Migration resistance of esophageal stents: The role of stent design

Computers in Biology and Medicine - Tập 100 - Trang 43-49 - 2018
Hozhabr Mozafari1, Pengfei Dong1, Shijia Zhao1, Yonghua Bi2, Xinwei Han2, Linxia Gu1,2,3
1Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE, 68588-0656, USA
2Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Henan Province, China
3Nebraska Center for Materials and Nanoscience, Lincoln, NE, 68588-0656, USA

Tài liệu tham khảo

Shaikh, 2015, Engineering stent based delivery system for esophageal cancer using docetaxel, Mol. Pharm., 12, 2305, 10.1021/mp500851u Sjoquist, 2011, Survival after neoadjuvant chemotherapy or chemoradiotherapy for resectable oesophageal carcinoma: an updated meta-analysis, Lancet Oncol., 12, 681, 10.1016/S1470-2045(11)70142-5 Jin, 2018, A PTX/nitinol stent combination with temperature-responsive phase-change 1-hexadecanol for magnetocaloric drug delivery: magnetocaloric drug release and esophagus tissue penetration, Biomaterials, 153, 49, 10.1016/j.biomaterials.2017.10.040 Lazaraki, 2010, Polyflex stents for malignant esophageal strictures: an overview, Ann. Gastroenterol., 23, 17 Park, 2015, Migration of retrievable expandable metallic stents inserted for malignant esophageal strictures: incidence, management, and prognostic factors in 332 patients, Am. J. Roentgenol., 204, 1109, 10.2214/AJR.14.13172 Hindy, 2012, A comprehensive review of esophageal stents, Gastroenterol. Hepatol., 8, 526 Homann, 2008, Delayed complications after placement of self-expanding stents in malignant esophageal obstruction: treatment strategies and survival rate, Dig. Dis. Sci., 53, 334, 10.1007/s10620-007-9862-9 W.C. Wu, R.M. Katon, R.R. Saxon, R.E. Barton, B.T. Uchida, F.S. Keller, J. Rösch, Silicone-covered self-expanding metallic stents for the palliation of malignant esophageal obstruction and esophagorespiratory fistulas: experience in 32 patients and a review of the literature, Gastrointest. Endosc. 40(1) 22–33. Vanbiervliet, 2012, The role of clips in preventing migration of fully covered metallic esophageal stents: a pilot comparative study, Surg. Endosc., 26, 53, 10.1007/s00464-011-1827-6 Franco, 2005 Sharma, 2010, Role of esophageal stents in benign and malignant diseases, Am. J. Gastroenterol., 105, 258, 10.1038/ajg.2009.684 Garbey, 2016, Esophageal stent migration: testing few hypothesis with a simplified mathematical model, Comput. Biol. Med., 79, 259, 10.1016/j.compbiomed.2016.10.024 Kajzer, 2005, Biomechanical analysis of stent–oesophagus system, J. Mater. Process. Technol., 162–163, 196, 10.1016/j.jmatprotec.2005.02.209 Peirlinck, 2018, An in silico biomechanical analysis of the stent–esophagus interaction, Biomechanics Model. Mechanobiol., 17, 111, 10.1007/s10237-017-0948-9 Zhao, 2012, The impact of wire stent fabrication technique on the performance of stent placement, Journal of Medical Devices-Transactions of the Asme, 6 García, 2012, Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent, Journal of the Mechanical Behavior of Biomedical Materials, 10, 166, 10.1016/j.jmbbm.2012.02.006 De Beule, 2008, Realistic finite element-based stent design: the impact of balloon folding, J. Biomech., 41, 383, 10.1016/j.jbiomech.2007.08.014 Lally, 2005, Cardiovascular stent design and vessel stresses: a finite element analysis, J. Biomech., 38, 1574, 10.1016/j.jbiomech.2004.07.022 Yassi, 2009, Modeling of the mechanical function of the human gastroesophageal junction using an anatomically-realistic three-dimensional model, J. Biomech., 42, 1604, 10.1016/j.jbiomech.2009.04.041 Liao, 2004, Two-layered quasi-3D finite element model of the oesophagus, Med. Eng. Phys., 26, 535, 10.1016/j.medengphy.2004.04.009 Yang, 2007, Finite element simulation of food transport through the esophageal body, World J. Gastroenterol.: WJG, 13, 1352, 10.3748/wjg.v13.i9.1352 Zhao, 2012, Performance of self-expanding nitinol stent in a curved