Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy

Medical Dosimetry - Tập 29 - Trang 72-79 - 2004
Matt Tobler1, Dennis D Leavitt1, Gordon Watson1
1University of Utah Health Science Center, Department of Radiation Oncology, Salt Lake City, UT, USA

Tài liệu tham khảo

Columbo, 1985, External stereotactic irradiation by a linear accelerator, Neurosurgery, 16, 154, 10.1227/00006123-198502000-00005 Hartmann, 1985, Cerebral irradiation therapy using moving field irradiation at a linear accelerator facility, Int. J. Radiat. Oncol. Biol. Phys., 11, 1185, 10.1016/0360-3016(85)90068-9 Winston, 1988, Linear accelerator as a neurosurgical tool for stereotactic radiosurgery, Neurosurgery, 22, 454, 10.1227/00006123-198803000-00002 Lutz, 1988, A system for stereotactic radiosurgery with a linear accelerator, Int. J. Radiat. Oncol. Biol. Phys., 14, 373, 10.1016/0360-3016(88)90446-4 Maitz, 1998, Treatment planning of stereotactic convergent gamma-ray irradiation using Co-60 sources, Med. Dosim., 23, 169, 10.1016/S0958-3947(98)00022-3 Kooy, H.M.; Bellerive, M.R.; Loeffler, J.S. Teletherapy: Present and future, Proceedings of the 1996 AAPM Summer School. In: Mackie, R.T.; Palta, J.R., editors. Stereotactic Radiotherapy. Madison: Advanced Medical Publishing; 1996:681–772 Kooy, 1991, Treatment planning for stereotactic radiosurgery of intra-cranial lesions, Int. J. Radiat. Oncol. Biol. Phys., 21, 683, 10.1016/0360-3016(91)90687-Y Graham, 1991, A comparison of techniques for stereotactic radiotherapy by linear accelerator based 3-dimensional dose distributions, Radiother. Oncol., 22, 29, 10.1016/0167-8140(91)90066-P Cubo, 1997, A comparison of arc based and static mini-multileaf collimator-based radiosurgery plans, Radiother. Oncol., 45, 89, 10.1016/S0167-8140(97)00104-7 Lanig, 1993, Stereotactic radiotherapy of irregular targets, Radiother. Oncol., 28, 241, 10.1016/0167-8140(93)90064-F Leavitt, 1998, Beam shaping for SRT/SRS, Med. Dosim., 23, 229, 10.1016/S0958-3947(98)00018-1 Tobler, 2000, Optimization of primary jaw settings for stereotactic radiosurgery/radiotherapy, Med. Dosim., 25, 201, 10.1016/S0958-3947(00)00046-7 Chen, 2000, Calculation of x-ray transmission through a multileaf collimator, Med. Phys., 27, 1717, 10.1118/1.1286555 Huq, 1995, Dosimetric characteristics of a commercial multileaf collimator, Med. Phys., 22, 241, 10.1118/1.597461 Boyer, 1992, Clinical dosimetry for implementation of a multileaf collimator, Med. Phys., 19, 1255, 10.1118/1.596757 Gerog, 1997, Dosimetric comparison of an integrated multileaf-collimator versus a conventional collimator, Phys. Med. Biol., 42, 2285, 10.1088/0031-9155/42/11/020 Palta, 1996, Dosimetric considerations for a multileaf collimator system, Med. Phys., 23, 1219, 10.1118/1.597678 Xia, 1999, Physical characteristics of a miniature multileaf collimator, Med. Phys., 26, 65, 10.1118/1.598478 Meeks, 1999, Dosimetric characteristics of a double-focused miniature multileaf collimator, Med. Phys., 26, 729, 10.1118/1.598579 Wurm, 1999, Commissioning of a micro-multileaf collimator for conformal stereotactic radiosurgery and radiotherapy, Front. Radiat. Ther. Oncol., 33, 64, 10.1159/000061247 Georg, 1999, Commissioning of a micro-multileaf collimator, Front. Radiat. Ther. Oncol., 33, 51, 10.1159/000061246 Loi, 1998, Design and characterization of a dynamic multileaf collimator, Phys. Med. Biol., 43, 3149, 10.1088/0031-9155/43/10/033 Pasquino, 2001, Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformal radiotherapy, Radiol. Med. (Torino), 101, 187 Stasi, 1999, Dosimetric characterization of a multileaf collimator, Radiol. Med. (Torino), 97, 382 Corvo, 1997, The application of the multileaf collimator in radiotherapy, Radiol. Med. (Torino), 94, 512 Stasi, 2001, Effective penumbra and scalloping effect, Tumori, 87, 30, 10.1177/030089160108700108 Azcoma, 2002, Quality assurance in IMRT, Med. Phys., 29, 269, 10.1118/1.1446110 Morita, 1999, Risk of injury to cranial nerves after gamma knife radiosurgery for skull based meningiomas, J. Neurosurgery., 90, 42, 10.3171/jns.1999.90.1.0042