On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework
Tóm tắt
Từ khóa
Tài liệu tham khảo
Sureshbabu W, Mawlawi O: PET/CT imaging artifacts. J Nucl Med Technol 2005, 33: 156-161. quiz 63-4 quiz 63-4
Guerra L, De Ponti E, Elisei F, Bettinardi V, Landoni C, Picchio M, Gilardi MC, Versari A, Fioroni F, Dziuk M, Koza M, Ahond-Vionnet R, Collin B, Messa C: Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions. Eur J Nucl Med Mol Imaging 2012, 39: 1381-1390. doi:10.1007/s00259-012-2148-2
Papathanassiou D, Becker S, Amir R, Meneroux B, Liehn JC: Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source. Eur J Nucl Med Mol Imaging 2005, 32: 1422-1428. doi:10.1007/s00259-005-1868-y
Pevsner A, Nehmeh SA, Humm JL, Mageras GS, Erdi YE: Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study. Med Phys 2005, 32: 2358-2362. 10.1118/1.1943809
Lupi A, Zaroccolo M, Salgarello M, Malfatti V, Zanco P: The effect of 18 F-FDG-PET/CT respiratory gating on detected metabolic activity in lung lesions. Ann Nucl Med 2009, 23: 191-196. doi:10.1007/s12149-008-0225-1
Liu C, Pierce LA 2nd, Alessio AM, Kinahan PE: The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Phys Med Biol 2009, 54: 7345-7362. doi:10.1088/0031-9155/54/24/007
Callahan J, Kron T, Schneider-Kolsky M, Hicks RJ: The clinical significance and management of lesion motion due to respiration during PET/CT scanning. Cancer Imaging 2011, 11: 224-236. doi:10.1102/1470-7330.2011.0031
Daou D: Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny. Eur J Nucl Med Mol Imaging 2008, 35: 1961-1970. doi:10.1007/s00259-008-0931-x
Wallach D, Lamare F, Kontaxakis G, Visvikis D: Super-resolution in respiratory synchronized positron emission tomography. IEEE Trans Med Imaging 2012, 31: 438-448. doi:10.1109/TMI.2011.2171358
Liu C, Alessio A, Pierce L, Thielemans K, Wollenweber S, Ganin A, Kinahan P: Quiescent period respiratory gating for PET/CT. Med Phys 2010, 37: 5037-5043. 10.1118/1.3480508
Bailey DL, Kalemis A: Externally triggered gating of nuclear medicine acquisitions: a useful method for partitioning data. Phys Med Biol 2005, 50: N55-N62. doi:10.1088/0031-9155/50/7/N02
Werner MK, Parker JA, Kolodny GM, English JR, Palmer MR: Respiratory gating enhances imaging of pulmonary nodules and measurement of tracer uptake in FDG PET/CT. AJR Am J Roentgenol 2009, 193: 1640-1645. doi:10.2214/AJR.09.2516
Nagamachi S, Wakamatsu H, Kiyohara S, Fujita S, Futami S, Arita H, Nishii R, Tamura S, Kawai K: Usefulness of a deep-inspiration breath-hold 18 F-FDG PET/CT technique in diagnosing liver, bile duct, and pancreas tumors. Nucl Med Commun 2009, 30: 326-332. doi:10.1097/MNM.0b013e3283298f78
Torizuka T, Tanizaki Y, Kanno T, Futatsubashi M, Yoshikawa E, Okada H, Ouchi Y: Single 20-second acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer. J Nucl Med 2009, 50: 1579-1584. doi:10.2967/jnumed.109.064246
Büther F, Ernst I, Dawood M, Kraxner P, Schäfers M, Schober O, Schäfers KP: Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography. Eur J Nucl Med Mol Imaging 2010, 37: 2315-2327. doi:10.1007/s00259-010-1533-y
Schleyer PJ, O’Doherty MJ, Marsden PK: Extension of a data-driven gating technique to 3D, whole body PET studies. Phys Med Biol 2011, 56: 3953-3965. 10.1088/0031-9155/56/13/013
Bundschuh RA, Martinez-Moller A, Essler M, Nekolla SG, Ziegler SI, Schwaiger M: Local motion correction for lung tumours in PET/CT-first results. Eur J Nucl Med Mol Imaging 2008, 35: 1981-1988. 10.1007/s00259-008-0868-0
Kesner AL, Abourbeh G, Mishani E, Chisin R, Tshori S, Freedman N: Gating, enhanced gating, and beyond: information utilization strategies for motion management, applied to preclinical PET. EJNMMI Res 2013, 3: 29. doi:10.1186/2191-219X-3-29
Klein GJ, Reutter BW, Botvinick EH, Budinger TF, Huesman RH: Fine-scale motion detection using intrinsic list mode PET information. In Proceedings of the IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA’01). IEEE Computer Society; 2001:71.
