Numerical simulation of formaldehyde distribution characteristics in the high-speed train cabin

Fan Wu1,2, Hang Dong1, Chao Yu2,3, Hengkui Li1, Qingmin Cui4, Renze Xu1,2,3
1Key Laboratory of Traffic Safety on Track, Ministry of Education, School of Traffic & Transportation Engineering, Central South University, Changsha, Hunan, China
2Joint International Research Laboratory of Key Technologies for Rail Traffic Safety, Changsha, Hunan, China
3National & Local Joint Engineering Research Center of Safety Technology for Rail Vehicle, Changsha, Hunan, China
4School of Software, Henan University of Engineering, Zhengzhou, Henan, China

Tóm tắt

The global concern over indoor air pollution in public vehicles has grown significantly. With a focus on enhancing passengers’ comfort and health, this study endeavors to investigate the distribution characteristics of formaldehyde within a high-speed train cabin by employing a computational fluid dynamics (CFD) model which is experimentally validated in a real cabin scenario. The research focuses on analyzing the impact of air supply modes, temperature, relative humidity, and fresh air change rate on the distribution and concentration of formaldehyde. The results demonstrate that the difference in average formaldehyde concentration between the two air supply modes is below 1.3%, but the top air supply mode leads to a higher accumulation of formaldehyde near the sidewalls, while the bottom air supply mode promotes a more uniform distribution of formaldehyde. Furthermore, the temperature, relative humidity, and fresh air change rate are the primary factors affecting formaldehyde concentration levels, but they have modest effects on formaldehyde’s distribution pattern within the cabin. As the temperature and relative humidity increase, the changes in formaldehyde concentrations in response to variations in these factors become more evident. Importantly, the formaldehyde concentration may surpass the standard limit of 0.10 mg/m3 if the fresh air change rate falls below 212 m3/h. This research provides a systematic approach and referenceable results for exploring formaldehyde pollution in high-speed train cabins.

