Non-enzymatic electrochemical sensing of glucose

Microchimica Acta - Tập 180 Số 3-4 - Trang 161-186 - 2013
Guangfeng Wang1, Xiuping He1, Lingling Wang1, Aixia Gu1, Yan Huang1, Bin Fang1, Baoyou Geng1, Xiaojun Zhang1
1College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, People's Republic of China

Tóm tắt

Từ khóa


Tài liệu tham khảo

WHO (2009) Fact sheet No. 312 in World Health Organization

Wang J (2008) Electrochemical glucose biosensors. Chem Rev 108:814–825

Updike SJ, Hicks GP (1967) The enzyme electrode. Nature 214:986–988

Clark LC, Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 102:29–45

Tsai TW, Heckert G, Neves LF, Tan YQ, Kao DY, Harrison RG, Resasco DE, Schmidtke DW (2009) Adsorption of glucose oxidase onto single-walled carbon nanotubes and its application in layer-by-layer biosensors. Anal Chem 81:7917–7925

Kang XH, Mai ZB, Zou XY, Cai PX, Mo JY (2007) A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes. Anal Biochem 363:143–150

Li X, Zhu QY, Tong SF, Wang W, Song WB (2009) Self-assembled microstructure of carbon nanotubes for enzymeless glucose sensor. Sens Actuators B 136:444–450

Wilson R, Turner APF (1992) Glucose oxidase: an ideal enzyme. Biosens Bioelectron 7:165–185

Park S, Boo H, Chung TD (2006) Electrochemical non-enzymatic glucose sensors. Anal Chim Acta 556:46–57

Toghill KE, Compton RG (2010) Electrochemical non-enzymatic glucose sensors: a perspective and an evaluation. Int J Electrochem Sci 5:1246–1301

Steiner MS, Duerkop A, Wolfbeis OS (2011) Optical methods for sensing glucose. Chem Soc Rev 40:4805–4839

Wang Y, Xu H, Zhang J, Li G (2008) Electrochemical sensors for clinic analysis. Sensors 8:2043–2081

Morikawa M, Kimizuka N, Yoshihara M, Endo T (2002) New colorimetric detection of glucose by means of electron-accepting indicators: ligand substitution of [Fe(acac)3− n(phen)n]n+complexes triggered by electron transfer from glucose oxidase. Chem Eur J 8:5580–5584

Miwa Y, Nishizawa M, Matsue T, Uchida I (1994) A conductometric glucose sensor based on a twin-microband electrode coated with a polyaniline thin film. Bull Chem Soc Jp 67:2864–2866

Mansouri S, Schultz JS (1984) A miniature optical glucose sensor based on affinity binding. Nat Biotech 2:885–890

Pickup JC, Hussain F, Evans ND, Rolinski OJ, Birch DJS (2005) Fluorescence-based glucose sensors. Biosens Bioelectron 20:2555–2565

Liu J, Wang J (2001) A novel improved design for the first-generation glucose biosensor. Food Technol Biotechnol 39:55–58

Tang FQ, Meng XW, Chen D, Ran JG, Zheng CQ (2000) Glucose biosensor enhanced by nanoparticles. Sci China B 43:268–274

Degani Y, Heller A (1989) Electrical communication between redox centers of glucose oxidase and electrodes via electrostatically and covalently bound redox polymers. J Am Chem Soc 111:2357–2358

Accu-Chek (2010) http://www.accu-chek.co.uk/gb

Li J, Lin X (2007) Glucose biosensor based on immobilization of glucose oxidase in poly (o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Biosens Bioelectron 22:2898–2905

Wu B, Zhang G, Shuang S, Choi MMF (2004) Biosensors for determination of glucose with glucose oxidase immobilized on an eggshell membrane. Talanta 64:546–553

Han K, Wu Z, Lee J, Ahn I, Park JW, Min BR, Lee K (2005) Activity of glucose oxidase entrapped in mesoporous gels. Biochem Eng J 22:161–166

Heller A, Feldman B (2010) Electrochemistry in diabetes management. Acc Chem Res 43:963–973

Mao F, Heller A Preparation of transition metal complexes with (pyridyl)imidazole ligands for use in enzyme-based electrochemical sensors. (Main IPC: C07F015-00., Patent Application Country: Application: US; Patent Country: US; Priority Application Country: US, 2003), 2002-143300; 2001-290537, p 23

Heller A, Feldman BJ, Say J, Vreeke MS, Tomasco MF (2003) Small volume in vitro analyte sensor. Main IPC: G01N027-327.; Secondary IPC: C12Q001-00., PCT 98-US2652; 97-795767, p 83

Loeb W (1909) Sugar decomposition III. Electrolysis of dextrose. Biochemische Zeitschrift Biochem Z 17:132–144

Largeaud F, Kokoh KB, Beden B, Lamy C (1995) On the electrochemical reactivity of anomers: electrocatalytic oxidation of α-and β-d-glucose on platinum electrodes in acid and basic media. J Electroanal Chem 397:261–269

Pletcher D (1984) Electrocatalysis: present and future. J Appl Electrochem 14:403–415

Kokkinidis G, Leger JM, Lamy C (1988) Structural effects in electrocatalysis: oxidation of D-glucose on pt (100), (110) and (111) single crystal electrodes and the effect of upd adlayers of Pb, Tl and Bi. J Electroanal Chem Interfacial Electrochem 242:221–242

Hsiao MW, Adzic RR, Yeager EG (1996) Electrochemical oxidation of glucose on single crystal and polycrystalline gold surfaces in phosphate buffer. J Electrochem Soc 143:759–767

Vasil’ev YB, Khazova OA, Nikolaeva NN (1985) Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts: Part II. Effect of the nature of the electrode and the electrooxidation mechanism. J Electroanal Chem Interfacial Electrochem 196:127–144

