Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy
Tài liệu tham khảo
Columbo, 1985, External stereotactic irradiation by a linear accelerator, Neurosurgery, 16, 154, 10.1227/00006123-198502000-00005
Hartmann, 1985, Cerebral irradiation therapy using moving field irradiation at a linear accelerator facility, Int. J. Radiat. Oncol. Biol. Phys., 11, 1185, 10.1016/0360-3016(85)90068-9
Winston, 1988, Linear accelerator as a neurosurgical tool for stereotactic radiosurgery, Neurosurgery, 22, 454, 10.1227/00006123-198803000-00002
Lutz, 1988, A system for stereotactic radiosurgery with a linear accelerator, Int. J. Radiat. Oncol. Biol. Phys., 14, 373, 10.1016/0360-3016(88)90446-4
Maitz, 1998, Treatment planning of stereotactic convergent gamma-ray irradiation using Co-60 sources, Med. Dosim., 23, 169, 10.1016/S0958-3947(98)00022-3
Kooy, H.M.; Bellerive, M.R.; Loeffler, J.S. Teletherapy: Present and future, Proceedings of the 1996 AAPM Summer School. In: Mackie, R.T.; Palta, J.R., editors. Stereotactic Radiotherapy. Madison: Advanced Medical Publishing; 1996:681–772
Kooy, 1991, Treatment planning for stereotactic radiosurgery of intra-cranial lesions, Int. J. Radiat. Oncol. Biol. Phys., 21, 683, 10.1016/0360-3016(91)90687-Y
Graham, 1991, A comparison of techniques for stereotactic radiotherapy by linear accelerator based 3-dimensional dose distributions, Radiother. Oncol., 22, 29, 10.1016/0167-8140(91)90066-P
Cubo, 1997, A comparison of arc based and static mini-multileaf collimator-based radiosurgery plans, Radiother. Oncol., 45, 89, 10.1016/S0167-8140(97)00104-7
Lanig, 1993, Stereotactic radiotherapy of irregular targets, Radiother. Oncol., 28, 241, 10.1016/0167-8140(93)90064-F
Leavitt, 1998, Beam shaping for SRT/SRS, Med. Dosim., 23, 229, 10.1016/S0958-3947(98)00018-1
Tobler, 2000, Optimization of primary jaw settings for stereotactic radiosurgery/radiotherapy, Med. Dosim., 25, 201, 10.1016/S0958-3947(00)00046-7
Chen, 2000, Calculation of x-ray transmission through a multileaf collimator, Med. Phys., 27, 1717, 10.1118/1.1286555
Huq, 1995, Dosimetric characteristics of a commercial multileaf collimator, Med. Phys., 22, 241, 10.1118/1.597461
Boyer, 1992, Clinical dosimetry for implementation of a multileaf collimator, Med. Phys., 19, 1255, 10.1118/1.596757
Gerog, 1997, Dosimetric comparison of an integrated multileaf-collimator versus a conventional collimator, Phys. Med. Biol., 42, 2285, 10.1088/0031-9155/42/11/020
Palta, 1996, Dosimetric considerations for a multileaf collimator system, Med. Phys., 23, 1219, 10.1118/1.597678
Xia, 1999, Physical characteristics of a miniature multileaf collimator, Med. Phys., 26, 65, 10.1118/1.598478
Meeks, 1999, Dosimetric characteristics of a double-focused miniature multileaf collimator, Med. Phys., 26, 729, 10.1118/1.598579
Wurm, 1999, Commissioning of a micro-multileaf collimator for conformal stereotactic radiosurgery and radiotherapy, Front. Radiat. Ther. Oncol., 33, 64, 10.1159/000061247
Georg, 1999, Commissioning of a micro-multileaf collimator, Front. Radiat. Ther. Oncol., 33, 51, 10.1159/000061246
Loi, 1998, Design and characterization of a dynamic multileaf collimator, Phys. Med. Biol., 43, 3149, 10.1088/0031-9155/43/10/033
Pasquino, 2001, Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformal radiotherapy, Radiol. Med. (Torino), 101, 187
Stasi, 1999, Dosimetric characterization of a multileaf collimator, Radiol. Med. (Torino), 97, 382
Corvo, 1997, The application of the multileaf collimator in radiotherapy, Radiol. Med. (Torino), 94, 512
Stasi, 2001, Effective penumbra and scalloping effect, Tumori, 87, 30, 10.1177/030089160108700108
Azcoma, 2002, Quality assurance in IMRT, Med. Phys., 29, 269, 10.1118/1.1446110
Morita, 1999, Risk of injury to cranial nerves after gamma knife radiosurgery for skull based meningiomas, J. Neurosurgery., 90, 42, 10.3171/jns.1999.90.1.0042