artery: impact of stent length and deployment orientation, J. Biomech. Eng., 134, 10.1115/1.4007095 Zhao, 2012, Finite element analysis of the implantation of a self-expanding stent: impact of lesion calcification, J. Med. Dev. Trans. ASME, 6 Rebelo, 2001, Simulation of implantable nitinol stents, 1 Natali, 2009, Biomechanical behaviour of oesophageal tissues: material and structural configuration, experimental data and constitutive analysis, Med. Eng. Phys., 31, 1056, 10.1016/j.medengphy.2009.07.003 Lu, 2001, Regional distribution of axial strain and circumferential residual strain in the layered rabbit oesophagus, J. Biomech., 34, 225, 10.1016/S0021-9290(00)00176-7 Lin, 2017, Friction behavior between endoscopy and esophageal internal surface, Wear, 376–377, 272, 10.1016/j.wear.2016.11.011 Tan, 2001, A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation, Int. J. Cardiol., 78, 51, 10.1016/S0167-5273(00)00472-1 Zhao, 2012, The impact of wire stent fabrication technique on the performance of stent placement, J. Med. Dev. Trans. ASME, 6 Van der Heiden, 2013, The effects of stenting on shear stress: relevance to endothelial injury and repair, Cardiovasc. Res., 99, 269, 10.1093/cvr/cvt090 Saranovic, 2005, Fluoroscopically guided insertion of self-expandable metal esophageal stents for palliative treatment of patients with malignant stenosis of esophagus and cardia: comparison of uncovered and covered stent types, Dis. Esophagus, 18, 230, 10.1111/j.1442-2050.2005.00484.x Song, 1994, Covered, expandable esophageal metallic stent tubes: experiences in 119 patients, Radiology, 193, 689, 10.1148/radiology.193.3.7526414 Verschuur, 2006, A new esophageal stent design (Niti-S stent) for the prevention of migration: a prospective study in 42 patients, Gastrointest. Endosc., 63, 134, 10.1016/j.gie.2005.07.051 R, 1993, A study of the geometrical and mechanical properties of a self-expanding metallic stent—theory and experiment, J. Appl. Biomater., 4, 77, 10.1002/jab.770040111 Stavropoulou, 2012, Biomechanical behavior and histological organization of the three-layered passive esophagus as a function of topography, Proc. IME H J. Eng. Med., 226, 477, 10.1177/0954411912444073 Mughal, 1986, Scintigraphic assessment of oesophageal motility: what does it show and how reliable is it?, Gut, 27, 946, 10.1136/gut.27.8.946 Kou, 2015, A fully resolved active musculo-mechanical model for esophageal transport, J. Comput. Phys., 298, 446, 10.1016/j.jcp.2015.05.049 Kou, 2015, Simulation studies of circular muscle contraction, longitudinal muscle shortening, and their coordination in esophageal transport, Am. J. Physiol. Gastrointest. Liver Physiol., 309, G238, 10.1152/ajpgi.00058.2015 Liu, 2016, A novel biodegradable esophageal stent: results from mechanical and animal experiments, Am. J. Tourism Res., 8, 1108 Gu, 2010, The relation between the arterial stress and restenosis rate after coronary stenting, J. Med. Dev. Trans. ASME, 4, 031005, 10.1115/1.4002238 Zhao, 2013, Experimental investigation of the stent–artery interaction, J. Med. Eng. Technol., 37, 463, 10.3109/03091902.2013.831491 Zhao, 2003, Biomechanical properties of esophagus during systemic treatment with epidermal growth factor in rats, Ann. Biomed. Eng., 31, 700, 10.1114/1.1575758 Fan, 2004, A two-layered mechanical model of the rat esophagus. Experiment and theory, Biomed. Eng. Online, 3, 40, 10.1186/1475-925X-3-40 Yang, 2007, Instability of the two-layered thick-walled esophageal model under the external pressure and circular outer boundary condition, J. Biomech., 40, 481, 10.1016/j.jbiomech.2006.02.020 Sokolis, 2013, Structurally-motivated characterization of the passive pseudo-elastic response of esophagus and its layers, Comput. Biol. Med., 43, 1273, 10.1016/j.compbiomed.2013.06.009 Yang, 2006, 3D Mechanical properties of the layered esophagus: experiment and constitutive model, J. Biomech. Eng., 128, 899, 10.1115/1.2354206