Bagotskii VS, Vasil’ev YB (1967) Mechanism of electrooxidation of methanol on the platinum electrode. Electrochim Acta 12:1323–1343

Larew LA, Johnson DC (1989) Transient generation of diffusion layer alkalinity for the pulsed amperometric detection of glucose in low capacity buffers having neutral and acidic pH values. J Electroanal Chem Interfacial Electrochem 262:167–182

Burke LD (1994) Premonolayer oxidation and its role in electrocatalysis. Electrochim Acta 39:1841–1848

Ernst S, Heitbaum J, Hamann CH (1979) The electrooxidation of glucose in phosphate buffer solutions: part I. Reactivity and kinetics below 350 mV/RHE. J Electroanal Chem 100:173–183

Shim JH, Jang KY, Lee C, Lee Y (2011) Applications of porous Pt-filled micropore electrode: direct amperometric glucose detection and potentiometric pH sensing. Electroanalysis 23:2063–2069

Joo SY, Park SJ, Chung TD, Kim HC (2007) Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing. Anal Sci 23:277–281

Yuan JH, Wang K, Xia XH (2005) Highly ordered platinum-nanotubule arrays for amperometric glucose sensing. Adv Funct Mater 15:803–809

Guo MQ, Hong HS, Tang XN, Fang HD, Xu XH (2012) Ultrasonic electrodeposition of platinum nanoflowers and their application in nonenzymatic glucose sensors. Electrochim Acta 63:1–8

Huang J (2008) 3-D nanoporous Pt electrode prepared by a 2-D UPD monolayer process. Electroanalysis 20:2229–2234

Chou C, Chen J, Tai C, Sun I, Zen JA (2008) Nonenzymatic glucose sensor using nanoporous platinum electrodes prepared by electrochemical alloying/dealloying in a water-insensitive zinc chloride-1-ethyl-3- methylimidazolium chloride ionic liquid. Electroanalysis 20:771–775

Lee Y, Park D, Park J, Kim Y (2008) Fabrication and optimization of a nanoporous platinum electrode and a non-enzymatic glucose micro-sensor on silicon. Sensors 8:6154–6164

Song Y, Zhang D, Gao W, Xia X (2005) Nonenzymatic glucose detection by using a three-dimensionally ordered, macroporous platinum template. Chem Eur J 11:2177–2182

Lee YJ, Park DJ, Park JY (2008) Fully packaged nonenzymatic glucose microsensors with nanoporous platinum electrodes for anti-fouling. IEEE Sens J 8:1922–1927

Cao Z, Zou Y, Xiang C, Sun L, Xu F (2007) Amperometric glucose biosensor based on ultrafine platinum nanoparticles. Anal Lett 40:2116–2127

Shen QM, Jiang LP, Zhang H, Min QH, Hou WH, Zhu JJ (2008) Three-dimensional dendritic Pt nanostructures: Sonoelectrochemical synthesis and electrochemical applications. J Phys Chem C 112:16385–16392

Luo P, Zhang F, Baldwin RP (1991) Comparison of metallic electrodes for constant-potential amperometric detection of carbohydrates, amino acids and related compounds in flow systems. Anal Chim Acta 244:169–178

Fanguy C, Henry CS (2002) Pulsed amperometric detection of carbohydrates on an electrophoretic microchip. Analyst 127:1021–1023

Park SY, Park SJ, Jeong RA, Boo HK, Park JY, Kim HC, Chung TD (2012) Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt. Biosens Bioelectron 31:284–291

Vasil’ev YB, Khazova OA, Nikolaeva NN (1985) Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts: part I. Adsorption and oxidation on platinum. J Electroanal Chem Interfacial Electrochem 196:105–125

Burke LD (2004) Scope for new applications for gold arising from the electrocatalytic behaviour of its metastable surface states. Gold Bull 37:125–135

Hsiao MW, Adzic RR, Yeager EB (1992) The effects of adsorbed anions on the oxidation of D-glucose on gold single crystal electrodes. Electrochim Acta 37:357–363

Luna AMC, Mele MFL, Arvia AJ (1992) The electro-oxidation of glucose on microcolumnar gold electrodes in different neutral solutions. J Electroanal Chem 323:149–162

Cheng TM, Huang TK, Lin HK, Tung SP, Chen YL, Lee CY, Chiu HT (2010) (110)-Exposed gold nanocoral electrode as low onset potential selective glucose sensor. ACS Appl Mater Interfaces 2:2773–2780

Xu FG, Cui K, Sun YJ, Guo CL, Liu ZL, Zhang Y, Shi Y, Li Z (2010) Facile synthesis of urchin-like gold submicrostructures for nonenzymatic glucose sensing. Talanta 82:1845–1852

Li Y, Song YY, Yang C, Xia XH (2007) Hydrogen bubble dynamic template synthesis of porous gold for nonenzymatic electrochemical detection of glucose. Electrochem Commun 9:981–988

Xia Y, Huang W, Zheng JF, Niu ZJ, Li ZL (2011) Nonenzymatic amperometric response of glucose on a nanoporous gold film electrode fabricated by a rapid and simple electrochemical method. Biosens Bioeletron 26:3555–3561

Cho S, Kang C (2007) Nonenzymatic glucose detection with good selectivity against ascorbic acid on a highly porous gold electrode subjected to amalgamation treatment. Electroanalysis 19:2315–2320

Li JJ, Yuan R, Chai YQ, Che X, Li WJ, Zhong X (2011) Nonenzymatic glucose sensor based on a glassy carbon electrode modified with chains of platinum hollow nanoparticles and porous gold nanoparticles in a chitosan membrane. Microchim Acta 172:163–169

