Nonlinear control performance assessment in the presence of valve stiction
Tài liệu tham khảo
Bialkowski, 1998, Dreams versus reality: a view from both sides of the gap, Pulp & Paper Canada, 94, 19
Desborough, 2002, Increasing customer value of industrial control performance monitoring: Honeywell’s experience
Joe Qin, 1998, Control performance monitoring—a review and assessment, Computers in Chemical Engineering, 23, 173, 10.1016/S0098-1354(98)00259-2
Harris, 1999, A review of performance monitoring and assessment techniques for univariate and multivariate control systems, Journal of Process Control, 9, 1, 10.1016/S0959-1524(98)00031-6
Huang, 1999
Jelali, 2006, An overview of control performance assessment technology and industrial applications, Control Engineering Practice, 14, 441, 10.1016/j.conengprac.2005.11.005
Scali, 2009, Implementation and validation of a closed loop performance monitoring system
Ruel, 2000, Stiction: the hidden menace, Control Magazine, 13, 69
Horch, 1999, A simple method for detection of stiction in control valves, Control Engineering Practice, 7, 1221, 10.1016/S0967-0661(99)00100-8
Choudhury, 2005, Modelling valve stiction, Chemical Engineering Progress, 13, 641
Choudhury, 2006, Automatic detection and quantification of stiction in control valves, Control Engineering Practice, 14, 1395, 10.1016/j.conengprac.2005.10.003
Thornhill, 2007, Advances and new directions in plant-wide disturbance detection and diagnosis, Control Engineering Practice, 15, 1196, 10.1016/j.conengprac.2006.10.011
Singhal, 2005, A simple method for detecting valve stiction in oscillating control loops, Journal of Process Control, 15, 371, 10.1016/j.jprocont.2004.10.001
Scali, 2008, An improved qualitative shape analysis technique for automatic detection of valve stiction in flow control loops, Control Engineering Practice, 16, 1501, 10.1016/j.conengprac.2008.04.009
Jelali, 2008, Estimation of valve stiction in control loops using separable least-squares and global search algorithms, Journal of Process Control, 18, 632, 10.1016/j.jprocont.2007.12.007
Farenzena, 2009, Valve stiction evaluation using global optimization
Jelali, 2010
Choudhury, 2007, Detection and diagnostics of plant-wide oscillations, Canadian Journal of Chemical Engineering, 85, 208, 10.1002/cjce.5450850209
Horch, 2006, Oscillation diagnosis in control loops—stiction and other causes
Harris, 2007, Controller assessment for a class of nonlinear systems, Journal of Process Control, 17, 607, 10.1016/j.jprocont.2007.01.011
W. Yu, D.I. Wilson, B.R. Young, Control performance assessment in the presence of valve stiction, in: K. Grigoriadis (Ed.), The Eleventh IASTED International Conference on Intelligent Systems and Control, ISC 2008, Orlando, Florida, USA, 16–18 November, 2008, pp. 379–384.
Yu, 2009, Eliminating valve stiction nonlinearities for control performance assessment
Åström, 1970
Box, 1970
Horch, 1999, A modified index for control performance assessment, Journal of Process Control, 9, 475, 10.1016/S0959-1524(99)00031-1
Cleveland, 1979, Robust locally weighted regression and smoothing scatterplots, Journal of the American Statistical Association, 74, 829, 10.2307/2286407
Cleveland, 1988, Locally weighted regression: an approach to regression analysis by local fitting, Journal of the American Statistical Association, 83, 596, 10.2307/2289282
Wilson, 2006, The Black Art of Smoothing, Electrical & Automation Technology, 35
Reinsch, 1971, Smoothing by spline functions. II, Numerische Mathematik, 16, 451, 10.1007/BF02169154
Hinich, 1982, Testing for Gaussianity and linearity of a stationary time series, Journal of Time Series Analysis, 3, 169, 10.1111/j.1467-9892.1982.tb00339.x
Ashley, 1986, A diagnostic test for nonlinear serial dependence in time series fitting errors, Journal of Time Series Analysis, 7, 165, 10.1111/j.1467-9892.1986.tb00500.x
Tong, 1990
Haber, 1999
Ljung, 1987