Numerical Analysis of Three-dimensional Nanodisk Array–based Surface Plasmon Resonance Biosensors for SARS-CoV-2 Detection

Plasmonics - Tập 18 - Trang 769-779 - 2023
Yan Guo1, Xianglong Su1, Kaihua Wu1, Ken-Tye Yong2
1School of Automation, Hangzhou Dianzi University, Hangzhou, China
2School of Biomedical Engineering, The University of Sydney, Sydney, Australia

Tóm tắt

With continuous mutations of SARS-CoV-2 virus, new highly contagious and fast-spreading variants have emerged, including Delta and Omicron. The popular label-free immunosensor based on surface plasmon resonance (SPR) technique can be used for real-time monitoring of the ligand-analyte or antibody-antigen interactions occurring on the sensor surface. In this work, an SPR-based biosensor combined with a nanodisk array was presented to enhance the sensitivity toward virus detection. The nanodisk arrays were employed to enhance the adsorption of molecules for better detection by increasing the SPR field. Four optimal sensing configurations of silver or gold nanodisks on gold thin films with different aspect ratios were achieved through systematic optimization of all parameters to yield the best sensor performance. The resonance angle can be modulated simply by the aspect ratio of nanodisk array. The sensitivity of the optimized sensors has been improved, and the detection limit is smaller than that of bare gold-based sensor. The multi-jump resonance angle curves at tiny refractive index can clearly distinguish the difference of trace concentrations, which is very important for the accurate detection of trace substances.