Kurniawan F, Tsakova V, Mirsky VM (2006) Gold nanoparticles in nonenzymatic electrochemical detection of sugars. Electroanalysis 18:1937–1942

Yi Q, Yu W (2009) Electrocatalytic activity of a novel titanium-supported nanoporous gold catalyst for glucose oxidation. Microchim Acta 165:381–386

Cherevko S, Chung C (2009) Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection. Sens Actuators B 142:216–223

Yu J, Lu S, Li J, Zhao F, Zeng B (2007) Characterization of gold nanoparticles electrochemically deposited on amine-functioned mesoporous silica films and electrocatalytic oxidation of glucose. J Solid State Electrochem 11:1211–1219

Feng D, Wang F, Chen Z (2009) Electrochemical glucose sensor based on one-step construction of gold nanoparticle-chitosan composite film. Sens Actuators B 138:539–544

Zhao J, Yu J, Wang F, Hu S (2007) Fabrication of gold nanoparticle-dihexadecyl hydrogen phosphate film on a glassy carbon electrode. Microchim Acta 156:277–282

Bai Y, Yang W, Sun Y, Sun C (2008) Enzyme-free glucose sensor based on a three-dimensional gold film electrode. Sens Actuators B 134:471–476

Zhou Y, Yang S, Qian Q, Xia X (2009) Gold nanoparticles integrated in a nanotube array for electrochemical detection of glucose. Electrochem Commun 11:216–219

Ma Y, Di J, Yan X, Zhao M, Lu Z, Tu Y (2009) Direct electrodeposition of gold nanoparticles on indium tin oxide surface and its application. Biosens Bioelectron 24:1480–1483

Zhao W, Xu JJ, Shi CG, Chen HY (2006) Fabrication, characterization and application of gold nano-structured film. Electrochem Commun 8:773–778

Welch E, Mead DAJ, Johnson DC (1988) A comparison of pulsed amperometric detection and conductivity detection for carbohydrates. Anal Chim Acta 204:323–327

Bindra DS, Wilson GS (1989) Pulsed amperometric detection of glucose in biological fluids at a surface-modified gold electrode. Anal Chem 61:2566–2570

SurareungchaiW DW, Tasakorn P (2001) Quadruple-pulsed amperometric detection for simultaneous flow injection determination of glucose and fructose. Anal Chim Acta 448:215–220

Sattar MA, Conway BE (1969) Eelectrochemistry of the nickel-oxide electrode-VI. Surface oxidation of nickel anodes in alkaline solution. Electrochim Acta 14:705–710

Fleischmann M, Korinek K, Pletcher D (1971) The oxidation of organic compounds at a nickel anode in alkaline solution. J Electroanal Chem Interfacial Electrochem 31:39–49

Bode H, Dehmelt K, Witte J (1966) Zur Kenntnis der Nickelhydroxidelektrode–I. Über das Nickel (II)-hydroxidhydrat. Electrochim Acta 11:1079–1087

Guzman RSS, Vilche JR, Arvia AJ (1978) The potentiodynamic behaviour of iron in alkaline solutions. Electrochim Acta 8:67–70

Wolf JF, Yeh LSR, Damjanovic A (1981) Anodic oxide films at nickel electrodes in alkaline solutions. I. Kinetics of growth of the β-Ni(OH)2 phase. Electrochim Acta 26:409–416

Lu LM, Zhang L, Qu FL, Lu HX, Zhang XB, Wu ZS, Huan SY, Wang QA, Shen GL, Yu RQ (2009) A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: enhancing sensitivity through a nanowire array strategy. Biosens Bioeletron 25:218–223

Zhao CZ, Shao CL, Li MH, Jiao K (2007) Flow-injection analysis of glucose without enzyme based on electrocatalytic oxidation of glucose at a nickel electrode. Talanta 71:1769–1773

Salimi A, Roushani M (2005) Non-enzymatic glucose detection free of ascorbic acid interference using nickel powder and nafion sol–gel dispersed renewable carbon ceramic electrode. Electrochem Commun 7:879–887

Ivandini TA, Sato R, Makide Y, Fujishima A, Einaga Y (2004) Electroanalytical application of modified diamond electrodes. Diamond Relat Mater 13:2003–2008

You T, Niwa O, Chen Z, Hayashi K, Tomita M, Hirono S (2003) An amperometric detector formed of highly dispersed Ni nanoparticles embedded in a graphite-like carbon film electrode for sugar determination. Anal Chem 75:5191–5196

Sue JW, Hung C, Chen W, Zen J (2008) Amperometric determination of sugars at activated barrel plating nickel electrodes. Electroanalysis 20:1647–1654

Goto M, Miyahara H, Ishii D (1990) Constant-potential amperometric detector for carbohydrates at a nickel(III) oxide electrode for micro-scale flow-injection analysis and high-performance liquid chromatography. J Chromatogr A 515:213–220

Stitz A, Buchberger W (1994) Studies on electrochemical reactions at metal-oxide electrodes for combination with high-performance liquid chromatography. Electroanalysis 6:251–258

Uto M, Kodama K, Ishimori K, Kudo Y, Hoshi S, Matsubara M (1994) Nickel-coated hollow-fiber electrode for the electrochemical detection of carbohydrates. Anal Sci 10:835–844

Cataldi RI, Desimoni E, Ricciardi G, Lelj F (1995) Study of the nickel-based chemically modified electrode obtained by electrochemical deposition of an NiII-tetramethyl-dibenzo-tetraaza [14] annulene complex. Redox catalysis of carbohydrates in alkaline solutions. II. Electroanalysis 7:435–441

Casella G, Desimoni E, Salvi AM (1991) Chemically modified electrode for the detection of carbohydrates. Anal Chim Acta 243:61–63

