Nubac Disc Arthroplasty: Preclinical Studies and Preliminary Safety and Efficacy Evaluations

SAS Journal - Tập 1 - Trang 36-45 - 2007
Qi-Bin Bao1, Matthew Songer1, Luis Pimenta2, Dieter Werner3, Alejandro Reyes-Sanchez4, Massimo Balsano5, Umberto Agrillo6, Domagoj Coric7, Kenneth Davenport8, Hansen Yuan9
1Pioneer Surgical Technology, Marquette, Mich
2Santa Rita Hospital, Sao Paulo, Brazil
3Arkade Privatklinik Niederschmalkalden, Breitungen, Germany
4Instituto de Ortopedia, Mexico City, Mexico
5UO Ortopedia Traumatologia, Thiene, Italy
6Ospedale Sandro Pertini, Rome, Italy
7Carolina Neurosurgery and Spine Association, Charlotte, NC
8Orthopedic Surgery Association of Marquette, Marquette
9SUNY Upstate Medical University, Syracuse

Tài liệu tham khảo

Nachemson, 1966, The load on lumbar disks in different positions of the body, Clin Orthop Relat Res, 45, 107, 10.1097/00003086-196600450-00014 Blumenthal, 2005, A prospective, randomized, multicenter Food and Drug Administration investigational device exemptions study of lumbar total disc replacement with the Charité artificial disc versus lumbar fusion Part I: Evaluation of clinical outcomes, Spine, 30, 1565, 10.1097/01.brs.0000170587.32676.0e McAfee, 2005, Spine, 30, 1576, 10.1097/01.brs.0000170561.25636.1c Errico, 2005, Lumbar disc arthroplasty, Clin Orthop Relat Res, 435, 106, 10.1097/01.blo.0000165718.22159.d9 Fernstrom, 1966, Arthroplasty with intercorporal endoprosthesis in herniated disc and in painful disc, Acta Chir Scand Suppl, 357, 154 McKenzie, 1995, Fernstrom intervertebral disc arthroplasty: a long-term evaluation, Ortho Int Ed, 3, 313 International Organization for Standardization. ISO 10993-1 Biological evaluation of medical devices—Part 1: Evaluation and testing. 2003. Available at: http://www.iso.org. Cartwright K, Devine J. Investigation into the effect of g sterilization (200kGy) and accelerated aging on the properties of PEEK-Optima [technical report]. West Conshohocken, Pa: Invibio; 2005. International Organization for Standardization. ISO/DIS 18192-1 Implants for surgery—Wear of total intervertebral spinal disc prostheses—Part 1: Loading and displacement parameters for wear testing and corresponding environmental conditions for tests. 2004. Available at: http://www.iso.org. Fairbank, 2000, The Oswestry Disability Index, Spine, 25, 2940, 10.1097/00007632-200011150-00017 Wright, 2006, Retrieval and wear analyses of ProDisc lumbar disc implants Klara, 2002, Artificial nucleus replacement: clinical experience, Spine, 27, 1374, 10.1097/00007632-200206150-00022 Bertagnoli, 2003, The Anterolateral TransPsoatic Approach (ALPA): a new technique for implanting prosthetic disc-nucleus devices, J Spinal Disord Tech, 16, 398, 10.1097/00024720-200308000-00012 Ozgur, 2006, Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion, Spine J, 6, 435, 10.1016/j.spinee.2005.08.012