On the optimization of low-cost FDM 3D printers for accurate replication of patient-specific abdominal aortic aneurysm geometry

Springer Science and Business Media LLC - Tập 4 - Trang 1-10 - 2018
Michael Chung1, Norbert Radacsi1, Colin Robert1, Edward D. McCarthy1, Anthony Callanan2, Noel Conlisk2,3, Peter R. Hoskins2,3, Vasileios Koutsos1
1The School of Engineering, Institute for Materials and Processes, The University of Edinburgh, Edinburgh, UK
2The School of Engineering, Institute for Bioengineering, The University of Edinburgh, Edinburgh, UK
3Centre for Cardiovascular Sciences, The University of Edinburgh, Edinburgh, UK

Tóm tắt

There is a potential for direct model manufacturing of abdominal aortic aneurysm (AAA) using 3D printing technique for generating flexible semi-transparent prototypes. A patient-specific AAA model was manufactured using fused deposition modelling (FDM) 3D printing technology. A flexible, semi-transparent thermoplastic polyurethane (TPU), called Cheetah Water (produced by Ninjatek, USA), was used as the flexible, transparent material for model manufacture with a hydrophilic support structure 3D printed with polyvinyl alcohol (PVA). Printing parameters were investigated to evaluate their effect on 3D–printing precision and transparency of the final model. ISO standard tear resistance tests were carried out on Ninjatek Cheetah specimens for a comparison of tear strength with silicone rubbers. It was found that an increase in printing speed decreased printing accuracy, whilst using an infill percentage of 100% and printing nozzle temperature of 255 °C produced the most transparent results. The model had fair transparency, allowing external inspection of model inserts such as stent grafts, and good flexibility with an overall discrepancy between CAD and physical model average wall thicknesses of 0.05 mm (2.5% thicker than the CAD model). The tear resistance test found Ninjatek Cheetah TPU to have an average tear resistance of 83 kN/m, higher than any of the silicone rubbers used in previous AAA model manufacture. The model had lower cost (4.50 GBP per model), shorter manufacturing time (25 h 3 min) and an acceptable level of accuracy (2.61% error) compared to other methods. It was concluded that the model would be of use in endovascular aneurysm repair planning and education, particularly for practicing placement of hooked or barbed stents, due to the model’s balance of flexibility, transparency, robustness and cost-effectiveness.

