In the present study, a screen-printed electrode based-sensor with electrochemical detection was developed for rapid and sensitive determination of acetylcholine. At first, the screen-printed carbon electrode was modified by using a magnetic core shell and then was used for voltammetric determination of acetylcholine in ampoule, serum and urine samples. The electrochemical behaviour of acetylcholine at the modified electrode was investigated by cyclic voltammetry. The modified electrode displayed a decrease in the overpotential (ca. 130 mV) and an obvious increase in the peak current compared to the non-modified screen-printed electrode. The results indicated that modified screen-printed electrode enhanced electrocatalytic activity towards the oxidation of acetylcholine. Under optimized conditions, the limit of detection from the experiment of acetylcholine determination was 0.02 µM with acetylcholine concentration in range of 0.1–500.0 µM. The reproducibility of the measurements was tested by recording the responses for 50.0 µM acetylcholine with four different developed sensors prepared on the same manner and the same day. A relative standard deviation value of 4.3% was obtained. Finally, a recovery test is done as a part of accuracy evaluation of the system.
Tài liệu tham khảo
Chauhan N, Pundir CS (2014) Amperometric determination of acetylcholine—a neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode. Biosens Bioelectron 61:1–8
Bolat EO, Tıg GA, Pekyardımcı S (2017) Fabrication of an amperometric acetylcholine esterase-choline oxidase biosensor based on MWCNTs-Fe3O4NPs-CS nanocomposite for determination of acetylcholine. J Electroanal Chem 785:241–248
Yang M, Yang Y, Yang Y, Shen G, Yu R (2005) Microbiosensor for acetylcholine and choline based on electropolymerization/sol–gel derived composite membrane. Anal Chim Acta 530:205–211
Xue W, Cui T (2008) A thin-film transistor based acetylcholine sensor using self-assembled carbon nanotubes and SiO2 nanoparticles. Sens Actuators B 134:981–987
Çevik S, Timur S, Anik U (2012) Biocentri-voltammetric biosensor for acetylcholine and choline. Microchim Acta 179:299–305
Shimomura T, Itoh T, Sumiya T, Mizukami F, Ono M (2009) Amperometric biosensor based on enzymes immobilized in hybrid mesoporous membranes for the determination of acetylcholine. Enzyme Microb Technol 45:443–448
Persike M, Zimmermann M, Klein J, Karas M (2010) Quantitative determination of acetylcholine and choline in microdialysis samples by MALDI-TOF MS. Anal Chem 82:922–929
Yoshida H, Yamada A, Todoroki K, Imakyure O, Nohta H, Yamaguchi M (2009) Liquid chromatographic determination of acetylcholine based on pre-column alkaline cleavage reaction and post-column tris (2,2′-bipyridyl) ruthenium (III) chemiluminescence detection. Luminescence 24:306–310
Patterson TA, Kosh JW (1992) Simultaneous quantitation of arecoline, acetylcholine, and choline in tissue using gas chromatography/electron impact mass spectrometry. Biol Mass Spectrom 21:299–304
Carter N, Trenerry VC (1996) The determination of choline in vitamin preparations, infant formula and selected foods by capillary zone electrophoresis with indirect ultraviolet detection. Electrophoresis 17:1622–1626
Barsoum BN, Watson WM, Mahdi IM, Khalid E (2004) Electrometric assay for the determination of acetylcholine using a sensitive sensor based on carbon paste. J Electroanal Chem 567:277–281
Qian J, Yang X, Jiang L, Zhu C, Mao H, Wang K (2014) Facile preparation of Fe3O4 nanospheres/reduced graphene oxide nanocomposites with high peroxidase-like activity for sensitive and selective colorimetric detection of acetylcholine. Sens Actuators B Chem 201:160–166
Wang CI, Periasamy AP, Chang HT (2013) Photoluminescentc-dots@RGO probe for sensitive and selective detection of acetylcholine. Anal Chem 85:3263–3270
Buiculescu R, Hatzimarinaki M, Chaniotakis N (2010) Biosilicated CdSe/ZnS quantum dots as photoluminescent transducers for acetylcholinesterase-based biosensors. Anal Bioanal Chem 398:3015–3021
Burmeister JJ, Pomerleau F, Huettl P, Gash CR, Werner CE, Bruno JP, Gerhardt GA (2008) Ceramic-based multisite microelectrode arrays for simultaneous measures of choline and acetylcholine in CNS. Biosens Bioelectron 23:1382–1389
Zayats M, Kharitonov AB, Pogorelova SP, Lioubashevski O, Katz E, Willner I (2003) Probing photoelectrochemical processes in Au-CdS nanoparticle arrays by surface plasmon resonance: application for the detection of acetylcholine esterase inhibitors. J Am Chem Soc 125:16006–16014
