On the development of low power wearable devices for assessment of physiological vital parameters: a systematic review
Journal of Public Health - Trang 1-16 - 2023
Tóm tắt
Smart wearable devices for continuous monitoring of health conditions have bbecome very important in the healthcare sector to acquire and assess the different physiological parameters. This paper reviews the nature of physiological signals, desired vital parameters, role of smart wearable devices, choices of wearable devices and design considerations for wearable devices for early detection of health conditions. This article provides designers with information to identify and develop smart wearable devices based on the data extracted from a literature survey on previously published research articles in the field of wearable devices for monitoring vital parameters. The key information available in this article indicates that quality signal acquisition, processing and longtime monitoring of vital parameters requires smart wearable devices. The development of smart wearable devices with the listed design criteria supports the developer to design a low power wearable device for continuous monitoring of patient health conditions. The wide range of information gathered from the review indicates that there is a huge demand for smart wearable devices for monitoring health conditions at home. It further supports tracking heath status in the long term via monitoring the vital parameters with the support of wireless communication principles.
Tài liệu tham khảo
Aarts V, Dellimore KH, Wijshoff R, Derkx R, Laar JVD, Muehlsteff J (2017) Performance of An Accelerometer-Based Pulse Presence Detection Approach Compared to A Reference Sensor. Proceedings of the 14th Annual Body Sensor Networks Conference 165–168. https://doi.org/10.1109/BSN.2017.7936033
Ahn J, Ra HK, Yoon HJ, Son SH, Ko J (2020) On-Device Filter Design for Self-Identifying Inaccurate Heart Rate Readings on Wrist-Worn PPG Sensors. IEEE Access 8:184774–184784. https://doi.org/10.1109/ACCESS.2020.3025776
Alicia P (2019) Latest Trends in Medical Monitoring Devices and Wearable Health Technology. Business Insider, India. https://www.businessinsider.com/wearable-technology-healthcare-medical-devices
Allen J (2007) Photoplethysmography and its application in clinical physiological measurement. Physiol Meas 28:R1–R39. https://doi.org/10.1088/0967-3334/28/3/R01
Armagan K, Cigdem E (2011) Perceived Qualities of Smart Wearables: Determinants of User Acceptance. Proceedings of the 2011 Conference on Designing Pleasurable Products and Interfaces 26:1-8. https://doi.org/10.1145/2347504.2347533
Atef M, Wang M, Wang G (2018) A Fully Integrated High-Sensitivity Wide Dynamic Range PPG Sensor with an Integrated Photodiode and an Automatic Dimming Control LED Driver. IEEE Sensors J 18(2):652–659. https://doi.org/10.1109/JSEN.2017.2777740
Boatin AA, Wylie BJ, Goldfarb I, Azevedo R et al (2016) Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study. Telemed J E Health 22(7):564–571. https://doi.org/10.1089/tmj.2015.0173
Boo HY, Sokwoo R (2000) Development of The Ring Sensor for Healthcare Automation. Robot Auton Syst 30(3):273–281. https://doi.org/10.1016/S0921-8890(99)00092-5
Botilias GP, Pappa L, Karvelis P, Stylios C (2022) Tracking Individuals’ Health Using Mobile Applications and Machine Learning. South-East Europe Design Automation Computer Engineering Computer Networks and Social Media Conference 1-6. https://doi.org/10.1109/SEEDA-CECNSM57760.2022.9932927