Tài liệu tham khảo

Shimizu K, Mitchell RN, Libby P. Inflammation and cellular immune responses in abdominal aortic aneurysms. Arterioscler Thromb Vasc Biol. 2006;26:987–94. Vorp DA. Biomechanics of abdominal aortic aneurysms. J Biomech. 2009;40:1887–902. Study Investigators TM. Aortic Wall Inflammation Predicts Abdominal Aortic Aneurysm Expansion, Rupture and Need for Surgical Repair. Circulation [Internet]. 2017 [cited 2017 Aug 21]; Available from: http://circ.ahajournals.org/content/early/2017/07/13/CIRCULATIONAHA.117.028433.short Assar AN, Zarins CK. Ruptured abdominal aortic aneurysm: a surgical emergency with many clinical presentations. Postgrad. Med. J. 2009, 85:268–73. UK Small Aneurysm Trial Participants. Mortality results for randomised controlled trial of early elective surgery or ultrasonographic surveillance for small abdominal aortic aneurysms. Lancet [Internet]. 1998;352:1649–1655. Available from: http://www.ncbi.nlm.nih.gov/pubmed/9853436 Lall P, Gloviczki P, Agarwal G, Duncan AA, Kalra M, Hoskin T, et al. Comparison of EVAR and open repair in patients with small abdominal aortic aneurysms: Can we predict results of the PIVOTAL trial? J. Vasc. Surg. [Internet]. The Society for Vascular Surgery; 2009;49:52–9. Available from: https://doi.org/10.1016/j.jvs.2008.07.085 See KWM, Chui KH, Chan WH, Wong KC, Chan YC. Evidence for endovascular simulation training: a systematic review. Eur. J. Vasc. Endovasc. Surg. [internet]. Elsevier Ltd; 2016;51:441–51. Available from: https://doi.org/10.1016/j.ejvs.2015.10.011 Saratzis A, Calderbank T, Sidloff D, Bown MJ, Davies RS. Role of simulation in endovascular aneurysm repair (EVAR) training: a preliminary study. Eur. J. Vasc. Endovasc. Surg. [internet]. Elsevier Ltd; 2017;53:193–8. Available from: https://doi.org/10.1016/j.ejvs.2016.11.016 Mafeld S, Nesbitt C, McCaslin J, Bagnall A, Davey P, Bose P, et al. Three-dimensional (3D) printed endovascular simulation models: a feasibility study. Ann. Transl. Med. [Internet]. 2017;5:42–42. Available from: http://atm.amegroups.com/article/view/13631/13916 Torres IO, De Luccia N. A simulator for training in endovascular aneurysm repair: the use of three dimensional printers. Eur. J. Vasc. Endovasc. Surg. [internet]. Elsevier Ltd; 2017;54:247–53. Available from: https://doi.org/10.1016/j.ejvs.2017.05.011 Deplano V, Meyer C, Guivier-Curien C, Bertrand E. New insights into the understanding of flow dynamics in an in vitro model for abdominal aortic aneurysms. Med. Eng. Phys. [Internet]. Institute of Physics and Engineering in Medicine; 2013;35:800–9. Available from: http://linkinghub.elsevier.com/retrieve/pii/S1350453312002378 Antón R, Chen C-Y, Hung M-Y, Finol EA, Pekkan K. Experimental and computational investigation of the patient-specific abdominal aortic aneurysm pressure field. Comput. Methods Biomech. Biomed. Engin. [Internet]. Taylor & Francis; 2015;18:981–92. Available from: http://www.scopus.com/inward/record.url?eid=2-s2.0-84918520150&partnerID=tZOtx3y1 Doyle BJ. Rupture behaviour of abdominal aortic Aneurysms : a computational and experimental investigation. 2009; Corbett TJ, Callanan A, O’Donnell MR, McGloughlin TM. An improved methodology for investigating the parameters influencing migration resistance of abdominal aortic stent-grafts. J Endovasc Ther. 2010;17:95–107. Kono K, Shintani A, Okada H, Terada T. Preoperative simulations of endovascular treatment for a cerebral aneurysm using a patient-specific vascular silicone model. Neurol. Med. Chir. (Tokyo). [internet]. 2013;53:347–51. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23708228. Lermusiaux P, Leroux C, Tasse JC, Castellani L, Martinez R. Aortic aneurysm: construction of a life-size model by rapid prototyping. Ann Vasc Surg. 2001;15:131–5. Doyle BJ, Morris LG, Callanan A, Kelly P, Vorp DA, McGloughlin TM. 3D Reconstruction and Manufacture of Real Abdominal Aortic Aneurysms: From CT Scan to Silicone Model. J. Biomech. Eng. [Internet]. 2008;130:34501. Available from: http://biomechanical.asmedigitalcollection.asme.org/article.aspx?articleid=1475520 Tam MDBS, Laycock SD, Brown JRI, Jakeways M. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy. J Endovasc Ther [Internet] 2013;20:863–7. Available from: http://jet.sagepub.com/lookup/doi/10.1583/13-4450MR.1 Ho D, Squelch A, Sun Z. Modelling of aortic aneurysm and aortic dissection through 3D printing. J Med Radiat Sci. 2017;64:10–7. Cloonan AJ, Shahmirzadi D, Li RX, Doyle BJ, Konofagou EE, McGloughlin TM. 3D–Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications. 3D Print. Addit. Manuf. [Internet]. 2014;1:14–23. Available from: http://online.liebertpub.com/doi/10.1089/3dp.2013.0010 Demehri S, Signorelli J, Kumamaru KK, Wake N, George E, Hanley M, et al. Volumetric quantification of type II endoleaks: an indicator for aneurysm sac growth following endovascular abdominal aortic aneurysm repair. Radiology. 2014;271:282–90. Chepelev L, Hodgdon T, Gupta A, Wang A, Torres C, Krishna S, et al. Medical 3D printing for vascular interventions and surgical oncology: a primer for the 2016 radiological society of North America (RSNA) hands-on course in 3D printing. 3D Print. Med. [Internet]. 3D Printing in Medicine; 2015;2:5. Available from: http://threedmedprint.springeropen.com/articles/10.1186/s41205-016-0008-6 Bangeas P, Voulalas G, Ktenidis K. Rapid prototyping in aortic surgery. Interact Cardiovasc Thorac Surg. 2016;22:513–4. Conlisk N, Geers AJ, McBride OMB, Newby DE, Hoskins PR. Patient-specific modelling of abdominal aortic aneurysms: the influence of wall thickness on predicted clinical outcomes. Med Eng Phys Elsevier Ltd; 2016;38:526–537. Abd El-Fattah MY, Rashad HM, Kashef NA, El Ebiary MA. Evaluation of two different reinforcing materials used with silicone auricular prostheses. Tanta Dent. J. [Internet]. 2013;10:31–8. Available from: http://linkinghub.elsevier.com/retrieve/pii/S1687857413000024 Lopour P, Plichta Z, Volfová Z, Hron P, Vondráček P. Silicone rubber-hydrogel composites as polymeric biomaterials. IV. Silicone matrix-hydrogel filler interaction and mechanical properties. Biomaterials. 1993;14:1051–5. Aziz T, Waters M, Jagger R. Analysis of the properties of silicone rubber maxillofacial prosthetic materials. J Dent. 2003;31:67–74. Kohyama K, Hatakeyama E, Sasaki T, Dan H, Azuma T, Karita K. Effects of sample hardness on human chewing force: a model study using silicone rubber. Arch Oral Biol. 2004;49:805–16. NHS. Information for Patients having a CT Coronary Angiogram. 2015;1–2. Kono K, Shintani A, Okada H, Terada T. Preoperative Simulations of Endovascular Treatment for a Cerebral Aneurysm Using a Patient-Specific Vascular Silicone Model. Neurol. Med. Chir. (Tokyo). 2013;53:347–51.