Mu Y, Jia DL, He YY, Miao YQ, Wu HL (2011) Nano nickel oxide modified non-enzymatic glucose sensors with enhanced sensitivity through an electrochemical process strategy at high potential. Biosens Bioelectron 26:2948–2952

Luo ZJ, Yin S, Wang K, Li HM, Wang LG, Xu H, Xia JX (2012) Synthesis of one-dimensional β-Ni(OH)2 nanostructure and their application as nonenzymatic glucose sensors. Mater Chem Phys 132:387–394

Male KB, Hrapovic S, Liu YL, Wang DS, Luong JHT (2004) Electrochemical detection of carbohydrates using copper nanoparticles and carbon nanotubes. Anal Chim Acta 516:35–41

Sun F, Li L, Liu P, Lian YF (2011) Nonenzymatic electrochemical glucose sensor based on novel copper film. Electroanalysis 23:395–401

Wu HX, Cao WM, Li Y, Liu G, Wen Y, Yang HF, Yang SP (2010) In situ growth of copper nanoparticles on multiwalled carbon nanotubes and their application as non-enzymatic glucose sensor materials. Electrochim Acta 55:3734–3740

Yang JA, Zhang WD, Gunasekaran S (2010) An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays. Biosens Bioelectron 26:279–284

Jiang LC, Zhang WD (2010) A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode. Biosens Bioelectron 25:1402–1407

Reitz E, Jia WZ, Gentile M, Wang Y, Lei Y (2008) CuO nanospheres based nonenzymatic glucose sensor. Electroanalysis 20:2482–2486

Wang W, Zhang LL, Tong SF, Li X, Song WB (2009) Effect of sodium borohydride on growth process of controlled flower-like nanostructured Cu2O/CuO films and their hydrophobic property. Biosens Bioelectron 25:708–714

Zhuang ZJ, Su XD, Yuan HY, Sun Q, Xiao D, Choi MMF (2008) An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode. Analyst 133:126–132

Khatib EKM, Hameed RMA (2011) Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination. Biosens Bioelectron 26:3542–3548

Zhang L, Li H, Ni YH, Li J, Liao KM, Zhao GC (2009) Porous cuprous oxide microcubes for non-enzymatic amperometric hydrogen peroxide and glucose sensing. Electrochem Commun 11:812–815

Li CL, Su Y, Zhang SW, Lv XY, Xia HL, Wang YJ (2010) An improved sensitivity nonenzymatic glucose biosensor based on a CuxO modified electrode. Biosens Bioelectron 26:903–907

Lee H, Yoon SW, Kim EJ, Park J (2007) In-situ growth of copper sulfide nanocrystals on multiwalled carbon nanotubes and their application as novel solar cell and amperometric glucose sensor materials. Nano Lett 7:778–784

Fleischmann M, Korinek K, Pletcher D (1972) The kinetics and mechanism of the oxidation of amines and alcohols at oxide-covered nickel, silver, copper, and cobalt electrodes. J Chem Soc Perkin Trans 2:1396–1402

Kano K, Takagi K, Inoue K, Ikeda T, Ueda T (1996) Copper electrodes for stable subpicomole detection of carbohydrates in high-performance liquid chromatography. J Chromatogr A 721:53–57

Kano K, Torimura M, Esaka Y, Goto M, Ueda (1994) T Electrocatalytic oxidation of carbohydrates at copper (II)-modified electrodes and its application to flow-through detection. J Electroanal Chem 372:137–143

Xie Y, Huber CO (1991) Electrocatalysis and amperometric detection using an electrode made of copper oxide and carbon paste. Anal Chem 63:1714–1719

Miller B (1969) Split-ring disk study of the anodic processes at a copper electrode in alkaline solution. J Electrochem Soc 116:1675–1680

Ghanem A, Compton RG, Coles BA, Canals A, Vuorema A, John P, Marken F (2005) Microwave activation of the electro-oxidation of glucose in alkaline media. Phys Chem Chem Phys 7:3552–3559

Yeo IH, Johnson DC (2000) Anodic response of glucose at copper-based alloy electrodes. J Electroanal Chem 484:157–163

Chen DJ, Lu YH, Wang AJ, Feng JJ, Huo TT, Dong WJ (2012) Facile synthesis of ultra-long Cu microdendrites for the electrochemical detection of glucose. J Solid State Electrochem 16:1313–1321

Xu L, Xia JX, Li HM, Li HN, Wang K, Yin S (2011) Ionic liquid assisted solvothermal synthesis of Cu polyhedron-pattern nanostructures and their application as enhanced nanoelectrocatalysts for glucose detection. Eur J Inorg Chem 9:1361–1365

Babu TGS, Ramachandran T, Nair B (2010) Single step modification of copper electrode for the highly sensitive and selective non-enzymatic determination of glucose. Microchim Acta 169:49–55

Huang T, Lin K, Tung S, Cheng T, Chang I, Hsieh Y, Lee C, Chiu H (2009) Glucose sensing by electrochemically grown copper nanobelt electrode. J Electroanal Chem 636:123–127

Watanabe T, Ivandini TA, Makide Y, Fujishima A, Einaga Y (2006) Selective detection method derived from a controlled diffusion process at metal-modified diamond electrodes. Anal Chem 78:7857–7860

Zhao J, Wang F, Yu J, Hu S (2006) Electro-oxidation of glucose at self-assembled monolayers incorporated by copper particles. Talanta 70:449–454

Tong S, Wang W, Li X, Xu Y, Song W (2009) Electrochemical preparation of copper-based/titanate intercalation electrode material. J Phys Chem C 113:6832–6838

Sattayasamitsathit S, Thavarungkul P, Thammakhet C, Limbut W, Numnuam A, Buranachai C, Kanatharana P (2009) Fabrication of nanoporous copper film for electrochemical detection of glucose. Electroanalysis 21:2371–2377