Brusco M, Nazeran H (2005) Development of an Iintelligent PDA-Based Wearable Digital Phonocardiograph. Proc. 27th Annual International Conference IEEE EMBS 3506–3509. https://doi.org/10.1109/IEMBS.2005.1617235
Buller MJ, Tharion WJ, Cheuvront SN et al (2013) Estimation of Human Core Temperature from Sequential Heart Rate Observations. Physiol Meas 34(7):781–798. https://doi.org/10.1088/0967-3334/34/7/781
Cho G (2010) Smart clothing: technology and applications. CRC Press Taylor & Francis, Boca Raton
Dan S, Asim S, Thad S (2008) Application Design for Wearable Computing. Morgan & Claypool, San Rafael
Daniel O, Benjamin NW, Taemie K et al (2009) Sensible organizations: Technology and Methodology for Automatically Measuring Organizational Behavior. IEEE Trans Syst, Man, and Cybernetics-Part B: Cybernetics 39(1):43–55. https://doi.org/10.1109/TSMCB.2008.2006638
Darko K, Nuria O, Mike S, Desney T (2007) Health-OS: A Position Paper. Conference: Proceedings of the 1st ACM SIGMOBILE International Workshop on Systems and Networking Support for Healthcare and Assisted Living Environments. https://doi.org/10.1145/1248054.1248077
David LTW, Jufeng Y, Yongfu L, Chacko JD et al (2020) An Integrated Wearable Wireless Vital Signs Biosensor for Continuous Inpatient Monitoring. IEEE Sensors J 20(1):448–462. https://doi.org/10.1109/JSEN.2019.2942099
Dias D, Paulo SCJ (2018) Wearable Health Devices-Vital Sign Monitoring. Systems and Technologies. Sensors (Basel, Switzerland) 18(8):2414. https://doi.org/10.3390/s18082414
Elsherif M, Hassan MU, Yetisen AK, Butt H (2018) Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones. ACS Nano 12(6):5452–5462. https://doi.org/10.1021/acsnano.8b00829
Erika P, Emanuele P, Emanuele R et al (2018) Wearable Heart Rate Monitoring as Stress Response Indicator in Children with Neurodevelopmental Disorder. IEEE Int Symposium Med Measurements Appl 1-5. https://doi.org/10.1109/MeMeA.2018.8438805
Fallow BA, Tarumi T, Tanaka H (2013) Influence of Skin Type and Wavelength on Light Wave Reflectance. J Clin Monit Comput 27(3):313–317. https://doi.org/10.1007/s10877-013-9436-7
Fekr AR, Janidarmian M, Radecka K, Zilic Z (2014) A Medical Cloud-Based Platform for Respiration Rate Measurement and Hierarchical Classification of Breath Disorders. Sensors 4(6):11204–11224. https://doi.org/10.3390/s140611204
Finni T, Hu M, Kettunen P, Vilavuo T, Cheng S (2007) Measurement of EMG Activity with Textile Electrodes Embedded into Clothing. Physiol Meas 28(11):1405–1419. https://doi.org/10.1088/0967-3334/28/11/007
Fletcher RR, Tam S, Omojola O, Redemske R, Kwan J (2011) Wearable Sensor Platform and Mobile Application for Use in Cognitive Behavioral Therapy for Drug Addiction and PTSD. Proceedings International Conferences of the IEEE Engineering in Medicine and Biology Society. (EMBC) 802–1805. https://doi.org/10.1109/IEMBS.2011.6090513
Fu Y, Zhao S, Zhu R (2019) A Wearable Multifunctional Pulse Monitor Using Thermosensation-Based Flexible Sensors. IEEE Trans Biomed Eng 66(5):1412–1421. https://doi.org/10.1109/TBME.2018.2873754
Gaura E, Kemp J, Brusey J (2013) Leveraging Knowledge from Physiological Data: On-Body Heat Stress Risk Prediction with Sensor Networks. IEEE Trans Biomed Circuits Syst 7(6):861–870. https://doi.org/10.1109/TBCAS.2013.2254485
Giovangrandi L, Inan OT, Banerjee D, Kovacs GT (2012) Preliminary Results from BCG and ECG Measurements in the Heart Failure Clinic. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society 3780–3783. https://doi.org/10.1109/EMBC.2012.6346790
Gui H, Liu J (2018) Latest Progresses in Developing Wearable Monitoring and Therapy Systems for Managing Chronic Diseases. Med Phys. https://doi.org/10.48550/arXiv.1802.01747