Tài liệu tham khảo

Su S, Wong G, Shi W, Liu J, Gao GF (2016) Epidemiology, genetic recombination, and pathogenesis of coronaviruses. Trends Microbiol 24:490–502 Zhu N, Zhang D, Wang W, Li X, Yang B, Song J, Zhao X, Huang B, Shi W, Lu R, Niu P, Zhan F, Ma X, Wang D, Xu W, Wu G, Gao G, Tan W (2020) A novel coronavirus from patients with pneumonia in China, 2019. N Engl J Med 382:727–733 de Wit E, van Doremalen N, Falzarano D, Munster VJ (2016) SARS and MERS: recent insights into emerging coronaviruses. Nat Rev Microbiol 14:523–534 Wrapp D, Wang N, Corbett KS, Goldsmith JA, Hsieh CL, Abiona O, Graham BS, Mclellan JS (2020) Cryo-EM structure of the 2019-nCoV spike in the prefusion conformation. Science 367:1260 Weiss C, Carriere M, Fusco L, Capua I, Regla-Nava JA, Pasquali M, Scott JA, Vitale F, Unal MA, Mattevi C, Bedognetti D, Merkoci A, Tasciotti E, Yilmazer A, Gogotsi Y, Stellacci F, Delogu LG (2020) Toward nanotechnology-enabled approaches against the COVID-19 pandemic. ACS Nano 14:6383–6406 Suzuki R, Yamasoba D, Kimura I, Wang L, Kishimoto M, Ito J, Morioka Y, Nao N, Nasser H, Uriu K (2022) Attenuated fusogenicity and pathogenicity of SARS-CoV-2 omicron variant. Nature 603(7902):700–705 Zhong JF, Weiner LP, Burke K, Taylor CR (2007) Viral RNA extraction for in-the-field analysis. J Virol Methods 144(1–2):98–102 Mulder J, McKinney N, Christopherson C, Sninsky J, Greenfield L, Kwok S (1994) Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection. J Clin Microbiol 32:292–300 Berger A, Braner J, Doerr HW, Weber B (1998) Quantification of viral load: clinical relevance for human immunodeficiency virus, hepatitis B virus and hepatitis C virus infection. Intervirology 41:24–34 Boeckh M, Boivin G (1998) Quantitation of cytomegalovirus: methodologic aspects and clinical applications. Clin Microbiol Rev 11:533–554 Paulij WP, de Wit PLM, Sünnen CMG, van Roosmalen MH, Petersenvan Ettekoven A, Cooreman MP, Heijtink RA (1999) Localization of a unique hepatitis B virus epitope sheds new light on the structure of hepatitis B virus surface antigen. J Gen Virol 80(Pt 8)(12):2121 Butt SA, Maceira VP, McCallen ME, Stellrecht KA (2014) Comparison of three commercial RT-PCR systems for the detection of respiratory viruses. J Clin Virol 61:406–410 Piralla A, Daleno C, Pariani E, Conaldi P, Esposito S, Zanetti A, Baldanti F (2013) Virtual quantification of influenza A virus load by real-time RT-PCR. J Clin Virol Official Publ Pan Am Soc Clin Virol 56(1):65–68 Baac H, Hajós JP, Lee J, Kim D, Kim SJ, Shuler ML (2006) Antibody-based surface plasmon resonance detection of intact viral pathogen. Biotechnol Bioeng 94(4):815–819 Zheng S, Kim DK, Park TJ, Lee SJ, Sang YL (2010) Label-free optical diagnosis of hepatitis B virus with genetically engineered fusion proteins. Talanta 82(2):803–809 Keske A, Atar A, Üstündağ İ, Çağlayan MO (2014) Detection of influenza A by surface plasmon resonance enhanced total internal reflection ellipsometry. J Comput Theor Nanos 11(4):981–986 Kim SA, Byun KM, Kim K, Jang SM, Ma K, Oh Y, Kim D, Kim SG, Shuler ML, Kim SJ (2010) Surface-enhanced localized surface plasmon resonance biosensing of avian influenza DNA hybridization using subwavelength metallic nanoarrays. Nanotechnology 21(35):355503 Yang ZW, Pham TT, Hsu CC, Lien CH, Phan QH (2022) Single-layer-graphene-coated and gold-film-based surface plasmon resonance prism coupler sensor for immunoglobulin G detection. Sensors 22(4):1362 Song W, Wang Y, Wang N, Wang D, Guo J, Fu L, Shi X (2014) Identification of residues on human receptor DPP4 critical for MERS-CoV binding and entry. Virology 471–473:49–53 Park TJ, Hyun MS, Lee HJ, Sang YL, Ko S (2009) A self-assembled fusion protein-based surface plasmon resonance biosensor for rapid diagnosis of severe acute respiratory syndrome. Talanta 79(2):295–301 Lu R, Zhao X, Li J, Niu P, Yang B, Wu