Chen ZL, Hibbert DB (1997) Simultaneous amperometric and potentiometric detection of sugars, polyols and carboxylic acids in flow systems using copper wire electrodes. J Chromatogr A 766:27–33

Zhang YC, Sub L, Manuzzi D, Monteros HVE, Jia WZ, Huo DQ, Hou CJ, Lei Y (2012) Ultrasensitive and selective non-enzymatic glucose detection using copper Nanowires. Biosens Bioelectron 31:426–432

Cao F, Gong J (2012) Nonenzymatic glucose sensor based on CuO microfibers composed of CuO nanoparticles. Anal Chim Acta 723:39–44

Prathap MUA, Kaur B, Srivastava R (2012) Hydrothermal synthesis of CuO micro-/nanostructures and their applications in the oxidative degradation of methylene blue and non-enzymatic sensing of glucose/H2O2. J Colloid Interface Sci 370:144–154

Zhang P, Zhang L, Zhao GC, Feng F (2012) A highly sensitive nonenzymatic glucose sensor based on CuO nanowires. Microchim Acta 176:411–417

Jafarian M, Forouzandeh F, Danaee I, Gobal F, Mahjani MG (2009) Electrocatalytic oxidation of glucose on Ni and NiCu alloy modified glassy carbon electrode. J Solid State Electrochem 13:1171–1179

Lee YJ, Park JY (2011) A coral-like macroporous gold–platinum hybrid 3D electrode for enzyme-free glucose detection. Sens Actuators B 155:134–139

Qiu R, Zhang XL, Qiao R, Li Y, Kim YI, Kang YS (2007) CuNi dendritic material: synthesis, mechanism discussion, and application as glucose sensor. Chem Mater 19:4174–4180

Guo MQ, Wang R, Xu XH (2011) Electrosynthesis of pinecone-shaped Pt–Pb nanostructures based on the application in glucose detection. Mater Sci Eng C 31:1700–1705

Cao F, Guo S, Ma HY, Shan DC, Yang SX, Gong J (2011) Nickel oxide microfibers immobilized onto electrode by electrospinning and calcination for nonenzymatic glucose sensor and effect of calcination temperature on the performance. Biosens Bioeletron 26:2756–2760

Shim JH, Cha A, Lee YM, Lee CM (2011) Nonenzymatic amperometric glucose sensor based on nanoporous gold/ruthenium electrode. Electroanalysis 23:2057–2062

Gutés A, Carraro C, Maboudian (2011) Nonenzymatic glucose sensing based on deposited palladium nanoparticles on epoxy-silver electrodes. Electrochim Acta 56:5855–5859

Chen XL, Pan HB, Liu HF, Du M (2010) Nonenzymatic glucose sensor based on flower-shaped Au@Pd core–shell nanoparticles–ionic liquids composite film modified glassy carbon electrodes. Electrochim Acta 56:636–643

Shi J, Ci PL, Wang F, Peng H, Yang PX, Wang LW, Ge SL, Wang QJ, Chu PK (2011) Nonenzymatic glucose sensor based on over-oxidized polypyrrole modified Pd/Si microchannel plate electrode. Biosens Bioeletron 26:2579–2584

Huang HY, Chen PY (2010) PdNi- and Pd-coated electrodes prepared by electrodeposition from ionic liquid for nonenzymatic electrochemical determination of ethanol and glucose in alkaline media. Talanta 83:379–385

Hui SC, Zhang J, Chen XJ, Xu HH, Ma DF, Liu YL, Tao BR (2011) Study of an amperometric glucose sensor based on Pd–Ni/SiNW electrode. Sens Actuators B 155:592–597

Mahshid SS, Mahshid S, Dolati A, Ghorbani M, Yang LX, Luo SL, Cai QY (2011) Template-based electrodeposition of Pt/Ni nanowires and its catalytic activity towards glucose oxidation. Electrochim Acta 58:551–555

Holt-Hindle P, Nigro S, Asmussen M, Chen A (2008) Amperometric glucose sensor based on platinum–iridium nanomaterials. Electrochem Commun 10:1438–1441

Wang J, Thomas DF, Chen A (2008) Nonenzymatic electrochemical glucose sensor based on nanoporous PtPb networks. Anal Chem 80:997–1004

Bai Y, Sun Y, Sun C (2008) Pt–Pb nanowire array electrode for enzyme-free glucose detection. Biosens Bioelectron 24:579–585

Morita M, Niwa O, Tou S, Watanabe N (1999) Nickel content dependence of electrochemical behavior of carbohydrates on a titanium–nickel alloy electrode and its application to a liquid chromatography detector. J Chromatogr A 837:17–24

Marioli JM, Kuwana T (1993) Electrochemical detection of carbohydrates at nickel-copper and nickel-chromium-iron alloy electrodes. Electroanalysis 5:11–15

Marioli JM, Luo PF, Kuwana T (1993) Nickel-chromium alloy electrode as a carbohydrate detector for liquid chromatography. Anal Chim Acta 282:571–580

Luo PF, Kuwana T (1994) Nickel-titanium alloy electrode as a sensitive and stable LCEC detector for carbohydrates. Anal Chem 66:2775–2882

Mora I, Marioli JM (2001) Honey carbohydrate analysis by HPLC, with electrochemical detection, using a Ni-Cr alloy electrode. J Liq Chromatogr Relat Technol 24:711–720

Noh HB, Lee KS, Chandra P, Won MS, Shim YB (2012) Application of a Cu-Co alloy dendrite on glucose and hydrogen peroxide sensors. Electrochim Acta 61:36–43

Srinivasan C (2007) Graphene - mother of all graphitic materials. Curr Sci 92:1338–1339

