Multidetector Computed Tomography Pulmonary Angiography Pitfalls in the Evaluation of Pulmonary Embolism With Emphasis in Technique

Seminars in Roentgenology - Tập 50 Số 3 - Trang 217-225 - 2015
Diana Palacio1,2, Marcelo F. Benveniste2, Sonia L. Betancourt‐Cuellar2, Gregory W. Gladish2
1Department of Medical Imaging, The University of Arizona College of Medicine, Tucson, Arizona USA
2Department of Radiology, University of Texas MD Anderson Cancer Center, Houston, TX

Tóm tắt

Từ khóa


Tài liệu tham khảo

Burns, 2012, Diagnostic imaging and risk stratification of patients with acute pulmonary embolism, Cardiol Rev, 20, 15, 10.1097/CRD.0b013e31822d2a6a

Fedullo, 2003, Clinical practice. The evaluation of suspected pulmonary embolism, N Engl J Med, 349, 1247, 10.1056/NEJMcp035442

Remy-Jardin, 2007, Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society, Radiology, 245, 315, 10.1148/radiol.2452070397

Thieme, 2009, Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma, Am J Roentgenol, 193, 144, 10.2214/AJR.08.1653

Pontana, 2008, Lung perfusion with dual-energy multidetector-row CT (MDCT): Feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients, Acad Radiol, 15, 1494, 10.1016/j.acra.2008.05.018

Honey, 2009, Dual-energy CT pulmonary angiography: A novel technique for assessing acute and chronic pulmonary thromboembolism, Clin Radiol, 64, 414, 10.1016/j.crad.2008.11.007

Chae, 2010, Dual-energy CT for assessment of the severity of acute pulmonary embolism: Pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio, Am J Roentgenol, 194, 604, 10.2214/AJR.09.2681

Bauer, 2011, Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism–correlation with D-dimer level, right heart strain and clinical outcome, Eur Radiol, 21, 1914, 10.1007/s00330-011-2135-1

Hartmann, 2010, Imaging of acute pulmonary embolism using multi-detector CT angiography: An update on imaging technique and interpretation, Eur J Radiol, 74, 40, 10.1016/j.ejrad.2010.02.007

Safriel, 2002, CT pulmonary angiography in the detection of pulmonary emboli: A meta-analysis of sensitivities and specificities, Clin Imaging, 26, 101, 10.1016/S0899-7071(01)00366-7

Qanadli, 2000, Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients, Radiology, 217, 447, 10.1148/radiology.217.2.r00nv01447

Winer-Muram, 2004, Suspected acute pulmonary embolism: Evaluation with multi-detector row CT versus digital subtraction pulmonary arteriography, Radiology, 233, 806, 10.1148/radiol.2333031744

Stein, 2006, Multidetector computed tomography for acute pulmonary embolism, N Engl J Med, 354, 2317, 10.1056/NEJMoa052367

Coche, 2003, Diagnosis of acute pulmonary embolism in outpatients: Comparison of thin-collimation multi-detector row spiral CT and planar ventilation-perfusion scintigraphy, Radiology, 229, 757, 10.1148/radiol.2293020889

Crawford, 2001, The effect of imaging modality on patient management in the evaluation of pulmonary thromboembolism, J Thorac Imaging, 16, 163, 10.1097/00005382-200107000-00004

Ginsberg, 2004, Comparison of interpretations of CT angiograms in the evaluation of suspected pulmonary embolism by on-call radiology fellows and subsequently by radiology faculty, Am J Roentgenol, 182, 61, 10.2214/ajr.182.1.1820061

Ost, 2001, The negative predictive value of spiral computed tomography for the diagnosis of pulmonary embolism in patients with nondiagnostic ventilation-perfusion scans, Am J Med, 110, 16, 10.1016/S0002-9343(00)00641-0

Remy-Jardin, 2000, Clinical value of thin collimation in the diagnostic workup of pulmonary embolism, Am J Roentgenol, 175, 407, 10.2214/ajr.175.2.1750407

