No differences in infections between patient-specific implants and conventional mini-plates in mandibular bilateral sagittal split osteotomy — Up to 3-year follow-up

Journal of Cranio-Maxillofacial Surgery - Tập 47 - Trang 1181-1184 - 2019
Juho Suojanen1,2, Sanna Järvinen3, Zlatan Hodzic3, Justus Reunanen4, Junnu Leikola1, Patricia Stoor3
1Department of Plastic Surgery, Cleft Palate and Craniofacial Centre, (Head: Hannu Kuokkanen), Helsinki University Central Hospital, Helsinki, Finland
2Päijät-Häme Joint Authority for Health and Wellbeing, Department of Oral and Maxillo-Facial Surgery, (Head: Eeva Kormi), Lahti, Finland
3Department of Oral and Maxillo-Facial Diseases, Clinicum, Faculty of Medicine, (Head: Risto Kontio), University of Helsinki and Helsinki University Central Hospital, Helsinki, Finland
4Cancer and Translational Medicine Research Unit, Biocenter Oulu, (Head: Johanna Myllyharju), University of Oulu, Oulu, Finland

Tài liệu tham khảo

Abdel-Moniem Barakat, 2014, Clinical and radiographic evaluation of a computer-generated guiding device in bilateral sagittal split osteotomies, J Craniomaxillofac Surg, 42, e195, 10.1016/j.jcms.2013.08.007 Arciola, 2015, Biofilm-based implant infections in orthopaedics, Adv Exp Med Biol, 830, 29, 10.1007/978-3-319-11038-7_2 Davis, 2017, Prevalence of surgical site infections following orthognathic surgery: a double-blind, randomized controlled trial on a 3-day versus 1-day postoperative antibiotic regimen, J Oral Maxillofac Surg, 75, 796, 10.1016/j.joms.2016.09.038 Epker, 1977, Modifications in the sagittal osteotomy of the mandible, J Oral Surg, 35, 157 Gander, 2015, Splintless orthognathic surgery: a novel technique using patient-specific implants (PSI), J Craniomaxillofac Surg, 43, 319, 10.1016/j.jcms.2014.12.003 Heufelder, 2017, Clinical accuracy of waferless maxillary positioning using customized surgical guides and patient specific osteosynthesis in bimaxillary orthognathic surgery, J Craniomaxillofac Surg, 45, 1578, 10.1016/j.jcms.2017.06.027 Mazzoni, 2015, Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning, J Oral Maxillofac Surg, 73, 701, 10.1016/j.joms.2014.10.028 Stoor, 2017, Rapid prototyped patient specific guiding implants in critical mandibular reconstruction, J Craniomaxillofac Surg, 45, 63, 10.1016/j.jcms.2016.10.021 Suojanen, 2016, The use of patient specific implants in orthognathic surgery — a series of 32 maxillary osteotomy patients, J Craniomaxillofac Surg, 44, 1913, 10.1016/j.jcms.2016.09.008 Suojanen, 2017, The use of patient-specific implants in orthognathic surgery: a series of 30 mandible sagittal split osteotomy patients, J Craniomaxillofac Surg, 45, 990, 10.1016/j.jcms.2017.02.021 Suojanen, 2018, Comparison between patient specific implants and conventional mini-plates in Le Fort I osteotomy with regard to infections: no differences in up to 3-year follow-up, J Craniomaxillofac Surg, 46, 1814, 10.1016/j.jcms.2018.07.011 Veerachamy, 2014, Bacterial adherence and biofilm formation on medical implants: a review, Proc Inst Mech Eng H, 228, 1083, 10.1177/0954411914556137