Novoselov KS, Geim AK, Morozov SV, Jiang D, Zhang Y, Dubonos SV, Grigorieva IV, Firsov AA (2004) Electric field effect in atomically thin carbon films. Science 306:666–669

Ye JS, Wen Y, Zhang WD, Gan LM, Xu GQ, Sheu FS (2004) Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes. Electrochem Commun 6:66–70

Vlandas A, Kurkina TT, Ahmad A, Kern K, Balasubramanian K (2010) Enzyme-free sugar sensing in microfluidic channels with an affinity-based single-wall carbon nanotube sensor. Anal Chem 82:6090–6097

Wang JX, Sun XW, Cai XP, Lei Y, Song L, Xie SS (2007) Nonenzymatic glucose sensor using freestanding single-wall carbon nanotube films. Electrochem Solid State Lett 10:J58–J60

Yang J, Jiang LC, Zhang WD, Gunasekaran SD (2010) A highly sensitive non-enzymatic glucose sensor based on a simple two-step electrodeposition of cupric oxide (CuO) nanoparticles onto multi-walled carbon nanotube arrays. Talanta 82:5–33

Kang XH, Mai ZB, Zou XY, Cai PX, Mo JY (2007) A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nanotube-modified glassy carbon electrode. Anal Biochem 363:43–150

Jiang F, Wang S, Lin JJ, Jin HL, Zhang LJ, Huang SM, Wang JC (2011) Aligned SWCNT-copper oxide array as a nonenzymatic electrochemical probe for glucose. Electrochem Commun 13:63–365

Yang J, Zhang WD, Gunasekaran SD (2010) An amperometric non-enzymatic glucose sensor by electrodepositing copper nanocubes onto vertically well-aligned multi-walled carbon nanotube arrays. Biosens Bioeletron 6:279–284

Zhu JH, Jiang J, Liu JP, Ding RM, Li YY, Ding H, Feng YM, Wei GM, Huang XT (2011) CNT-network modified Ni nanostructured arrays for high performance non-enzymatic glucose sensors. RSC Advances 1:1020–1025

Zhang XJ, Wang GF, Zhang W, Wei Y, Fang B (2009) Fixure-reduce method for the synthesis of Cu2O/MWCNTs nanocomposites and its application as enzyme-free glucose sensor. Biosens Bioeletron 24:3395–3398

Ryu JG, Kim KH, Kim HS, Hahn HT, Lashmore D (2010) Intense pulsed light induced platinum–gold alloy formation on carbon nanotubes for non-enzymatic glucose detection. Biosens Bioeletron 26:602–607

Liu DY, Luo QM, Zhou FQ (2010) Nonenzymatic glucose sensor based on gold-copper alloy nanoparticles on defect sites of carbon nanotubes by spontaneous reduction. Synth Met 160:745–1748

Li LH, Zhang WD (2008) Preparation of carbon nanotubes supported platinum nanoparticles by an organic colloidal process for nonenzymatic glucose sensing. Microchim Acta 163:305–311

Cui HF, Ye JS, Zhang WD, Li CM, Luongb HT, Sheu FS (2007) Selective and sensitive electrochemical detection of glucose in neutral solution using platinum–lead alloy nanoparticle/carbon nanotube nanocomposites. Anal Chim Acta 594:175–183

Rong LQ, Yang C, Qian QY, Xia XH (2007) Study of the nonenzymatic glucose sensor based on highly dispersed Pt nanoparticles supported on carbon nanotubes. Talanta 72:819–824

Meng L, Jin J, Yang G, Lu T, Zhang H, Cai C (2009) Nonenzymatic electrochemical detection of glucose based on palladium-single-walled carbon nanotube hybrid nanostructures. Anal Chem 81:7271–7280

Myung Y, Jang DM, Cho YJ, Kim HS, Park J, Kim J, Choi Y, Lee CJ (2009) Nonenzymatic amperometric glucose sensing of platinum, copper sulfide, and tin oxide nanoparticle-carbon nanotube hybrid nanostructures. J Phys Chem C 113:1251–1259

Chen J, Zhang WD, Ye JS (2008) Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite. Electrochem Commun 10:1268–1271

Li L, Zhang WD, Ye JS (2008) Electrocatalytic oxidation of glucose at carbon nanotubes supported PtRu nanoparticles and its detection. Electroanalysis 20:2212–2216

Cui HF, Ye JS, Zhang WD, Li CM, Luong JHT, Sheu FS (2007) Selective and sensitive electrochemical detection of glucose in neutral solution using platinum–lead alloy nanoparticle/carbon nanotube nanocomposites. Anal Chim Acta 594:175–183

Xiao F, Zhao F, Mei D, Mo Z, Zeng B (2009) Nonenzymatic glucose sensor based on ultrasonic-electrodeposition of bimetallic PtM (M = Ru, Pd and Au) nanoparticles on carbon nanotubes–ionic liquid composite film. Biosens Bioelectron 24:3481–3486

Buratti S, Brunetti B, Mannino S (2008) Amperometric detection of carbohydrates and thiols by using a glassy carbon electrode coated with Co oxide/multi-wall carbon nanotubes catalytic system. Talanta 76:454–457

Chen XM, Cai ZM, Lin ZJ, Jia T, Liu H, Jiang YQ, Chen X (2009) A novel non-enzymatic ECL sensor for glucose using palladium nanoparticles supported on functional carbon nanotubes. Biosens Bioelectron 24:3475–3480

Lu LM, Zhang XB, Shen GL, Yu RQ (2012) Seed-mediated synthesis of copper nanoparticles on carbon nanotubes and their application in nonenzymatic glucose biosensors. Anal Chim Acta 715:99–104

