Nuove prospettive della navigazione protesica dell’anca
Tóm tắt
Từ khóa
Tài liệu tham khảo
DiGioia AM, Jaramaz B, Blakwell M. et al (1998) Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res;355:8–22
Jaramaz B, Di Gioia AM 3rd, Blackwell M, et al (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res354:70–81
Pozzi-Mucelli M, Bassini F (2003) La sostituzione protesica dell’anca computer-assistita con TC pre-operatoria: la nostra esperienza su 60 casi Giorn Ital Ortop Traumat. 29:190–194
Pozzi-Mucelli M, Bassini F, Colombo E (2010) Navigazione nella chirurgia protesica dell’anca Giorn Ital Ortop Traumat 36:72–76
Kelley TC, Swank ML (2009) Role of navigation in total hip arthroplasty. J Bone Joint Surg;91A(Suppl.1):153–158
Parratte S, Argenson JN, Flecher X, et al (2007) Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot;93:238–246
Ybinger T, Kumpan W (2007) Enhanced acetabular component positioning through computer assisted navigation. Int Orthopaedics 31(Suppl.):S35–S38
Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg 7: 99–106
Richolt JA, Effenberger H, Rittmeister ME (2005) How does soft tissue distribution affect anteversion accuracy of the palpation procedure in image-free acetabular cup navigation? An ultrasonographic assessment. Comput Aided Surg 10:87–92.
Lewinnek GE, Lewis JL, Tarr R, et al (1978) Dislocation after total hip-replacement arthroplasties. J Bone Joint Surg 60A:217–220.
Murtha PE, Hafez MA, Jaramaz B, DiGioia AM 3rd (2008) Variations in acetabular anatomy with reference to total hip replacement. J Bone Joint Surg Br. 90:308–313.
Archbold HA, Mockford B, Molloy D, et al (2006) The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability. J Bone Joint Surg 88B:883–886.
Pearce CJ, Sexton SA, Davies DC, et al The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty. Hip Int2008;18:7–10.
Viste A, Chouteau J, Testa R, Chèze L et al (2011) Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty? Orthop Traumatol Surg Res. 97(3):241–245. Epub 2011 Feb 1.
Renkawitz T, Haimerl M, Dohmen L, et al (2011) Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial. BMC Musculoskeletal Disorders, 12:192.
Kalteis T, Handel M, Bäthis H, et al (2006) Imageless navigation for insertion of the acetabular component: is it as accurate as CT-based navigation? J Bone Joint Surg;88B:163–167.
Beckmann J, Stengel D, Tingart M et al (2009) Navigated cup implantation in hip arthroplasty. Acta Orthop. 80(5):538–544.
Peters FM, Greeff R, Goldstein N, Frey CT (2012) Improving Acetabular Cup Orientation in Total Hip Arthroplasty by Using Smartphone Technology. J Arthroplasty. Jan 13. [Epub ahead of print]
Baxter JA, Barlow T, Karthikeyan S. Mayo D, King R (2012) The accuracy of automatic calibration of digital pelvic radiographs using two different scale markers: a comparative study Hip Int;22(1):82–89.