Nicht-invasives hämodynamisches Monitoring bei Intensivpatienten

Intensivmedizin und Notfallmedizin - Tập 44 Số 6 - Trang 366-371 - 2007
Hans-Joachim Stemmler1, Oliver Weigert1, Norbert Grüner2, K. Tschöp1, Veronika Lange1, Klaus G. Parhofer2
1Medizinische Klinik und Poliklinik III, Klinikum Großhadern, Klinikum der Ludwig-Maximilians-Universität München, München, Germany
2Medizinische Klinik II, Klinikum Großhadern , Klinikum der Ludwig Maximilians Universität München, München, Germany

Tóm tắt

Từ khóa


Tài liệu tham khảo

Afshari A, Perner A, Bonde J (2006) Circulation monitoring of critically ill patients with the Pulse Contour Cardiac Output system. Ugeskr Laeger, 168:1746–1749

Bajorat J, Hofmockel R, Vagts DA, Janda M, Pohl B, Beck C et al (2006) Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 23:23–30

Bazaral MG, Petre J, Novoa R (1992) Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 77:31–37

Berlauk JF, Abrams JH, Gilmour IJ, O’Connor SR, Knighton DR, Cerra FB (1991) Preoperative optimization of cardiovascular hemodynamics improves outcome in peripheral vascular surgery. A prospective, randomized clinical trial. Ann Surg 214:289–297; discussion 298–299

Bishop MH, Shoemaker WC, Appel PL, Meade P, Ordog GJ, Wasserberger J et al (1995) Prospective, randomized trial of survivor values of cardiac index, oxygen delivery, and oxygen consumption as resuscitation endpoints in severe trauma. J Trauma 38:780–787

Chand R, Mehta Y, Trehan N (2006) Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 20:315–319

Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr,Wagner D et al (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators, Jama 276:889–897

Cottis R, Magee N, Higgins DJ (2003) Haemodynamic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care. Intensive Crit Care Nurs 19:301–307

Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA (2005) Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg 100:748–753 (table of contents)

Knobloch K, Lichtenberg A, Winterhalter M, Rossner D, Pichlmaier M, Phillips R (2005) Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg 80:1479–1483

Latson TW, Whitten CW, O’Flaherty D (1993) Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 79:1233–1243

Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA (2002) Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 15:167–184

Ruperez M, Lopez-Herce J, Garcia C, Sanchez C, Garcia E, Vigil D (2004) Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model. Pediatr Cardiol 25:119–123

Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV (2005) Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth 94:287–291

Wallace DC, Winslow EH (1993) Effects of iced and room temperature injectate on cardiac output measurements in critically ill patients with low and high cardiac outputs. Heart Lung 22:55–63

Wan L, Naka T, Uchino S, Bellomo R (2005) A pilot study of pulse contour cardiac output monitoring in patients with septic shock. Crit Care Resusc 7:165

Zhao X, Mashikian JS, Panzica P, Lerner A, Park KW, Comunale ME (2003) Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post-cardiopulmonary bypass period. J Cardiothorac Vasc Anesth 17:193–198