Near Infrared Method Development for a Continuous Manufacturing Blending Process

Journal of Pharmaceutical Innovation - Tập 9 Số 4 - Trang 291-301 - 2014
Yleana Marie Colon1, Miguel A. Florian2, David Acevedo2, Rafael Méndez2, Rodolfo J. Romañach1
1Department of Chemistry, University of Puerto Rico at Mayagüez, PO Box 9000, Mayagüez Campus, Mayagüez, 00682, Puerto Rico
2Department of Chemical Engineering, University of Puerto Rico at Mayagüez, Mayagüez, Puerto Rico

Tóm tắt

Từ khóa


Tài liệu tham khảo

Bell TA. Challenges in the scale-up of particulate processes—an industrial perspective. Powder Technol. 2005;150(2):60–71.

Leuenberger H. New trends in the production of pharmaceutical granules: the classical batch concept and the problem of scale-up. Eur J Pharm Biopharm. 2001;52(3):279–88.

Mort PR. Scale-up of binder agglomeration processes. Powder Technol. 2005;150(2):86–103.

Rodriguez-Justo O, Morales ÂM. Analysis of process parameters on the characteristics of liposomes prepared by ethanol injection with a view to process scale-up: effect of temperature and batch volume. Chem Eng Res Des. 2011;89(6):785–92.

Florian M, Velázquez C, Méndez R. New continuous tumble mixer characterization. Powder Technol. 2014;256:188–95.

Jamrogiewicz M et al. Determination of API content in a pilot-scale blending by near-infrared spectroscopy as a first step method to process line implementation. Acta Pol Pharm. 2013;70(3):419–29.

Shi Z et al. Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond. J Pharm Biomed Anal. 2008;47(4–5):738–45.

Liew CV, Karande AD, Heng PW. In-line quantification of drug and excipients in cohesive powder blends by near infrared spectroscopy. Int J Pharm. 2010;386(1–2):138–48.

Sekulic SS et al. On-line monitoring of powder blend homogeneity by near-infrared spectroscopy. Anal Chem. 1996;68(3):509–13.

Momose W et al. Process analytical technology applied for end-point detection of pharmaceutical blending by combining two calibration-free methods: simultaneously monitoring specific near-infrared peak intensity and moving block standard deviation. Powder Technol. 2011;210(2):122–31.

Vanarase AU et al. Real-time monitoring of drug concentration in a continuous powder mixing process using NIR spectroscopy. Chem Eng Sci. 2010;65(21):5728–33.

Martínez L et al. Use of near-infrared spectroscopy to quantify drug content on a continuous blending process: influence of mass flow and rotation speed variations. Eur J Pharm Biopharm. 2013;84(3):606–15.

Beach L et al. Near-infrared spectroscopy for the in-line characterization of powder voiding part II: quantification of enhanced flow properties of surface modified active pharmaceutical ingredients. J Pharm Innov. 2010;5(1–2):1–13.

Barnes RJ, Dhanoa MS, Lister SJ. Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra. Appl Spectrosc. 1989;43(5):772–7.

Rinnan Å, Berg Fvd, Engelsen SB. Review of the most common pre-processing techniques for near-infrared spectra. TrAC Trends Anal Chem. 2009;28(10).

Popo M et al. Blend uniformity analysis using stream sampling and near infrared spectroscopy. AAPS PharmSciTech. 2002;3(3):E24.

Andersson M et al. NIR spectroscopy on moving solids using a scanning grating spectrometer—impact on multivariate process analysis. Chemom Intell Lab Syst. 2005;75(1):1–11.

Sulub Y et al. Real-time on-line blend uniformity monitoring using near-infrared reflectance spectrometry: a noninvasive off-line calibration approach. J Pharm Biomed Anal. 2009;49(1):48–54.

Koller DM et al. Continuous quantitative monitoring of powder mixing dynamics by near-infrared spectroscopy. Powder Technol. 2011;205(1–3):87–96.

El-Hagrasy AS et al. Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity. J Pharm Sci. 2001;90(9):1298–307.

Berthiaux H, Marikh K, Gatumel C. Continuous mixing of powder mixtures with pharmaceutical process constraints. Chem Eng Process Process Intensif. 2008;47(12):2315–22.

Bakeev KA. Process analytical technology: spectroscopic tools and implementation strategies for the chemical and pharmaceutical industries. Wiley; 2005.

Petersen L, Esbensen KH. Representative process sampling for reliable data analysis—a tutorial. J Chemom. 2005;19(11–12):625–47.

Engisch WE, Muzzio FJ. Method for characterization of loss-in-weight feeder equipment. Powder Technol. 2012;228:395–403.