Guk K, Han G, Lim J, Jeong K, Kang T, Lim EK, Jung J (2019) Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare. Nanomaterials 9(6). https://doi.org/10.3390/nano9060813
Haahr RG et al (2012) An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry. IEEE Trans Biomed Circuits Syst 6(1):45–53. https://doi.org/10.1109/TBCAS.2011.2164247
Haydar O, Orhan O, Yasemin K et al (2020) A Portable Wearable Tele-ECG Monitoring System. IEEE Trans Instrum Meas 69:173–182. https://doi.org/10.1109/TIM.2019.2895484
Hsu Y, Young DJ (2014) Skin-Coupled Personal Wearable Ambulatory Pulse Wave Velocity Monitoring System Using Microelectromechanical Sensors. IEEE Sensors J 14(10):3490–3497. https://doi.org/10.1109/JSEN.2014.2345779
Jegan R, Anusuya KV (2015) Real-Time ECG Peak Detection for Heart Rate Measurement Using Wavelet Packet Transform. Int J Biomed Eng Technol 19(3):244–254. https://doi.org/10.1504/IJBET.2015.072994
Jegan R, Nimi WS (2018) Sensor Based Smart Real Time Monitoring of Patients Conditions Using Wireless Protocol. Int J E-Health Med Commun (IJEHMC), 21. https://doi.org/10.4018/IJEHMC.2018070105
Jung DW, Hwang SH, Lee YJ, Jeong D, Park KS (2017) Apnea–Hypopnea Index Prediction Using Electrocardiogram Acquired During the Sleep-Onset Period. IEEE Trans Biomed Eng 64(2):295–301. https://doi.org/10.1109/TBME.2016.2554138
Kalantar ZK, Ha N, Ou JZ, Berean KJ (2017) Ingestible Sensors. ACS Sens 2(4):468–483. https://doi.org/10.1021/acssensors.7b00045
Katayama K, Chino S et al (2020) Classification of Pulse Wave Signal Measured by FBG Sensor for Vascular Age and Arteriosclerosis Estimation. IEEE Sensors J 20(5):2485–2491. https://doi.org/10.1109/JSEN.2019.2952833
Kiourti A, Psathas KA, Nikita KS (2013) Implantable and Ingestible Medical Devices with Wireless Telemetry Functionalities: A Review of Current Status and Challenges. Bioelectromagnetics 35(1):1–15. https://doi.org/10.1002/bem.21813
Krehel M, Wolf M, Boesel LF, Rossi RM, Bona GL, Scherer LJ (2014) Development of a Luminous Textile for Reflective Pulse Oximetry Measurements. Biomedical Optics Express 5(8):2537–2547. https://doi.org/10.1364/BOE.5.002537
Kroll RR, Boyd JG, Maslove DM (2016) Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study. J Med Internet Res 18(9):253. https://doi.org/10.2196/jmir.6025
Kwangmuk L, Hee YC, Kyeonghwan P et al (2019) A Multi-Functional Physiological Hybrid-Sensing E-Skin Integrated Interface for Wearable IoT Applications. IEEE Trans Biomed Circuits Syst 13(6):1535–1544. https://doi.org/10.1109/TBCAS.2019.2946875
Lee YK, Jo J, Shin (2013) Development and Evaluation of a Wristwatch-Type Photoplethysmography Array Sensor Module. IEEE Sensors J 13(5):1459–1463. https://doi.org/10.1109/JSEN.2012.2235424
Lee BG, Park JH et al (2016a) Smartwatch-Based Driver Vigilance Indicator with Kernel-Fuzzy-C-Means-Wavelet Method. IEEE Sensors J 16(1):242–253. https://doi.org/10.1109/JSEN.2015.2475638
Lee Y, Lee H, Yoo S, Yoo HJ (2016b) Sticker-Type ECG/PPG Concurrent Monitoring System Hybrid Integration of CMOS Soc And Organic Sensor Device. Proc. IEEE 38th Annu. Int Conf Eng Med Biol Soc 2014–2017. https://doi.org/10.1109/EMBC.2016.7591121
Lin R, Kreifeldt JG (2001) Ergonomics in Wearable Computer Design. Int J Ind Ergon 27(4):259–269. https://doi.org/10.1016/S0169-8141(00)00055-X
Lin CL, Chiu WC, Chen FH et al (2020) Fall Monitoring for the Elderly Using Wearable Inertial Measurement Sensors on Eyeglasses. IEEE Sensors Letters 4(6):1–4. https://doi.org/10.1109/LSENS.2020.2996746