Geim AK, Novoselov KS (2007) The rise of graphene. Nat Mater 6:183–191

Balandin AA, Ghosh S, Bao W, Calizo I, Teweldebrhan D, Miao F, Lau CN (2008) Superior thermal conductivity of single-layer graphene. Nano Lett 8:902–907

Kim K, Park HJ, Woo BC, Kim KJ, Kim GT, Yun WS (2008) Electric property evolution of structurally defected 5 multilayer graphene. Nano Lett 8:3092–3096

Bai H, Li C, Shi GQ (2011) Functional composite materials based on chemically converted graphene. Adv Mater 23:1089–1115

Gan T, Hu SS (2011) Electrochemical sensors based on graphene materials. Microchim Acta 175:1–19

Luo J, Jiang SS, Zhang HY, Jiang JQ, Liu XY (2012) A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode. Anal Chim Acta 709:47–53

Zhang Y, Xu FG, Sun YJ, Shi Y, Wen ZW, Li Z (2011) Assembly of Ni(OH)2 nanoplates on reduced graphene oxide: a two dimensional nanocomposite for enzyme-free glucose sensing. J Mater Chem 21:16949–16954

Sun JY, Huang KJ, Fan Y, Wu ZW, Li DD (2011) Glassy carbon electrode modified with a film composed of Ni(II), quercetin and graphene for enzyme-less sensing of glucose. Microchim Acta 174:289–294

Kong FY, Li XR, Zhao WW, Xu JJ, Chen HY (2012) Graphene oxide-thionine-Au nanostructure composites: preparation and applications in non-enzymatic glucose sensing. Electrochem Commun 14:59–62

Lu LM, Li HB, Qu FL, Zhang XB, Shen GL, Yu RQ (2011) In situ synthesis of palladium nanoparticle–graphene nanohybrids and their application in nonenzymatic glucose biosensors. Biosens Bioeletron 26:3500–3504

Gao HC, Xiao F, Ching CB, Duan HW (2011) One-step electrochemical synthesis of PtNi nanoparticle-graphene nanocomposites for nonenzymatic amperometric glucose detection. ACS Appl Mater Interfaces 3:3049–3057

Ding RM, Jiang J, Wu F, Gong M, Zhu JH, Huang XT (2011) Cu@C composite nanotube array and its application as an enzyme-free glucose sensor. Nanotechnology 22:1–7

Ni YH, Jin L, Zhang L, Hong JM (2010) Honeycomb-like Ni@C composite nanostructures: synthesis, properties and applications in the detection of glucose and the removal of heavy-metal ions. J Mater Chem 20:6430–6436

Zhong X, Yuan R, Chai YQ (2012) In situ spontaneous reduction synthesis of spherical Pd@Cys-C60 nanoparticles and its application in nonenzymatic glucose biosensors. Chem Commun 48:597–599

Singh BJ, Dempsey E, Dickinson C, Laffir F (2012) Inside/outside Pt nanoparticles decoration of functionalised carbon nanofibers (Pt19.2/f-CNF80.8) for sensitive non-enzymatic electrochemical glucose detection. Analyst 137:1639–1648

Bo XJ, Ndamanisha JC, Bai J, Guo LP (2010) Nonenzymatic amperometric sensor of hydrogen peroxide and glucose based on Pt nanoparticles/ordered mesoporous carbon nanocomposite. Talanta 82:85–91

Su C, Zhang C, Lu GQ, Ma CN (2010) Nonenzymatic electrochemical glucose sensor based on Pt nanoparticles/mesoporous carbon matrix. Electroanalysis 22:1901–1905

Li X, Hu AZ, Jiang J, Ding RM, Liu JP, Huang XT (2011) Preparation of nickel oxide and carbon nanosheet array and its application in glucose sensing. J Solid State Chem 184:2738–2743

Colon LA, Dadoo R, Zare RN (1993) Determination of carbohydrates by capillary zone electrophoresis with amperometric detection at a copper microelectrode. Anal Chem 65:476–481

Luo PF, Prabhu SV, Baldwin RP (1990) Constant potential amperometric detection at a copper-based electrode: electrode formation and operation. Anal Chem 62:752–755

Pang H, Lu QY, Wang JJ, Li YC, Gao F (2010) Glucose-assisted synthesis of copper micropuzzles and their application as nonenzymatic glucose sensors. Chem Commun 46:2010–2012

Batchelor-McAuley C, Wildgoose GG, Compton RG, Shao LD, Green MLH (2008) Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes. Sens Actuators B 132:356–360

Hua L, Chia LS, Goh NK, Tan SN (2000) Amperometric detection of carbohydrates by capillary electrophoresis with a cuprous oxide modified sol–gel carbon composite electrode. Electroanalysis 12:287–291

Ding Y, Liu YX, Parisi J, Zhang LC, Lei Y (2011) A novel NiO–Au hybrid nanobelts based sensor for sensitive and selective glucose detection. Biosens Bioeletron 28:393–398

Wang GF, Wei Y, Zhang W, Zhang XJ, Fang B, Wang L (2010) Enzyme-free amperometric sensing of glucose using Cu-CuO nanowire composites. Microchim Acta 168:87–92

Zhang XJ, Gu AX, Wang GF, Wei Y, Wang W, Wu HQ, Fang B (2010) Fabrication of CuO nanowalls on Cu substrate for a high performance enzyme-free glucose sensor. CrystEngComm 12:1120–1126

Ding Y, Liu YX, Zhang LC, Wang Y, Bellagamba M, Parisi J, Li CM (2011) Sensitive and selective nonenzymatic glucose detection using functional NiO–Pt hybrid nanofibers. Electrochim Acta 58:209–214

Fang B, Gu AX, Wang GF, Wang W, Feng YH, Zhang CH, Zhang XJ (2009) Silver oxide nanowalls grown on cu substrate as an enzymeless glucose sensor. ACS Appl Mater Interfac 1:2829–2834

