Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty
Tóm tắt
The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA). One hundred 'and one (94.4%) acetabular components did not show significant migration of more than 1 mm. Six (5.6%) implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.
Tài liệu tham khảo
citation_journal_title=Arch Orthop Trauma Surg; citation_title=Press fit fixation of cementless cups: how much stability do we need indeed?; citation_author=A Roth, T Winzer, K Sander, JO Anders, RA Venbrocks; citation_volume=126; citation_issue=2; citation_publication_date=2006; citation_pages=77-81; citation_doi=10.1007/s00402-005-0001-9; citation_id=CR1
citation_journal_title=Clin Orthop Relat Res; citation_title=Hemispheric titanium porous coated acetabular component without screw fixation; citation_author=LD Dorr, Z Wan, J Cohen; citation_volume=35; citation_issue=1; citation_publication_date=1998; citation_pages=158-68; citation_id=CR2
citation_journal_title=J Bone Joint Surg Am; citation_title=Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty; citation_author=AG Valle, A Zoppi, MG Peterson, EA Salvati; citation_volume=86-A; citation_issue=9; citation_publication_date=2004; citation_pages=1998-2004; citation_id=CR3
citation_journal_title=J Arthroplasty; citation_title=Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation; citation_author=CA Engh, RH Hopper, CA Engh; citation_volume=19; citation_issue=7 SupplV; citation_publication_date=2004; citation_pages=54-60; citation_doi=10.1016/j.arth.2004.06.004; citation_id=CR4
citation_journal_title=J Arthroplasty; citation_title=Evaluation of cementless acetabular component migration. An experimental study; citation_author=P Massin, L Schmidt, CA Engh; citation_volume=4; citation_issue=3; citation_publication_date=1989; citation_pages=245-51; citation_doi=10.1016/S0883-5403(89)80020-8; citation_id=CR5
citation_title=Cementless Acetabular Fixation With and Without Screws Analysis of Stability and Migration; citation_inbook_title=J Arthroplasty; citation_publication_date=2009; citation_pages=19; citation_id=CR6; citation_author=R Iorio; citation_author=B Puskas; citation_author=WL Healy; citation_author=JF Tilzey; citation_author=LM Specht; citation_author=MS Thompson
citation_journal_title=J Bone Joint Surg Am; citation_title=Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty; citation_author=RC Wasielewski, LA Cooperstein, MP Kruger, HE Rubash; citation_volume=72; citation_issue=4; citation_publication_date=1990; citation_pages=501-8; citation_id=CR7
citation_journal_title=J Arthroplasty; citation_title=A comparison of cementless acetabular components of the same design: spiked versus supplemental screws; citation_author=MJ Archibeck, D Showalter, TS Kavanaugh, D Camarata, RE White; citation_volume=18; citation_issue=7 Suppl 1; citation_publication_date=2003; citation_pages=122-5; citation_doi=10.1016/S0883-5403(03)00297-3; citation_id=CR8
citation_journal_title=J Arthroplasty; citation_title=A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component; citation_author=LM Kwong, DO O'Connor, RC Sedlacek, RJ Krushell, WJ Maloney, WH Harris; citation_volume=9; citation_issue=2; citation_publication_date=1994; citation_pages=1633-70; citation_doi=10.1016/0883-5403(94)90065-5; citation_id=CR9
citation_journal_title=J Arthroplasty; citation_title=Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips; citation_author=J Thanner, J Karrholm, P Herberts, H Malchau; citation_volume=15; citation_issue=4; citation_publication_date=2000; citation_pages=405-12; citation_doi=10.1054/arth.2000.2963; citation_id=CR10
citation_journal_title=J Bone Joint Surg Am; citation_title=Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up; citation_author=P Udomkiat, LD Dorr, Z Wan; citation_volume=84-A; citation_issue=7; citation_publication_date=2002; citation_pages=1195-200; citation_id=CR11
citation_journal_title=J Arthroplasty; citation_title=The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases; citation_author=TP Schmalzried, SJ Wessinger, GE Hill, WH Harris; citation_volume=9; citation_issue=3; citation_publication_date=1994; citation_pages=235-42; citation_doi=10.1016/0883-5403(94)90077-9; citation_id=CR12
citation_journal_title=J Arthroplasty; citation_title=Cementless porous-coated sockets without holes implanted with pure press-fit technique; citation_author=R Torga Spak, SA Stuchin; citation_volume=20; citation_issue=1; citation_publication_date=2005; citation_pages=4-10; citation_doi=10.1016/j.arth.2004.09.025; citation_id=CR13