Liu Y, Matt P, Giovanni AS (2017) Lab-On-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. ACS Nano 11(10):9614–9635. https://doi.org/10.1021/acsnano.7b04898
Liu H, Fujita D, Zhang L, Suzuki A (2018) Real-Time Pulse Waveform Profiling Algorithm for Wearable Applications. IEEE Access 6:59296–59306. https://doi.org/10.1109/ACCESS.2018.2875548
Long J, Bin G, Jun G et al (2019) Wearable Long-Term Social Sensing for Mental Wellbeing. IEEE Sensors J 19(19):8532–8542. https://doi.org/10.1109/JSEN.2018.2877427
Malcolm E, Alysia C (2012) Critical care: The Eight Vital Signs of Patient Monitoring. British J Nursing (Mark Allen Publishing) PubMed 21(10):621–625. https://doi.org/10.12968/bjon.2012.21.10.621
Massaroni C et al (2020) Respiratory Monitoring During Physical Activities with a Multi-Sensor Smart Garment and Related Algorithms. IEEE Sensors J 20(4):2173–2180. https://doi.org/10.1109/JSEN.2019.2949608
Massaroni C, Tocco JD et al (2020b) Respiratory Monitoring During Physical Activities with a Multi-Sensor Smart Garment and Related Algorithms. IEEE Sensors J 20(4):2173–2180. https://doi.org/10.1109/JSEN.2019.2949608
Melvin A, Jegan (2017) Performance Measures on Blood Pressure and Heart Rate Measurement from PPG Signal for Biomedical Applications. Proceedings of IEEE International Conference on Innovations in Electrical, Electronics, Instrumentation and Media Technology, 31-35. https://doi.org/10.1109/ICIEEIMT.2017.8116856
Mendelson Y, Dao DK, Chon KH (2013) Multi-Channel Pulse Oximetry for Wearable Physiological Monitoring. IEEE Int Conference Body Sens Networks 1-6. https://doi.org/10.1109/BSN.2013.6575518
Merah M, Abdelmalik TA, Larbi BH (2015) R-Peaks Detection Based on Stationary Wavelet Transform. Comput Methods Prog Biomed 121(3):149–160. https://doi.org/10.1016/j.cmpb.2015.06.003
Miao F, Wang X et al (2019) A Wearable Sensor for Arterial Stiffness Monitoring Based on Machine Learning Algorithms. IEEE Sensors J 19(4):1426–1434. https://doi.org/10.1109/JSEN.2018.2880434
Nayak CS, Anilkumar AC (2021) EEG Normal Waveforms. National Library of Medicine. https://www.ncbi.nlm.nih.gov/books/NBK539805/
Nimi WS, Subha HJP, Jegan R (2021) Review on Reliable and Quality Wearable Healthcare Device. Int J Reliable Qual E Healthcare 10(4):1–25. https://doi.org/10.4018/IJRQEH.2021100101
Oura Ring (2017) https://ouraring.com/the-ring/
Peng F, Zhang Z, Gou X et al (2014) Motion Artifact Removal from Photoplethysmographic Signals by Combining Temporally Constrained Independent Component Analysis and Adaptive Filter. Biomed Eng Online 3:50. https://doi.org/10.1186/1475-925X-13-50
Puke S, Suzuki T, Nakayama K, Tanaka H, Minami S (2013) Blood Pressure Estimation from Pulse Wave Velocity Measured on The Chest. Proceedings of the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, Japan 6107–6110. https://doi.org/10.1109/EMBC.2013.6610946
Rosenberg WV, Chanwimalueang T et al (2016) Smart Helmet: Wearable Multichannel ECG and EEG. IEEE J Transl Eng Health Med 4:1–11. https://doi.org/10.1109/JTEHM.2016.2609927
Salvo P, Francesco FD et al (2010) A Wearable Sens Measuring Sweat Rate IEEE Sens J 10(10):1557–1558. https://doi.org/10.1109/JSEN.2010.2046634
Sandulescu V, Andrews S, Ellis D, Bellotto N, Mozos OM (2015) Stress Detection Using Wearable Physiological Sensors. International Work-Conference on The Interplay Between Natural and Artificial Computation 526-532. https://doi.org/10.1007/978-3-319-18914-7_55
Sel K, Ibrahim B, Jafari R (2020) ImpediBands: Body Coupled Bio-Impedance Patches for Physiological Sensing Proof of Concept. IEEE Trans Biomed Circuits Syst 14(4):757–774. https://doi.org/10.1109/TBCAS.2020.2995810