Wang AJ, Feng JJ, Li ZH, Liao QC, Wang ZZ, Chen JR (2012) Solvothermal synthesis of Cu/Cu2O hollow microspheres for non-enzymatic amperometric glucose sensing. CrystEngComm 14:1289–1295

Wang CX, Yin LW, Zhang LY, Gao R (2010) Ti/TiO2 nanotube array/Ni composite electrodes for nonenzymatic amperometric glucose sensing. J Phys Chem C 114:4408–4413

Casella G, Guascito MR, Cataldi TRI (1999) Electrocatalysis and amperometric detection of alditols and sugars at a gold-nickel composite electrode in anion-exchange chromatography. Anal Chim Acta 398:153–160

Wang J, Zhang WD (2011) Fabrication of CuO nanoplatelets for highly sensitive enzyme-free determination of glucose. Electrochim Acta 56:7510–7516

Illaik A, Taviot-Gueho C, Lavis J, Commereuc S, Verney V, Leroux F (2008) Unusual polystyrene nanocomposite structure using emulsifier-modified layered double hydroxide as nanofiller. Chem Mater 20:4854–4860

Uan JY, Lin JK, Yung YS (2010) Direct growth of oriented Mg–Al layered double hydroxide film on Mg alloy in aqueous HCO3 −/CO3 2− solution. J Mater Chem 20:761–766

Fogg AM, Green VM, Harvey HG, O’Hare D (1999) New separation science using shape-selective ion exchange intercalation chemistry. Adv Mater 11:1466–1469

Shi W, He S, Wei M, Evans DG, Duan X (2010) Optical pH sensor with rapid response based on a fluorescein–intercalated layered double hydroxide. Adv Funct Mater 20:3856–3863

Scavetta E, Stipa S, Tonelli D (2007) Electrodeposition of a nickel-based hydrotalcite on Pt nanoparticles for ethanol and glucose sensing. Electrochem Commun 9:2838–2842

Fogg AM, Dunn JS, Shyu SG, Cary DR, O’Hare D (1998) Selective ion-exchange intercalation of isomeric dicarboxylate anions into the layered double hydroxide [LiAl2(OH)6]Cl H2O. Chem Mater 10:351–355

Zhao Y, Wei M, Lu J, Wang ZL, Duan X (2009) Biotemplated hierarchical nanostructure of layered double hydroxides with improved photocatalysis performance. ACS Nano 3:4009–4016

Yan D, Lu J, Ma J, Wei M, Evans DG, Duan X (2011) Reversibly thermochromic, fluorescent ultrathin films with a supramolecular architecture. Angew Chem Int Ed 50:720–723

Ai HH, Huang XT, Zhu ZH, Liu JP, Chi QB, Li YY (2008) A novel glucose sensor based on monodispersed Ni/Al layered double hydroxide and chitosan. Biosens Bioeletron 24:1048–1052

Li MG, Xu SD, Ni F, Wang YL, Chen SH, Wang L (2009) Fast and sensitive non-enzymatic glucose concentration determination using an electroactive anionic clay-modified electrode. Microchim Acta 166:203–208

Li X, Liu JP, Ji XX, Jiang J, Ding RM, Hu YY, Hu AZ, Huang XT (2010) Ni/Al layered double hydroxide nanosheet film grown directly on Ti substrate and its application for a nonenzymatic glucose sensor. Sens Actuators B 147:241–247

Zhao JW, Kong XG, Shi WY, Shao MF, Han JB, Wei M, Evans DG, Duan X (2011) Self-assembly of layered double hydroxide nanosheets/Au nanoparticles ultrathin films for enzyme-free electrocatalysis of glucose. J Mater Chem 21:13926–13933

Luo J, Zhang HY, Jiang SS, Jiang JQ, Liu XY (2012) Facile one-step electrochemical fabrication of a non-enzymatic glucose-selective glassy carbon electrode modified with copper nanoparticles and graphene. Microchim Acta 177:485–490

Lv W, Jin FM, Guo QG, Yang QH, Kang FY (2012) DNA-dispersed graphene/NiO hybrid materials for highly sensitive non-enzymatic glucose sensor. Electrochim Acta 73:129–135

Zhou XM, Nie HG, Yao Z, Dong YQ, Yang Z, Huang SM (2012) Facile synthesis of nanospindle-like Cu2O/straight multi-walled carbon nanotube hybrid nanostructures and their application in enzyme-free glucose sensing. Sens Actuators B 168:1–7

Zhao Y, Zhao JZ, Ma DC, Li YL, Hao XL, Li LZ, Yu CZ, Zhang L, Lu Y, Wang ZC (2012) Synthesis, growth mechanism of different Cu nanostructures and their application for non-enzymatic glucose sensing. Colloid Surface A 409:105–111

Zhang XJ, Wang LL, Ji R, Yu LT, Wang GF (2012) Nonenzymatic glucose sensor based on Cu–Cu2S nanocomposite electrode. Electrochem Comm 24:53–56

Shi HY, Zhang ZX, Wang Y, Zhu QY, Song WB (2011) Bimetallic nano-structured glucose sensing electrode composed of copper atoms deposited on gold nanoparticles. Microchim Acta 173:85–94

Zhang WD, Chen J, Jiang LC, Yu YX, Zhang JQ (2010) A highly sensitive nonenzymatic glucose sensor based on NiO-modified multi-walled carbon nanotubes. Microchim Acta 168:259–265

Qiao NQ, Zheng JB (2012) Nonenzymatic glucose sensor based on glassy carbon electrode modified with a nanocomposite composed of nickel hydroxide and graphene. Microchim Acta 177:103-109