NMR imaging techniques and applications: A review

Review of Scientific Instruments - Tập 53 Số 9 - Trang 1319-1337 - 1982
Paul A. Bottomley1
1General Electric Corporate Research & Development Center, P. O. Box 8, Schenectady, New York 12301

Tóm tắt

Over the past ten years, a variety of techniques have been proposed and demonstrated that enable the spatial discrimination and mapping of nuclear-magnetic-resonance (NMR) signals in heterogeneous objects. These NMR imaging techniques are currently finding useful application in clinical medicine and physiological chemistry, where their noninvasive, apparently hazard-free nature, and the sensitivity of the NMR signal to the state of biological tissue, are key advantages. This article reviews the historical development, the conceptual basis, and the applications of the various NMR imaging techniques. Qualitative descriptions and illustrations of each technique and an outline of imaging instrumentation are provided. Proton NMR imaging, in medicine, of pathological states such as cancer, imaging of relaxation time, chemical shift and flow parameters, imaging of nuclei other than hydrogen, and potential hazards are discussed and demonstrated with examples.

Từ khóa


Tài liệu tham khảo

1973, Nature (London), 242, 190, 10.1038/242190a0

1979, Bull. Magn. Reson., 1, 27

1951, C. R. Acad. Sci. (Paris), 232, 1551

1952, Phys. Rev., 85, 694, 10.1103/PhysRev.85.694

1971, Science, 171, 1151, 10.1126/science.171.3976.1151

1954, Phys. Rev., 94, 630, 10.1103/PhysRev.94.630

1965, J. Chem. Phys., 42, 288, 10.1063/1.1695690

1969, Mol. Phys., 17, 355, 10.1080/00268976900101131

1971, J. Appl. Phys., 42, 938, 10.1063/1.1660189

1973, J. Phys. C, 6, L422, 10.1088/0022-3719/6/22/007

1974, J. Phys. C, 7, L457, 10.1088/0022-3719/7/24/006

1975, Phys. Rev. B, 12, 3618, 10.1103/PhysRevB.12.3618

1974, Phys. Lett. A, 48, 87

1976, J. Appl. Phys., 47, 3709, 10.1063/1.323136

1975, Naturwissenschaften, 62, 34, 10.1007/BF00594040

1975, J. Magn. Reson., 18, 69

1979, J. Magn. Reson., 36, 121

1977, Phys. Med. Biol., 22, 971, 10.1088/0031-9155/22/5/016

1977, Nature (London), 270, 722, 10.1038/270722a0

1978, Brit. J. Radiol., 51, 273, 10.1259/0007-1285-51-604-273

1979, Brit. J. Radiol., 52, 36, 10.1259/0007-1285-52-613-36

1979, Cancer Res., 39, 468

1979, Experientia, 35, 1268, 10.1007/BF01963332

1976, J. Phys. C, 9, L409, 10.1088/0022-3719/9/15/004

1976, J. Phys. E, 9, 271, 10.1088/0022-3735/9/4/011

1977, J. Magn. Reson., 27, 101

1977, Brit. J. Radiol., 50, 188, 10.1259/0007-1285-50-591-188

1977, Physiol. Chem. Phys., 9, 97

1978, Naturwissenschaften, 65, 250, 10.1007/BF00368564

1980, J. Comput. Tomography, 4, 419

1980, J. Comput. Assisted Tomography, 4, 429, 10.1097/00004728-198008000-00002

1980, J. Comput. Assisted Tomography, 4, 577, 10.1097/00004728-198010000-00001

1981, J. Comput. Assisted Tomography, 5, 605, 10.1097/00004728-198110000-00001

1981, 5, 613

1981, Am. J. Roentgenol., 137, 895, 10.2214/ajr.137.5.895

1980, J. Phys. E, 13, 947, 10.1088/0022-3735/13/9/013

1980, Phys. Med. Biol., 25, 751, 10.1088/0031-9155/25/4/017

1980, J. Phys. E, 13, 747, 10.1088/0022-3735/13/7/013

1981, J. Comp. Assist. Tomog., 5, 285, 10.1097/00004728-198104000-00032