Staff DN (2015) 6 Considerations for Designing a Wearable Device. Available: https://www.designnews.com/6-considerations-designing-wearable-device
Svanaes D (2013) Interaction Design for And with The Lived Body: Some Implications of Merleau-Ponty’s Phenomenology. ACM Trans Comput-Hum Interact 20(1):1–30. https://doi.org/10.1145/2442106.2442114
Taiyang W, Fan W, Chunkai Q et al (2020) A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications. IEEE Internet Things J 7(8):6932–6945. https://doi.org/10.1109/JIOT.2020.2977164
Tamura T, Maeda Y, Sekine M, Yoshida M (2014) Wearable Photoplethysmographic Sensors –Past and Present. Electronics 3(2):282–302. https://doi.org/10.3390/electronics3020282
Tang X, Hu Q, Tang W (2018) A Real-Time QRS Detection System With PR/RT Interval and ST Segment Measurements for Wearable ECG Sensors Using Parallel Delta Modulators. IEEE Trans Biomed Circuits Syst 12(4):751–761. https://doi.org/10.1109/TBCAS.2018.2823275
Teng XF, Zhang YT, Poon CC, Bonato P (2008) Wearable Medical Systems for p-Health. IEEE Rev Biomed Eng 1:62–74. https://doi.org/10.1109/RBME.2008.2008248
Tierney MJ, Tamada JA, Potts RO, Jovanovic L, Garg S (2001) Clinical Evaluation of the GlucoWatch Biographer: A Continual, Non-Invasive Glucose Monitor for Patients with Diabetes. Biosens Bioelectron 16(9–12):621–629. https://doi.org/10.1016/s0956-5663(01)00189-0
Vishal VT, Xiaojun X, Devon B et al (2020) Reliable Breathing Tracking with Wearable Mask Device. IEEE Sensors J 20:5510–5518. https://doi.org/10.1109/jsen.2020.2969635
Volkov MV, Margaryants NB et al (2017) Video Capillaroscopy Clarifies Mechanism of the Photoplethysmographic Waveform Appearance. Sci Rep 7:13298. https://doi.org/10.1038/s41598-017-13552-4
Wilhelm VR, Theerasak C et al (2016) Smart Helmet: Wearable Multichannel ECG and EEG. IEEE J Translational Eng Health Med 4:1–11. https://doi.org/10.1109/JTEHM.2016.2609927
Woo SH, Choi YY, Kim DJ, Bien F, Kim JJ (2014) Tissue-Informative Mechanism for Wearable Non-Invasive Continuous Blood Pressure Monitoring. Sci Rep 4:6618. https://doi.org/10.1038/srep06618
Wu T, Wu F, Qiu C, Redoute JM, Yuce MR (2020) A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications. IEEE Internet Things J 7(8):6932–6945. https://doi.org/10.1109/JIOT.2020.2977164
Xiaohui G, Ying H, Yunong Z et al (2017) Highly Stretchable Strain Sensor Based on Swcnts/CB Synergistic Conductive Network or Wearable Human-Activity Monitoring and Recognition. Smart Mater Struct 26(9):5017. https://doi.org/10.1088/1361-665X/aa79c3
Yang CC, Hsu YL (2010) A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring. Sensors 10(8):7772–7788. https://doi.org/10.3390/s100807772
Yeong JJ, Soon JK (2019) Wearable Sleepcare Kit: Analysis and Prevention of Sleep Apnea Symptoms in Real-Time. IEEE Access 7:60634–60649. https://doi.org/10.1109/ACCESS.2019.2913849
Yilmaz T, Foster R, Hao Y (2010) Detecting Vital Signs with Wearable Wireless Sensors. Sensors 10:10837–10862. https://doi.org/10.3390/s101210837
Yufa X, Huailing Z, Lin X et al (2018) An Automatic Cardiac Arrhythmia Classification System with Wearable Electrocardiogram. IEEE Access 6:16529–16538. https://doi.org/10.1109/ACCESS.2018.2807700
Zephyr B (2016) http://www.zephyranywhere.com
Zhu W, Chen X, Wang Y, Wang (2019) Arrhythmia Recognition and Classification Using ECG Morphology and Segment Feature Analysis. IEEE/ACM Trans Comput Biol Bioinform 16(1):131-138. https://doi.org/10.1109/TCBB.2018.2846611