Miniaturisation of high-throughput plasmid DNA library preparation for next-generation sequencing using multifactorial optimisation

Synthetic and Systems Biotechnology - Tập 4 - Trang 57-66 - 2019
Lorna Suckling1, Ciaran McFarlane2, Chelsea Sawyer1, Stephen P. Chambers1, Richard I. Kitney1,3, David W. McClymont1, Paul S. Freemont1,4
1The London DNA Foundry, SynbiCITE, Imperial College London, London, SW7 2AZ, UK
2Department of Life Sciences, Imperial College London, London, SW7 2AZ (UK)
3Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
4Department of Medicine, Imperial College London, London, SW7 2AZ, UK

Tài liệu tham khảo

van Dijk, 2014, Ten years of next-generation sequencing technology, Trends Genet, 30, 418, 10.1016/j.tig.2014.07.001 2017 Shapland, 2015, Low-cost, high-throughput sequencing of DNA assemblies using a highly multiplexed Nextera process, ACS Synth Biol, 4, 860, 10.1021/sb500362n Tan, 2013, A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps, PLoS One, 8 Agrawal, 2016, Utilizing low-volume Aqueous acoustic transfer with the Echo 525 to enable miniaturization of qRT-PCR assay, J Lab Autom, 21, 57, 10.1177/2211068215609315 Chambers, 2016, The Foundry: the DNA synthesis and construction Foundry at imperial college, Biochem Soc Trans, 44, 687, 10.1042/BST20160007 McClymont, 2017, With all due respect to Maholo, lab automation isn't anthropomorphic, Nat Biotechnol, 35, 312, 10.1038/nbt.3795 Engler, 2009, Golden gate shuffling: a one-pot DNA shuffling method based on type IIs restriction enzymes, PLoS One, 4, 10.1371/journal.pone.0005553 Caruccio, 2011, Preparation of next-generation sequencing libraries using NexteraTM technology: simultaneous DNA fragmentation and adaptor tagging by in vitro transposition, Methods Mol Biol, 733, 241, 10.1007/978-1-61779-089-8_17 2018 Anderson, 2000, Design of experiments, 16 Quail, 2012, A tale of three next generation sequencing platforms: comparison of Ion Torrent, Pacific Biosciences and Illumina MiSeq sequencers, BMC Genomics, 13, 341, 10.1186/1471-2164-13-341 Bentley, 2008, Accurate whole human genome sequencing using reversible terminator chemistry, Nature, 456, 53, 10.1038/nature07517 Zerbino, 2008, Velvet: algorithms for de novo short read assembly using de Bruijn graphs, Genome Res, 18, 821, 10.1101/gr.074492.107 Sievers, 2011, Fast, scalable generation of high-quality protein multiple sequence alignments using Clustal Omega, Mol Syst Biol, 7, 539, 10.1038/msb.2011.75 Technical Note, 2018 Ahn, 1996, PicoGreen quantitation of DNA: effective evaluation of samples pre- or post-PCR, Nucleic Acids Res, 24, 2623, 10.1093/nar/24.13.2623 Dean, 2001, Rapid amplification of plasmid and phage DNA using Phi 29 DNA polymerase and multiply-primed rolling circle amplification, Genome Res, 11, 1095, 10.1101/gr.180501 Applied Biological Materials Inc. Full Length Plasmid Sequencing Service ($125.00) | ABM Inc [Internet]. [cited 14 Jan 2019]. Available: https://www.abmgood.com/Full-Length-Plasmid-Sequencing-Service.html. DeAngelis, 1995, Solid-phase reversible immobilization for the isolation of PCR products, Nucleic Acids Res, 23, 4742, 10.1093/nar/23.22.4742 Liu, 2012, Comparison of next-generation sequencing systems, J Biomed Biotechnol., 2012, 251364, 10.1155/2012/251364