Optimized distortion correction of epi-based statistical parametrical maps for stereotactic neurosurgery

Magnetic Resonance Imaging - Tập 22 - Trang 163-170 - 2004
Stefan Hunsche1, Dieter Sauner2, Harald Treuer1, Moritz Hoevels1, Volker Hesselmann3, Oliver Schulte3, Klaus Lackner3, Sturm Volker3
1Department for Stereotactic and Functional Neurosurgery, University of Cologne, Cologne, Germany
2Institute for Diagnostic and Interventional Radiology, Friedrich-Schiller-University of Jena, Jena, Germany
3Department of Radiology, University of Cologne, Cologne, Germany

Tài liệu tham khảo

Sturm, 1983, Stereotactic computer tomography with a modified Riechert–Mundinger device as the basis for integrated stereotactic neuroradiological investigations, Acta Neurochir Wien, 68, 7, 10.1007/BF01406197 Schad, 1987, Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors, JCAT, 11, 948 Hill, 1999, Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm, JCAT, 22, 317 Ogawa, 1990, Oxygenation–sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields, Magn Reson Med, 14, 68, 10.1002/mrm.1910140108 Mansfield, 1977, Multi–planar image formation using NMR spin echoes, J Phys C, 10, L55, 10.1088/0022-3719/10/3/004 Schmitt, 1998 Wan, 1997, Reduction of geometric and intensity distortions in echo–planar imaging using a mulireference scan, Magn Reson Med, 37, 932, 10.1002/mrm.1910370619 Chen, 2001, Optimized distortion correction technique for echo planar imaging, Magn Reson Med., 45, 525, 10.1002/1522-2594(200103)45:3<525::AID-MRM1070>3.0.CO;2-S Studholme, 2000, Accurate alignment of functional EPI data to anatomical MRI using a physics–based distortion model, IEEE Trans Med Imag, 19, 1115, 10.1109/42.896788 Kybic, 2000, Unwarping of unidirectionally distorted EPI images, IEEE Trans Med Imag, 19, 80, 10.1109/42.836368 Weisskopf RM, Davis TL. Correcting gross distortion in echo planar images. Proc SMRM, 11th Annual Meeting, Berlin, 1991. p. 4515 Jezzard, 1995, Correction for geometrical distortion in echo planar images from B0 field variations, Magn Reson Med, 34, 65, 10.1002/mrm.1910340111 Reber, 1998, Correction of off–resonance related distortion in echo–planar imaging using EPI–based field maps, Magn Reson Med, d39, 328, 10.1002/mrm.1910390223 Friston, 1995, Spatial registration and normalization of images, Human Brain Mapping, 2, 165, 10.1002/hbm.460030303 Friston, 1995, Statistical parametric maps in functional imaging, Hum Brain Mapp, 2, 189, 10.1002/hbm.460020402 Press WH, Teukolsky SA, Vetterling WT, Flannery BP. Numerical recipes in C: the art of scientific computing, 2nd ed. Cambridge: Cambridge University Press, 1992. p. 408–12 Zhou, 1998, Concomitant magnetic–field–induced artifacts in axial echo planar imaging, Magn Reson Med, 39, 596, 10.1002/mrm.1910390413 Norris, 1990, Concomitant magnetic field gradients and there effects on imaging at low magnetic field strengths, Magn Reson Imaging, 8, 33, 10.1016/0730-725X(90)90209-K Jezzard, 1998, Characterization of and correction for eddy current artifacts in echo planar diffusion imaging, Magn Reson Med., 39, 801, 10.1002/mrm.1910390518