Zhu W, An YR, Zheng JH, Tang LL, Zhang W, Jin LT, Jiang L (2009) A new microdialysis electrochemical device for in vivo simultaneous determination of acetyl-choline and choline in rat brain treated with N-methyl-(R)-salsolinol. Biosens Bioelectron 24:3594–3599
Anithaa AC, Asokan K, Sekar C (2018) Low energy nitrogen ion beam implanted tungsten trioxide thin films modified indium tin oxide electrode based acetylcholine sensor. J Taiwan Inst Chem Eng 84:11–18
Mohammadi SZ, Beitollahi H, Jasemi M, Akbari A (2015) Nanomolar determination of methyldopa in the presence of large amounts of hydrochlorothiazide using a carbon paste electrode modified with graphene oxide nanosheets and 3-(4′-amino-3′-hydroxy-biphenyl-4-yl)acrylic acid. Electroanalysis 27:2421–2430
Beitollahi H, Ghofrani Ivari S, Torkzadeh Mahani M (2016) Voltammetric determination of 6-thioguanine and folic acid using a carbon paste electrode modified with ZnO-CuO nanoplates and modifier. Mater Sci Eng C 69:128–133
Mohammadi SZ, Beitollahi H, Hassanzadeh M (2018) Voltammetric determination of tryptophan using a carbon paste electrode modified with magnesium core shell nanocomposite and ionic liquids. Anal Bioanal Chem Res 5:55–65
Jahani Sh, Beitollahi H (2016) Selective detection of dopamine in the presence of uric acid using NiO nanoparticles decorated on graphene nanosheets modified screen-printed electrodes. Electroanalysis 28:2022–2028
Mohammadi SZ, Beitollahi H, Bani Asadi E (2015) Electrochemical determination of hydrazine using a ZrO2 nanoparticles-modified carbon paste electrode. Environ Monit Assess 187:122–132
Mohammadi SZ, Beitollahi H, Nikpour N, Hosseinzadeh R (2016) Electrochemical sensor for determination of ascorbic acid using a 2-chlorobenzoyl ferrocene/carbon nanotube paste electrode. Anal Bioanal Chem Res 3:187–194
Pingarrón JM, Yanez-Sedeno P, lez-Cortes AG (2008) Gold nanoparticle-based electrochemical biosensors. Electrochim Acta 53:5848–5866
Afkhami A, Gomar F, Madrakian T (2016) CoFe2O4 nanoparticles modified carbon paste electrode for simultaneous detection of oxycodone and codeine in human plasma and urine. Sens Actuators B 233:263–271
Zhang Y, Suryanarayanan V, Nakazawa I, Yoshihara S, Shirakashi T (2004) Electrochemical behavior of Au nanoparticle deposited on as-grown and O-terminated diamond electrodes for oxygen reduction in alkaline solution. Electrochim Acta 49:5235–5240
Beitollahi H, Mohammadi S (2013) Selective voltammetric determination of norepinephrine in the presence of acetaminophen and tryptophan on the surface of a modified carbon nanotube paste electrode. Mater Sci Eng C 33:3214–3219
Penner RM, Martin CR (1987) Preparation and electrochemical characterization of ultramicroelectrode ensembles. Anal Chem 59:2625–2630
Reller H, Kirowa-Eisner E, Gileadi E (1984) Ensembles of microelectrodes: digital simulation by the two-dimensional expanding grid method: cyclic voltammetry, IR effects and applications. J Electroanal Chem 161:247–268
Cassidy J, Ghoroghchian J, Sarfarazi F, Smith JJ, Pons S (1986) Simulation of edge effects in electroanalytical experiments by orthogonal collocation—VI. Cyclic voltammetry at ultramicroelectrode ensembles. Electrochim Acta 31:629–636
Cumba LR, Smith JP, Zuway KY, Sutcliffe OB, do Carmo DR, Banks CE (2016) Forensic electrochemistry: simultaneous voltammetric detection of MDMA and its fatal counterpart “Dr Death” (PMA). Anal Methods 8:142–152
Chan KF, Lim HN, Shams N, Jayabal S, Pandikumar A, Huang NM (2016) Fabrication of graphene/gold-modified screen-printed electrode for detection of carcinoembryonic antigen. Mater Sci Eng C 58:666–674
Chatzipetrou M, Milano F, Giotta L, Chirizzi D, Trotta M, Massaouti M, Guascito MR, Zergioti I (2016) Functionalization of gold screen printed electrodes with bacterial photosynthetic reaction centers by laser printing technology for mediatorless herbicide biosensing. Electrochem Commun 64:46–50
Lezi N, Economou A, Barek J, Prodromidis M (2014) Screen-printed disposable sensors modified with bismuth precursors for rapid voltammetric determination of 3 ecotoxic nitrophenols. Electroanalysis 26:766–775
Mohammadi SZ, Seyedi A (2016) Preconcentration of cadmium and copper ions on magnetic core–shell nanoparticles for determination by flame atomic absorption. Toxicol Environ Chem 98:705–713
Bard AJ, Faulkner LR (2001) Electrochemical methods: fundamentals and applications, 2nd edn. Wiley, New York