, 2020, Cardiac radiofrequency ablation tracking using electrical impedance tomography, Biomed Phys Eng Exp, 6 Nguyen, 2020, The region-of-interest based measurement selection process for electrical impedance tomography in radiofrequency cardiac ablation with known anatomical information, Biomed Signal Process Control, 56, 101706, 10.1016/j.bspc.2019.101706 Shah, 2010, Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model, J Cardiovasc Electrophysiol, 21, 1038, 10.1111/j.1540-8167.2010.01750.x Bar-Tal, 2017 Mori, 2019, Relationship between the ablation index, lesion formation, and incidence of steam pops, J Arrhythm, 35, 636 McRae, 1993, Changes in electrical impedance of skeletal muscle measured during hyperthermia, Int J Hypertherm, 9, 247, 10.3109/02656739309022538 Haines, 1990, Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium, Circulation, 82, 1034, 10.1161/01.CIR.82.3.1034 Avitall, 1997, The effects of electrode-tissue contact on radiofrequency lesion generation, Pacing Clin Electrophysiol, 20, 2899, 10.1111/j.1540-8159.1997.tb05458.x Reichlin, 2014, Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters, Heart Rhythm, 11, 194, 10.1016/j.hrthm.2013.10.048 Seiler, 2008, Steam pops during irrigated radiofrequency ablation: feasibility of impedance monitoring for prevention, Heart Rhythm, 5, 1411, 10.1016/j.hrthm.2008.07.011 Strickberger, 1995, Relation between impedance and temperature during radiofrequency ablation of accessory pathways, Am Heart J, 130, 1026, 10.1016/0002-8703(95)90204-X Thiagalingam, 2007, Impedance and temperature monitoring improve the safety of closed-loop irrigated-tip radiofrequency ablation, J Cardiovasc Electrophysiol, 18, 318, 10.1111/j.1540-8167.2006.00745.x Vest, 2008, Clinical use of cooled radiofrequency ablation, J Cardiovasc Electrophysiol, 19, 769, 10.1111/j.1540-8167.2008.01193.x Wang, 1995, Factors influencing impedance during radiofrequency ablation in humans, Chin Med J, 108, 450 Nguyen, 2020, Cardiac radiofrequency ablation tracking using electrical impedance tomography, Biomed Phys Eng Express, 84, 36