Near- and mid-infrared laser monitoring of industrial processes, environment and security applications

Optics and Lasers in Engineering - Tập 44 Số 7 - Trang 699-710 - 2006
Ulrike Willer1, Mohammad Saraji1, Alireza Khorsandi1, Peter Geiser1, Wolfgang Schade1
1Institut für Physik und Physikalische Technologien, Technische Universität Clausthal, Leibnizstrasse 4, 38678 Clausthal-Zellerfeld, Germany

Tóm tắt

Từ khóa


Tài liệu tham khảo

Rothman LS, Jacquemart D, Barbe A, Chris Benner D, Birk M, Brown LR, et al. The HITRAN 2004 Molecular Spectroscopic Database. JQSRT, accepted for publication. (preprint: http://cfa-www.harvard.edu/HITRAN/Download/HITRAN04paper.pdf)

Lindsay, 2001, Continous-wave pump-enhanced singly resonant optical parametric oscillator pumped by an extended-cavity diode laser, Appl Phys Lett, 78, 871, 10.1063/1.1345833

Baxter, 2000, Spectroscopic diagnostics of chemical processes: applications of tunable optical parametric oscillators, Appl Phys B, B71, 651, 10.1007/s003400000391

Werle, 2002, Near- and mid-infrared laser-optical sensors for gas analysis, Opt Lasers Eng, 37, 101, 10.1016/S0143-8166(01)00092-6

Faist, 1994, Quantum cascade lasers, Science, 264, 553, 10.1126/science.264.5158.553

Wehe S, Sonnenfroh D, Allen M, Gmachl C, Capasso F. Quantum-cascade laser-based sensor for CO and NO measurements in combustor exhaust flows. In: 37th AIAA/ASME/SAE/ASEE joint propulsion conference and exhibit, 2001, AIAA, 2001–3317.

Kosterev, 2002, Chemical sensors based on quantum cascade lasers, IEEE J QE, 38, 582, 10.1109/JQE.2002.1005408

Chen, 2002, Recent advances in continous-wave laser difference-frequency generation in the mid-infrared: state of the art, applications, and perspectives, Recent Res Dev Appl Phys, 5, 27

Petrov, 1996, Continious-wave tunable 8.7-μm spectroscopic source pumped by fiber-coupled communication lasers, Opt Lett, 21, 1451, 10.1364/OL.21.001451

Lee, 1998, An all-diode-laser-based, dual-cavity AgGaS2 cw difference-frequency source for the 9–11μm range, Appl Phys B, 67, 363, 10.1007/s003400050517

Sumpf, 1997, A cw AgGaS2 difference frequency spectrometer with diode lasers as pump sources, Appl Phys B, 64, 521, 10.1007/s003400050209

Schade, 1996, Compact tunable mid-infrared laser source by difference frequency generation of two diode-lasers, Appl Phys B, 63, 99, 10.1007/BF01112844

Mikulla M. Tapered high-power, high-brightness diode lasers: design and performance. In: Diehl R, editor. High-power diode lasers; Topics Appl Phys 2000; 78:265–88.

Limpert, 2002, Appl Phys B, 75, 477, 10.1007/s00340-002-1018-1

Petrov, 1998, Widely tunable continous-wave mid-infrared laser source based on difference-frequency generation in AgGaS2, Appl Opt, 37, 4925, 10.1364/AO.37.004925

Harrick, 1967

Vogel, 1992

Faber E, Inguaggiato S, Garzon-Valencia G, Seidl D. Mitteilungen Deutsche Geophysikalische Gesellschaft e.V., 1998; Sonderband III: 83–7.

Willer, 2002, Fiber-optic evanescent-field laser sensor for in-situ gas diagnostics, Spectrochim Acta A, 58, 2427, 10.1016/S1386-1425(02)00058-6

Vaselli O, Tassi F, Tedesco D. Private communication 2003.

Wondraczek, 2004, Mid-infrared laser-tomographic imaging of carbon monoxide in laminar flames by difference-frequency generation, Combust Flame, 138, 30, 10.1016/j.combustflame.2004.03.011

Arusi-Parpar, 2001, Photodissociation followed by laser-induced fluorescence at atmospheric pressure and 24°C: a unique scheme for remote detection of explosives, Appl Opt, 40, 6677, 10.1364/AO.40.006677

Kompitsas M, Roubani-Kalantzopoulou F, Bassiotis I, Diamantopoulou A, Giannoudakos A. Laser induced plasma spectroscopy (LIPS) as an efficient method for elemental analysis of environmental samples. In: Proceedings of EARSeL-SIG-workshop LIDAR, Dresden/FRG, 16–17 June, 2000; 130–8.