1980, Radiology, 136, 695, 10.1148/radiology.136.3.7403549

1980, Radiology, 136, 701, 10.1148/radiology.136.3.7403550

1977, J. Magn. Reson., 26, 165

1979, J. Magn. Reson., 33, 183

1980, J. Magn. Reson., 38, 369

1981, J. Magn. Reson., 42, 193

1980, Appl. Phys., 22, 257, 10.1007/BF00899875

1978, Proc. IEEE, 66, 1582, 10.1109/PROC.1978.11161

1975, J. Am. Chem. Soc., 97, 6866, 10.1021/ja00856a046

1980, J. Magn. Reson., 38, 343

1980, Nature (London), 283, 167, 10.1038/283167a0

1980, Nature (London), 287, 736, 10.1038/287736a0

1980, J. Magn. Reson., 40, 209

1981, Science, 211, 177, 10.1126/science.7444460

1980, IEEE Trans. Nucl. Sci., NS-27, 1245

1979, J. Magn. Reson., 33, 83

1979, Rev. Sci. Instrum., 50, 428, 10.1063/1.1135845

1979, J. Appl. Phys., 50, 4491, 10.1063/1.326555

1980, J. Comput. Assisted Tomography, 4, 1

1979, J. Magn. Reson., 35, 261

1978, J. Phys. E, 11, 217, 10.1088/0022-3735/11/3/012

1978, J. Phys. E, 11, 79, 10.1088/0022-3735/11/1/019

1980, IEEE Trans. Nucl. Sci., NS-27, 1239

1975, Radiology, 126, 561

1978, J. Magn. Reson., 30, 129

1981, Brit. J. Radiol., 54, 152, 10.1259/0007-1285-54-638-152

1977, J. Phys. C, 10, L55, 10.1088/0022-3719/10/3/004

1978, J. Magn. Reson., 29, 355

1980, J. Magn. Reson., 41, 112

1979, J. Magn. Reson., 34, 425

1978, Phys. Med. Biol., 23, 630, 10.1088/0031-9155/23/4/006

1982, J. Phys. E, 15, 74, 10.1088/0022-3735/15/1/013

1979, J. Phys. E., 12, 480, 10.1088/0022-3735/12/6/011

1979, Rev. Sci. Instrum., 50, 193, 10.1063/1.1135786

1981, J. Phys. E, 14, 1081, 10.1088/0022-3735/14/9/014

1979, Chem. Biomed. Environ. Instrum., 9, 1

1981, J. Phys. E, 14, 1052, 10.1088/0022-3735/14/9/007

1976, J. Phys. E, 9, 809, 10.1088/0022-3735/9/10/005

1977, J. Phys. E, 10, 714, 10.1088/0022-3735/10/7/014

1978, Phys. Med. Biol., 23, 309, 10.1088/0031-9155/23/2/009

1980, J. Comp. Assist. Tomog., 4, 94, 10.1097/00004728-198002000-00018

1981, Rev. Sci. Instrum., 52, 1342, 10.1063/1.1136769

1981, Rev. Sci. Instrum., 52, 1501, 10.1063/1.1136484

1981, Experientia, 37, 768, 10.1007/BF01967970

1980, Phys. Med. Biol., 25, 748, 10.1088/0031-9155/25/4/016

1978, Physiol. Chem. Phys., 10, 285

1976, Phys. Canada, 32, 33

1978, Phys. Med. Biol., 23, 961, 10.1088/0031-9155/23/5/012

1981, J. Comp. Assist. Tomography, 5, 295

1981, Science, 212, 935, 10.1126/science.7233188

1979, Nature (London), 281, 56, 10.1038/281056a0

1974, Nature (London), 252, 285, 10.1038/252285a0

1977, Contemp. Phys., 18, 351, 10.1080/00107517708231495

1980, Proc. Natl. Acad. Sci. USA, 77, 299, 10.1073/pnas.77.1.299

1981, Journal of Computer Assisted Tomography, 5, 299, 10.1097/00004728-198104000-00044

1981, New Engl. J. Med., 304, 1338, 10.1056/NEJM198105283042206

1977, J. Magn. Reson., 28, 133

1981, Science, 214, 660, 10.1126/science.7292005

1981, Exposure to Nuclear Magnetic Resonance Clinical Imaging, Radiography, XLVII, 258

1981, J. Comp. Assist. Tomography, 5, 800, 10.1097/00004728-198112000-00003

1981, Med. Phys., 8, 510, 10.1118/1.595000

1974, Proc. IEEE, 62, 55, 10.1109/PROC.1974.9385

1980, Proc. Natl. Acad. Sci. USA, 7, 3654

1982, Radiology, 143, 157, 10.1148/radiology.143.1.7038763

1982, Radiology, 143, 168

1982, Radiology, 143, 157, 10.1148/radiology.143.1.7038763