Tài liệu tham khảo

An X (2014). Requirements for limits of hazardous substances in interior materials and indoor air of railway passenger trains. Railway Purchasing and Logistics, 9(8): 58–60. (in Chinese) Aydin I, Colakoglu G, Colak S, et al. (2006). Effects of moisture content on formaldehyde emission and mechanical properties of plywood. Building and Environment, 41: 1311–1316. Chen X, Zhang G, Zhang Q, et al. (2011). Mass concentrations of BTEX inside air environment of buses in Changsha, China. Building and Environment, 46: 421–427. EN 13129 (2016). Railway applications—Air conditioning for main line rolling stock—Comfort parameters and type tests. UK: BSI Standards Limited. Gao R, Zhang H, Li A, et al. (2021). Research on optimization and design methods for air distribution system based on target values. Building Simulation, 14: 721–735. Gilbert NL, Guay M, David Miller J, et al. (2005). Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada. Environmental Research, 99: 11–17. Jia X, Zhan X, Zhou X, et al. (2021). Evaluation and optimization strategies of environmental protection performance for passenger seats of EMU. IOP Conference Series: Materials Science and Engineering, 1043: 042005. Jiang Y, Wang G (2016). Study on dustproof structure of air inlet at the bottom of train. Journal of Qingdao University of Technology, 37(1): 72–76. (in Chinese) Konstantinov M, Schmeling D, Wagner C (2023). Numerical simulation of the aerosol formation and spreading in an air-conditioned train compartment. Journal of Aerosol Science, 170: 106139. Kumar A, Singh BP, Punia M, et al. (2014). Determination of volatile organic compounds and associated health risk assessment in residential homes and hostels within an academic institute, New Delhi. Indoor Air, 24: 474–483. Lateb M, Masson C, Stathopoulos T, et al. (2013). Comparison of various types of k-ε models for pollutant emissions around a two-building configuration. Journal of Wind Engineering and Industrial Aerodynamics, 115: 9–21. Li X, Wu F, Tao Y, et al. (2019). Numerical study of the air flow through an air-conditioning unit on high-speed trains. Journal of Wind Engineering and Industrial Aerodynamics, 187: 26–35. Liang W, Gao P, Guan J, et al. (2012). Modeling volatile organic compound (VOC) concentrations due to material emissions in a real residential unit. Part I: Methodology and a preliminary case study. Building Simulation, 5: 351–357. Lin B, Jia H (2022). Does the development of China’s high-speed rail improve the total-factor carbon productivity of cities? Transportation Research Part D: Transport and Environment, 105: 103230. Liu Z, Nicolai A, Abadie M, et al. (2021). Development of a procedure for estimating the parameters of mechanistic VOC emission source models from chamber testing data. Building Simulation, 14: 269–282. Liu J, Zhang R, Xiong J (2023). Machine learning approach for estimating the human-related VOC emissions in a university classroom. Building Simulation, 16: 915–925. Ma S, Li X, Liu G, et al. (2014). Investigation of air quality in compartments of three electric multiple unit models. Journal of Environmental & Occupational Medicine, 31(3): 207–209. (in Chinese) Malayeri M, Bahri M, Haghighat F, et al. (2022). Impact of air distribution on indoor formaldehyde abatement with/without passive removal material: a CFD modeling. Building and Environment, 212: 108792. Miekisch W, Schubert JK, Noeldge-Schomburg GFE (2004). Diagnostic potential of breath analysis—focus on volatile organic compounds. Clinica Chimica Acta, 347: 25–39. Oh MS, Ahn JH, Kim DW, et al. (2014). Thermal comfort and energy saving in a vehicle compartment using a localized air-conditioning system. Applied Energy, 133: 14–21. Park HS, Ji C, Hong T (2016). Methodology for assessing human health impacts due to pollutants emitted from building materials. Building and Environment, 95: 133–144. Pei J, Zhang J (2011). Critical review of catalytic oxidization and chemisorption methods for indoor formaldehyde removal. HVAC&R Research, 17: 476–503. Qin D, Guo B, Zhou J, et al. (2020). Indoor air formaldehyde (HCHO) pollution of urban coach cabins. Scientific Reports, 10: 332. Schmeling D, Bosbach J (2017). On the influence of sensible heat release on displacement ventilation in a train compartment. Building and Environment, 125: 248–260. Schmeling D, Volkmann A (2020). On the experimental investigation of novel low-momentum ventilation concepts for cooling operation in a train compartment. Building and Environment, 182: 107116. Shi W, Li L, Zhang C, et al. (2020). Effects of sampling bag specifications and sample size on the detection results of volatile organic compounds content by using sampling bag method. Chemical Analysis and Meterage, 29(5): 116–120. (in Chinese) Shih T-H, Liou WW, Shabbir A, et al. (1995). A new k-ε eddy viscosity model for high Reynolds number turbulent flows. Computers & Fluids, 24: 227–238. Tang J, Zhou Z, Chen H, et al. (2021). Laminate design, optimization, and testing of an innovative carbon fiber-reinforced composite sandwich panel for high-speed train. Polymer Composites, 42: 5811–5829. Tao Y, Yang M, Qian B, et al. (2019). Numerical and experimental study on ventilation panel models in a subway passenger compartment. Engineering, 5: 329–336. TB/T 3139 (2021). Limit of harmful substance of non-metallic materials and indoor air for railway locomotive and vehicle. (in Chinese) Wang H, Lin M, Chen Y (2014). Performance evaluation of air distribution systems in three different China railway high-speed train cabins using numerical simulation. Building Simulation, 7: 629–638. Wang B, Wei L, Dong J, et al. (2018). Test method for volatile organic compounds in the interior parts of rail transit vehicle. Urban Mass Transit, 21(11): 21–26, 31. (in Chinese) Wang H, Wang H, Xiong J, et al. (2022). A rapid and robust method to determine the key parameters of formaldehyde emissions from building and vehicle cabin materials: principle, multi-source application and exposure assessment. Journal of Hazardous Materials, 430: 128422. Wu F, Zhou S, Cui Q, et al. (2023). Quantitative measurement and application of droplets on physical surfaces based on LIF technology. Transportation Safety and Environment: tdad030. Xu B, Wu Y, Gong Y, et al. (2016). Investigation of volatile organic compounds exposure inside vehicle cabins in China. Atmospheric Pollution Research, 7: 215–220. Xu R, Qian B, Wu F, et al. (2022a). Dispersion of evaporating droplets in the passenger compartment of high-speed train. Journal of Building Engineering, 48: 104001. Xu R, Wu F, Li X, et al. (2022b). Numerical comparison of ventilation modes on the transmission of coughing droplets in a train compartment. Journal of Wind Engineering and Industrial Aerodynamics, 231: 105240. Yamasawa H, Hirayama T, Kuga K, et al. (2022). Influence of inlet turbulent condition on the formation mechanism of local scalar concentrations. Japan Architectural Review, 5: 691–701. Yesildagli B, Lee SB, Lee J (2023). Temporal variations of volatile organic compounds inside the cabin of a new electric vehicle under different operation modes during winter using proton transfer reaction time-of-flight mass spectrometry. Journal of Hazardous Materials, 453: 131368. Zhang L, Li Y (2012). Dispersion of coughed droplets in a fully-occupied high-speed rail cabin. Building and Environment, 47: 58–66. Zhang J, Guo H, Li M, et al. (2013). Selection of interior materials for railway passenger cars. Railway Purchasing and Logistics, 8(4): 63–64. (in Chinese) Zhang T, Li X, Rao Y, et al. (2020). Removal of formaldehyde in urban office building by the integration of ventilation and photocatalyst-coated window. Sustainable Cities and Society, 55: 102050. Zhao L, Zhou H, Jin Y, et al. (2022). Experimental and numerical investigation of TVOC concentrations and ventilation dilution in enclosed train cabin. Building Simulation, 15: 831–844. Zhou W, Li J, Wen X (2015). Influence of environmental factors on emission of formaldehyde from wood-based panel. Environmental Science and Management, 40(6): 121–124. (in Chinese) Zhu J, Li X, Mie C (2015). Combustion performance of flame-ignited high-speed train seats via full-scale tests. Case Studies in Fire Safety, 4: 39–48. Zhuang R, Li X, Tu J (2014). CFD study of the effects of furniture layout on indoor air quality under typical office ventilation schemes. Building Simulation, 7: 263–275.