H, Wang W, Song H, Huang B, Zhu N, Bi Y, Ma X, Zhan F, Wang L, Hu T, Zhou H, Hu Z, Zhou W, Zhao L, Chen J, Meng Y, Wang J, Lin Y, Yuan J, Xie Z, Ma J, Liu WJ, Wagn D, Xu W, Holmes EC, Gao GF, Wu G, Chen W, Shi W, Tan W (2020) Genomic characterisation and epidemiology of 2019 novel coronavirus: implications for virus origins and receptor binding. Lancet 395:565–574 Chi X, Yan R, Zhang J, Zhang G, Zhang Y, Hao M, Zhang Z, Fan P, Dong Y, Yang Y, Chen Z, Guo Y, Zhang J, Li Y, Song X, Chen Y, Xia L, Fu L, Hou L, Xu J, Yu C, Li J, Zhou Q, Chen W (2020) A neutralizing human antibody binds to the N-terminal domain of the spike protein of SARS-CoV-2. Science 369(6504):650–655 Coronaviridas Study Group of the International Committee on Taxonomy of Viruses (2020) The species severe acute respiratory syndrome-related coronavirus: classifying 2019-nCoV and naming it SARS-CoV-2. Nat Microbiol 5:536–544 Wrapp D, Wang N, Corbett KS, Goldsmith JA, Hsieh CL, Abiona O, Graham BS, McLellan JS (2020) Cryo-EM structure of the 2019-nCoV spike in the prefusion conformation. Science 367(6483):1260–1263 Long QX, Liu BZ, Deng HJ, Wu G, Deng K, Chen Y, Liao P, Qiu J, Lin Y, Cai X, Wang D, Hu Y, Ren J, Tang N, Xu Y, Yu L, Mo Z, Gong F, Zhang X, Tian W, Hu L, Zhang X, Xiang J, Du H, Liu H, Lang C, Luo X, Wu S, Cui X, Zhou Z, Zhu M, Wang J, Xue C, Li X, Wang L, Li Z, Wang K, Niu C, Yang Q, Tang X, Zhang Y, Liu X, Li J, Zhang D, Zhang F, Liu P, Yuan J, Li Q, Hu J, Chen J, Huang A (2020) Antibody responses to SARS-CoV-2 in patients with COVID-19. Nat Med 26:845–848 Letko M, Marzi A, Munster V (2020) Functional assessment of cell entry and receptor usage for SARS-CoV-2 and other lineage B betacoronaviruses. Nat Microbiol 5:562–569 Akib TBA, Mou SF, Rahman MM, Rana MM, Kouzani AZ (2021) Design and numerical analysis of a graphene-coated SPR biosensor for rapid detection of the novel coronavirus. Sensors 21:3491 Uddin SMA, Chowdhury SS, Kabir E (2021) Numerical analysis of a highly sensitive surface plasmon resonance sensor for SARS-CoV-2 detection. Plasmonics 16(6):2025–2037 Moznuzzaman M, Khan I, Islam MR (2021) Nano-layered surface plasmon resonance-based highly sensitive biosensor for virus detection: a theoretical approach to detect SARS-CoV-2. AIP Adv 11(6):065023 Zheng YQ, Bian SM, Rong G (2022) Label-free LSPR-vertical microcavity biosensor for on-site SARS-CoV-2 detection. Biosensors 12(3):151 Shen Y, Zhou J, Liu T, Tao Y, Jiang R, Liu M, Xiao G, Zhu J, Zhou Z, Wang X, Jin C, Wang J (2013) Plasmonic gold mushroom arrays with refractive index sensing figures of merit approaching the theoretical limit. Nat Commun 4:2381 Qiu G, Gai Z, Tao Y, Schmitt J, Kullak-Ublick GA, Wang J (2020) Dual-functional plasmonic photothermal biosensors for highly accurate severe acute respiratory syndrome coronavirus 2 detection. ACS Nano 14:5268–5277 Ta Y, Kajisa T, Ono M, Miyasaka Y, Hasegawa Y, Saito A, Otsuka K, Sakane A, Sasaki T, Yasutomo K, Hamajima R, Kanai Y, Kobayashi T, Matsuura Y, Itonaga M, Yasui T (2022) Ultrasensitive detection of SARS-CoV-2 nucleocapsid protein using large gold nanoparticle enhanced surface plasmon resonance. Sci Rep 12:1060 Ravi Shankaran R, Miura N (2007) Trends in interfacial design for surface plasmon resonance based immunoassays. J Phys D Appl Phys 40(23):7187–7200 Hossain MB, Khan MMR, Rahman MS, Badrudduza SSB, Sabiha MM, Rana MM (2019) Graphene-MoS2-Au-TiO2-SiO2 hybrid SPR biosensor: a new window for formalin detection. J Mater Appl 8(2):51–58 Rahman MS, Hasan M, Rikta KA, Anower MS (2018) A novel graphene coated surface plasmon resonance biosensor with tungsten disulfide (WS2) for sensing DNA hybridization. Opt Mater 75:567–573 Das CM, Guo Y, Yang G, Kang LX, Xu GX, Ho HP, Yong KT (2020) Gold nanorod assisted enhanced plasmonic detection scheme of COVID-19 SARS-CoV-2 spike protein. Adv Theory Simul 3(11):2000185