Schleyer P, O’Keefe G, Scott A: Data driven motion correction for nuclear imaging. Google Patents; 2005.
Kesner A, Dahlbom M, Czernin J, Silverman DH: Respiratory gated PET based on time activity curve analysis. J Nucl Med meeting abstracts 2007, 48: 416P.
He J, O’Keefe GJ, Jones G, Saunder T, Gong SJ, Moshi G, Scott AM: Evaluation of Geometrical Sensitivity for Respiratory Motion Gating by GATE and NCAT Simulation. In 29th Annual International Conference of the IEEE. Engineering in Medicine and Biology Society (EMBS); 2007:4165-4168.
Schleyer PJ, O’Doherty MJ, Barrington SF, Marsden PK: Retrospective data-driven respiratory gating for PET/CT. Phys Med Biol 2009, 54: 1935-50. 10.1088/0031-9155/54/7/005
Kesner AL, Bundschuh RA, Detorie NC, Dahlbom M, Ziegler SI, Czernin J, Silverman DH: Respiratory gated PET derived in a fully automated manner from raw PET data. IEEE Trans Nucl Sci 2009, 56: 677-686.
Buther F, Dawood M, Stegger L, Wubbeling F, Schafers M, Schober O, Schafers KP: List mode-driven cardiac and respiratory gating in PET. J Nucl Med 2009, 50: 674-681. doi:10.2967/jnumed.108.059204
Kesner AL, Kuntner C: A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods. Med Phys 2010, 37: 5550-5559. 10.1118/1.3483784
Thielemans K, Rathore S, Engbrant F, Razifar P: Device-less gating for PET/CT using PCA. In Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE; 2011:3904-10.
Büther F, Ernst I, Hamill J, Eich HT, Schober O, Schäfers M, Schafers KP: External radioactive markers for PET data-driven respiratory gating in positron emission tomography. Eur J Nucl Med Mol Imaging 2013, 40: 602-614. doi:10.1007/s00259-012-2313-7
Schleyer PJ, Thielemans K, Marsden PK: Extracting a Respiratory Signal from Raw Dynamic PET Data that Contain Tracer Kinetics. Seoul: IEEE MIC; 2013.
Dawood M, Büther F, Jiang X, Schäfers KP: Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging 2008, 27: 1164-1175. doi:10.1109/TMI.2008.918321
Grotus N, Reader AJ, Stute S, Rosenwald JC, Giraud P, Buvat I: Fully 4D list-mode reconstruction applied to respiratory-gated PET scans. Phys Med Biol 2009, 54: 1705-1721. doi:10.1088/0031-9155/54/6/020
Chun SY, Reese TG, Ouyang J, Guerin B, Catana C, Zhu X, Alpert NM, El Fakhri G: MRI-based nonrigid motion correction in simultaneous PET/MRI. J Nucl Med 2012, 53: 1284-1291. doi:10.2967/jnumed.111.092353
Wurslin C, Schmidt H, Martirosian P, Brendle C, Boss A, Schwenzer NF, Stegger L: Respiratory motion correction in oncologic PET using T1-weighted MR imaging on a simultaneous whole-body PET/MR system. J Nucl Med 2013, 54: 464-471. doi:10.2967/jnumed.112.105296
Bettinardi V, Picchio M, Di Muzio N, Gianolli L, Gilardi MC, Messa C: Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. Radiother Oncol 2010, 96: 311-316. 10.1016/j.radonc.2010.07.014