Ruiz, 2003, Prospective comparison of helical CT with angiography in pulmonary embolism: Global and selective vascular territory analysis. Interobserver agreement, Eur Radiol, 13, 823, 10.1007/s00330-002-1588-7

Brunot, 2005, Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism, Eur Radiol, 15, 2057, 10.1007/s00330-005-2844-4

Eyer, 2005, Clinicians׳ response to radiologists׳ reports of isolated subsegmental pulmonary embolism or inconclusive interpretation of pulmonary embolism using MDCT, Am J Roentgenol, 184, 623, 10.2214/ajr.184.2.01840623

Tresoldi, 2008, MDCT of 220 consecutive patients with suspected acute pulmonary embolism: Incidence of pulmonary embolism and of other acute or non-acute thoracic findings, Radiol Med, 113, 373, 10.1007/s11547-008-0262-9

Jones, 2005, The indeterminate CT pulmonary angiogram: Imaging characteristics and patient clinical outcome, Radiology, 237, 329, 10.1148/radiol.2371041520

Schoepf, 2003, Multidetector-row CT imaging of pulmonary embolism, Semin Roentgenol, 38, 106, 10.1016/S0037-198X(03)00020-8

Ghaye, 2007, CT diagnosis of acute pulmonary embolism, 347

Cronin, 2008, The role of multidetector computed tomography angiography for the diagnosis of pulmonary embolism, Semin Nucl Med, 38, 418, 10.1053/j.semnuclmed.2008.07.002

Filipek, 2004, Multidetector pulmonary CT angiography: Advances in the evaluation of pulmonary arterial diseases, Semin Ultrasound CT MR, 25, 83, 10.1016/j.sult.2003.12.003

Wittram, 2004, CT angiography of pulmonary embolism: Diagnostic criteria and causes of misdiagnosis, Radiographics, 24, 1219, 10.1148/rg.245045008

Remy-Jardin, 1998, Spiral CT of pulmonary embolism: Diagnostic approach, interpretive pitfalls and current indications, Eur Radiol, 8, 1376, 10.1007/s003300050557

Aviram, 2004, Pitfalls in the diagnosis of acute pulmonary embolism on spiral computer tomography, Curr Probl Diagn Radiol, 33, 74, 10.1016/j.cpradiol.2003.11.001

Beigelman, 1998, Pitfalls in diagnosis of pulmonary embolism with helical CT angiography, Am J Roentgenol, 171, 579, 10.2214/ajr.171.3.9725276

Gotway, 2000, Helical CT for the evaluation of suspected acute pulmonary embolism: Diagnostic pitfalls, J Comput Assist Tomogr, 24, 267, 10.1097/00004728-200003000-00016

Remy-Jardin, 1997, Spiral CT of pulmonary embolism: Technical considerations and interpretive pitfalls, J Thorac Imaging, 12, 103, 10.1097/00005382-199704000-00009

Kuriakose, 2010, Acute pulmonary embolism, Radiol Clin North Am, 48, 31, 10.1016/j.rcl.2009.10.002

Marten, 2003, ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism, Clin Radiol, 58, 862, 10.1016/S0009-9260(03)00348-9

Hou, 2013, Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embolism in the emergency department: Are we one step closer towards a non-gated triple rule out?, Eur J Radiol, 82, 1793, 10.1016/j.ejrad.2013.05.003

Qin, 2009, CT angiography of pulmonary embolism using a 64 slice multi-detector scanner, Chin Med J (Engl), 122, 2509

Fleischmann, 2003, Use of high concentration contrast media: Principles and rationale-vascular district, Eur J Radiol, 45, S88, 10.1016/S0720-048X(02)00365-0

Rodrigues, 2012, Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose, Clin Radiol, 67, 1053, 10.1016/j.crad.2012.02.010

Douma, 2010, Comparison of 4- and 64-slice CT scanning in the diagnosis of pulmonary embolism, Thromb Haemost, 103, 242, 10.1160/TH09-06-0406

Bae, 2005, Test-bolus versus bolus-tracking techniques for CT angiographic timing, Radiology, 236, 369, 10.1148/radiol.2361050123

Kuriakose, 2010, Acute pulmonary embolism, Thorac Surg Clin, 20, 129, 10.1016/j.thorsurg.2009.12.010

