Optimal excitation wavelengths for discrimination of cervical neoplasia

IEEE Transactions on Biomedical Engineering - Tập 49 Số 10 - Trang 1102-1111 - 2002
S.K. Chang1, M. Follen2, A. Malpica3, U. Utzinger4, G. Staerkel3, D. Cox5, E. Neely Atkinson6, C. MacAulay7, R. Richards-Kortum1
1Electrical and Computer Engineering Department, University of Texas, Austin, Austin, TX, USA
2Biomedical Engineering Center, University of Texas M.D. Anderson Cancer Center, Houston, TX, USA
3Department of Pathology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
4Biomedical Engineering Department, University of Arizona Tucson, Tucson, AZ, USA
5Department of Statistics, Rice University, Houston, TX, USA.
6Department of Biomathematics, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
7Department of Cancer Imaging, British Columbia Cancer Agency, Vancouver, BC, Canada

Tóm tắt

Fluorescence spectroscopy has shown promise for the in vivo, real-time detection of cervical neoplasia. However, selection of excitation wavelength has in the past been based on in vitro studies and the availability of light sources. The goal of this study was to determine optimal excitation wavelengths for in vivo detection of cervical neoplasia. Fluorescence excitation-emission matrices (EEMs) were measured in vivo from 351 sites in 146 patients. Data were analyzed in pairs of diagnostic classes to determine which combination of excitation wavelengths yields classification algorithms with the greatest sensitivity and specificity. We find that 330-340-, 350-380-, and 400-450-nm excitation yield the best performance. The sensitivity and specificity for discrimination of squamous normal tissue and high-grade squamous intraepithelial lesion (HGSIL) were 71 % and 77 % on cross validation using three excitation wavelengths. These results are comparable with those found in earlier in vivo studies; however, in this study we find that the proportion of samples which are HGSIL influences performance. Furthermore stratification of samples within low-grade squamous intraepithelial lesion and HGSIL also appears to influence diagnostic performance. Future diagnostic studies should be carried out at these excitation wavelengths in larger groups so that data can be stratified by diagnostic subcategory, age and menopausal status. Similarly, large studies should be done in screening populations.

Từ khóa

#Neoplasms #In vivo #Fluorescence #Sensitivity and specificity #Lesions #Spectroscopy #In vitro #Light sources #Wavelength measurement #Data analysis

Tài liệu tham khảo

10.1046/j.1526-0976.2001.005002065.x 10.1002/lsm.1900130609 10.1002/lsm.1900120111 10.1002/(SICI)1096-9101(1997)21:2<166::AID-LSM8>3.0.CO;2-O 10.1366/0003702991946695 10.1364/AO.35.005211 zuclich, 1994, rapid noninvasive optical characterization of the human lens, Lasers Life Sci, 6, 39 10.1016/S0029-7844(97)00623-6 10.1007/978-1-4757-1942-0 10.1562/0031-8655(2000)072<0103:OEWFIV>2.0.CO;2 10.1016/S0029-7844(98)00006-4 10.1016/S0029-7844(99)00408-1 10.1111/j.1751-1097.1996.tb03130.x ramanujam, 1994, <emph>in vivo </emph> diagnosis of cervical intraepithelial neoplasia using 337-nm-excited laser-induced fluorescence, Proc Nat Acad Sci USA, 91, 10 193, 10.1073/pnas.91.21.10193 10.1046/j.1526-0976.1999.08109.x 10.1002/(SICI)1096-9101(1996)19:1<63::AID-LSM8>3.0.CO;2-O 10.1001/jama.1994.03510470070037 10.1001/jama.1989.03420050087046 furlong, 1998, Industrial Roundtable OSA Spring Topical Meeting on Biomedical Optical Spectroscopy and Diagnostics 10.1002/1096-9101(2001)28:1<56::AID-LSM1017>3.0.CO;2-L 10.1002/(SICI)1096-9101(1996)19:1<46::AID-LSM7>3.0.CO;2-Q 10.1002/(SICI)1096-9101(1999)25:3<237::AID-LSM8>3.3.CO;2-6 10.1366/0003702981944751 dillon, 1984, Multivariate Analysis Methods and Applications mitchell, 1994, the natural history of cin: an argument for intermediate endpoint biomarkers, Cancer Epidemiol Biomarkers Prevention, 3, 619 lachenbruch, 1975, Discriminant Analysis