Numerical study of hemolysis induced by shear stress at the junction between aorta and ventricular assistance device outflow graft

International Journal of Heat and Fluid Flow - Tập 95 - Trang 108953 - 2022
Jianfei Song1,2, Louis Marcel1, Mathieu Specklin1, Mickael Lescroart3, Jean-Louis Hébert3, Smaine Kouidri1
1Arts et Metiers Institute of Technology, CNAM, LIFSE, HESAM University, 75013 Paris, France
2Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China
3Institute of Cardiology, Pitié-Salpêtrière Hospital, CHU Pitié-Saplêtrière AP-HP, Sorbonne University, 75013 Paris, France

Tài liệu tham khảo

Armour, 2021, The influence of inlet velocity profile on predicted flow in type B aortic dissection, Biomech. Model. Mechanobiol., 20, 481, 10.1007/s10237-020-01395-4 Assmann, 2012, Pulsatile extracorporeal circulation during on-pump cardiac surgery enhances aortic wall shear stress, J. Biomech., 45, 156, 10.1016/j.jbiomech.2011.09.021 Bäumler, 2020, Fluid-structure interaction simulations of patient-specific aortic dissection, Biomech. Model. Mechanobiol., 19, 1607, 10.1007/s10237-020-01294-8 Bazilevs, 2009, Patient-specific isogeometric fluid-structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device, Comput. Methods Appl. Mech. Eng., 198, 3534, 10.1016/j.cma.2009.04.015 Bonnemain, 2013, Numerical simulation of left ventricular assist device implantations: comparing the ascending and the descending aorta cannulations, Medical Engineering, Physics, 35, 1465 Callington, 2015, Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design, The J. Thoracic Cardiovasc. Surg., 150, 696, 10.1016/j.jtcvs.2015.05.034 Caruso, 2015, A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient-specific aortic model, Internat. J. Num. Methods Biomed. Eng., 31, e02700, 10.1002/cnm.2700 D. Garcia. Application du concept de perte de charge au diagnostic échocardiographique des sténoses aortiques, PhD thesis, 2003. Garon, 2004, Fast three-dimensional numerical hemolysis approximation, Artif. Organs, 28, 1016, 10.1111/j.1525-1594.2004.00026.x Good, 2016, Continuous and pulsatile pediatric ventricular assist device hemodynamics with a viscoelastic blood model, Cardiovasc. Eng. Technol., 7, 23, 10.1007/s13239-015-0252-8 Grigioni, 2005, A novel formulation for blood trauma prediction by a modified power-law mathematical model, Biomech. Model. Mechanobiol., 4, 249, 10.1007/s10237-005-0005-y Groen, 2007, Plaque rupture in the carotid artery is localized at the high shear stress region: A case report, Stroke, 38, 2379, 10.1161/STROKEAHA.107.484766 A. E. Hackmann, M. F. Masood, The patient guide to heart, lung, and esophageal surgery, The Society of Thoracic Surgeons. <https://ctsurgerypatients.org/adult-heart-disease/left-ventricular-assist-device-lvad>. 2018. Inci, 2012, Effect of LVAD outlet graft anastomosis angle on the aortic valve, wall, and flow, ASAIO J., 58, 373, 10.1097/MAT.0b013e3182578b6a Kar, 2005, The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: implantation technique and computer flow modeling, Texas Heart Inst. J., 32, 294 Karmonik, 2014, Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images, Artif. Organs, 38, 142, 10.1111/aor.12132 Kok, 2020, Effects of planar and nonplanar curved flow paths on the hemodynamics of helical conduits for coronary artery bypass grafting: A numerical study, Int. J. Heat Fluid Flow, 86, pp108690, 10.1016/j.ijheatfluidflow.2020.108690 Kumar, 2017, Non-Newtonian and newtonian blood flow in human aorta: A transient analysis, Biomed. Res. (India), 28, 3194 Lee, 2013, Left ventricular assist devices: from the bench to the clinic, Cardiology, 125, 1, 10.1159/000346865 Lescroart, 2020, Pulsatility in ventricular assistance devices: A translational review focused on applied haemodynamics, Arch. Cardiovasc. Dis., 113, 461, 10.1016/j.acvd.2020.03.017 May-Newman, 2004, Effect of LVAD outflow conduit insertion angle on flow through the native aorta, J. Med. Eng. Technol., 28, 105, 10.1080/0309190042000193865 May-Newman, 2006, Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta, ASAIO J., 52, 132, 10.1097/01.mat.0000201961.97981.e9 Mazzitelli, 2016, Numerical prediction of the effect of aortic Left Ventricular Assist Device outflow-graft anastomosis location, Biocybernetics Biomed. Eng., 36, 327, 10.1016/j.bbe.2016.01.005 Middleman, 1972, 5 Owen, 2020, Assessment of surface roughness and blood rheology on local coronary haemodynamics: a multi-scale computational fluid dynamics study, J. R. Soc. Interface, 17, 1, 10.1098/rsif.2020.0327 Segalova, 2012, Computational modeling of shear-based hemolysis caused by renal obstruction, J. Biomech. Eng., 134, 02100, 10.1115/1.4005850 Song, 2021, Numerical study on flow topology and hemodynamics in tortuous coronary artery with symmetrical and asymmetrical stenosis, Biocybern. Biomed. Eng., 41, 142, 10.1016/j.bbe.2020.12.006 Sun, 2020, Computational analyses of aortic blood flow under varying speed CF-LVAD support, Comput. Biol. Med., 127, 104058, 10.1016/j.compbiomed.2020.104058 Tang, 2009, Sites of rupture in human atherosclerotic carotid plaques are associated with high structural stresses: An in vivo MRI-based 3D fluid-structure interaction study, Stroke, 40, 3258, 10.1161/STROKEAHA.109.558676 Taskin, 2012, Evaluation of Eulerian and Lagrangian models for hemolysis estimation, Am. Soc. Artif. Internal Organs., 58, 363, 10.1097/MAT.0b013e318254833b van Wyk, 2015, Non-Newtonian perspectives on pulsatile blood-analog flows in a 180°curved artery model, Phys. Fluids, 27, 071901, 10.1063/1.4923311 Voss, 2010, Cardiopulmonary bypass with physiological flow and pressure curves: pulse is unnecessary!☆, Eur. J. Cardiothorac. Surg., 37, 223, 10.1016/j.ejcts.2009.05.050 Vulliémoz, 2002, Estimation of local aortic elastic properties with MRI, Magn. Reson. Med., 47, 649, 10.1002/mrm.10100 Wang, 2019, Influence of impeller speed patterns on hemodynamic characteristics and hemolysis of the blood pump, Appl. Sci., 9, 4689, 10.3390/app9214689 Wood, 2001, Combined MR imaging and CFD simulation of flow in the human descending aorta, J. Magn. Reson. Imaging, 13, 699, 10.1002/jmri.1098 Zhang, 2016, The hemodynamic effects of the LVAD outflow cannula location on the thrombi distribution in the aorta: A primary numerical study, Comput. Methods Programs Biomed., 133, 217, 10.1016/j.cmpb.2016.05.017