Ramadan, 2010, Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study, Eur Radiol, 20, 2100, 10.1007/s00330-010-1782-y

Behrendt, 2010, Intra-individual comparison of different contrast media concentrations (300mg, 370mg and 400mg iodine) in MDCT, Eur Radiol, 20, 1644, 10.1007/s00330-010-1717-7

Schoellnast, 2005, MDCT angiography of the pulmonary arteries: Influence of iodine flow concentration on vessel attenuation and visualization, Am J Roentgenol, 184, 1935, 10.2214/ajr.184.6.01841935

Patel, 2005, Helical CT for the evaluation of acute pulmonary embolism, Am J Roentgenol, 185, 135, 10.2214/ajr.185.1.01850135

Haage, 2000, Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax, Am J Roentgenol, 174, 1049, 10.2214/ajr.174.4.1741049

Krissak, 2010, Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography, Invest Radiol, 45, 341, 10.1097/RLI.0b013e3181dfda37

Nance, 2012, Optimization of contrast material delivery for dual-energy computed tomography pulmonary angiography in patients with suspected pulmonary embolism, Invest Radiol, 47, 78, 10.1097/RLI.0b013e31821a2142

Hansmann, 2013, Impact of iodine delivery rate with varying flow rates on image quality in dual-energy CT of patients with suspected pulmonary embolism, Acad Radiol, 20, 962, 10.1016/j.acra.2013.02.013

Gosselin, 2004, Contrast dynamics during CT pulmonary angiogram: Analysis of an inspiration associated artifact, J Thorac Imaging, 19, 1, 10.1097/00005382-200401000-00001

Brink, 1997, Depiction of pulmonary emboli with spiral CT: Optimization of display window settings in a porcine model, Radiology, 204, 703, 10.1148/radiology.204.3.9280246

Bae, 2005, CT depiction of pulmonary emboli: Display window settings, Radiology, 236, 677, 10.1148/radiol.2362041558

Mayo, 2013, Pulmonary CT angiography as first-line imaging for PE: Image quality and radiation dose considerations, Am J Roentgenol, 200, 522, 10.2214/AJR.12.9928

Greess, 2000, Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: Evaluation of six anatomical regions, Eur Radiol, 10, 391, 10.1007/s003300050062

Heyer, 2007, Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study, Radiology, 245, 577, 10.1148/radiol.2452061919

Schueller-Weidekamm, 2006, CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings, Radiology, 241, 899, 10.1148/radiol.2413040128

Sigal-Cinqualbre, 2004, Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose, Radiology, 231, 169, 10.1148/radiol.2311030191

Singla Long, 2010, CT features of pulmonary artery sarcoma: Critical aid to a challenging diagnosis, Emerg Radiol, 17, 153, 10.1007/s10140-009-0812-z

Shepard, 1993, Pulmonary intravascular tumor emboli: Dilated and beaded peripheral pulmonary arteries at CT, Radiology, 187, 797, 10.1148/radiology.187.3.8497633

Ozkaya, 2012, In situ thrombosis in pulmonary arterial aneurysms due to Behcet׳s disease and efficacy of immunosuppressive therapy, Multidiscip Respir Med, 7, 33, 10.1186/2049-6958-7-33

Lee, 2012, Pulmonary arterial thrombosis in a patient with an atrial septal defect and eisenmenger syndrome, Korean Circ J, 42, 772, 10.4070/kcj.2012.42.11.772

Fadel, 2007, Dual thrombosis of the pulmonary arterial and venous anastomotic sites after single lung transplantation: Role of transesophageal echocardiography in diagnosis and management, J Am Soc Echocardiogr, 20, 438, 10.1016/j.echo.2006.10.024

Pokora, 1981, Fatal neonatal thrombosis associated with a pulmonary arterial catheter, Crit Care Med, 9, 618, 10.1097/00003246-198108000-00012

Adams, 2013, Adherence to PIOPED II investigators׳ recommendations for computed tomography pulmonary angiography, Am J Med, 126, 36, 10.1016/j.amjmed.2012.05.028