citation_journal_title=J Bone Joint Surg; citation_title=Single Price/Case Price Purchasing in orthopaedic surgery: experience at the Lahey Clinic; citation_author=WL Healy, R Iorio, MJ Lemos, DA Patch, BA Pfeifer, PM Smiley, RM Wilk; citation_volume=82; citation_issue=5; citation_publication_date=2000; citation_pages=607-12; citation_id=CR14
citation_journal_title=J Arthroplasty; citation_title=Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty; citation_author=JM Wilkinson, AJ Hamer, RA Elson, I Stockley, R Eastell; citation_volume=17; citation_issue=7; citation_publication_date=2002; citation_pages=910-6; citation_doi=10.1054/arth.2002.34530; citation_id=CR15
citation_journal_title=J Arthroplasty; citation_title=Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty; citation_author=NJ Phillips, I Stockley, JM Wilkinson; citation_volume=17; citation_issue=7; citation_publication_date=2002; citation_pages=917-25; citation_doi=10.1054/arth.2002.34529; citation_id=CR16
citation_journal_title=Acta Orthop Scand; citation_title=EBRA improves the accuracy of radiographic analysis of acetabular cup migration; citation_author=T Ilchmann, U Kesteris, H Wingstrand; citation_volume=69; citation_issue=2; citation_publication_date=1998; citation_pages=119-24; citation_doi=10.3109/17453679809117610; citation_id=CR17
citation_journal_title=J Biomech; citation_title=EBRA: a method to measure migration of acetabular components; citation_author=M Krismer, R Bauer, J Tschupik, P Mayrhofer; citation_volume=28; citation_issue=10; citation_publication_date=1995; citation_pages=1225-336; citation_doi=10.1016/0021-9290(94)00177-6; citation_id=CR18
citation_journal_title=Z Orthop Unfall; citation_title=EBRA migration patterns of the Plasmacup with ceramic or polyethylene inserts: a randomised study; citation_author=U Ochs, T Ilchmann, BG Ochs, J Marx, K Brunnhuber, M Luem, K Weise; citation_volume=145; citation_issue=Suppl 1; citation_publication_date=2007; citation_pages=S20-4; citation_id=CR19
citation_title=Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System; citation_inbook_title=J Arthroplasty; citation_publication_date=2009; citation_pages=17; citation_id=CR20; citation_author=DJ Langton; citation_author=AP Sprowson; citation_author=D Mahadeva; citation_author=S Bhatnagar; citation_author=JP Holland; citation_author=AV Nargol
citation_journal_title=Arch Orthop Trauma Surg; citation_title=Cementless hemiarthroplasty in femoral neck fractures: evaluation of clinical results and measurement of migration by EBRA-FCA; citation_author=T Klestil, R Biedermann, A Kruger, P Gfoller, W Schmoelz, C Rangger, M Krismer, M Blauth; citation_volume=126; citation_issue=6; citation_publication_date=2006; citation_pages=380-6; citation_doi=10.1007/s00402-006-0133-6; citation_id=CR21
citation_journal_title=Acta Orthop; citation_title=Acetabular reconstruction with the Burch-Schneider ring: an EBRA analysis of 40 cup revisions; citation_author=T Ilchmann, JP Gelzer, E Winter, K Weise; citation_volume=77; citation_issue=1; citation_publication_date=2006; citation_pages=79-86; citation_doi=10.1080/17453670610045722; citation_id=CR22
citation_journal_title=Clin Orthop Relat Res; citation_title=Radiological demarcation of cemented sockets in total hip replacement; citation_author=JG DeLee, J Charnley; citation_volume=121; citation_publication_date=1976; citation_pages=20-32; citation_id=CR23
citation_journal_title=J Arthroplasty; citation_title=Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry; citation_author=T Ilchmann, B Mjoberg, H Wingstrand; citation_volume=10; citation_issue=5; citation_publication_date=1995; citation_pages=636-42; citation_doi=10.1016/S0883-5403(05)80208-6; citation_id=CR24
citation_journal_title=Clin Orthop Relat Res; citation_title=The John Charnley Award. Wear is a function of use, not time; citation_author=TP Schmalzried, EF Shepherd, FJ Dorey, WO Jackson, M dela Rosa, F Fa'vae, HA McKellop, CD McClung, J Martell, JR Moreland, HC Amstutz; citation_volume=381; citation_publication_date=2000; citation_pages=36-46; citation_doi=10.1097/00003086-200012000-00005; citation_id=CR25
citation_journal_title=Acta Chir Orthop Traumatol Cech; citation_title=[Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]; citation_author=EW Morscher, KH Widmer, H Bereiter, R Elke, R Schenk; citation_volume=69; citation_issue=1; citation_publication_date=2002; citation_pages=8-15; citation_id=CR26
citation_journal_title=J Arthroplasty; citation_title=Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA; citation_author=SM Rohrl, B Nivbrant, H Strom, KG Nilsson; citation_volume=19; citation_issue=8; citation_publication_date=2004; citation_pages=962-71; citation_id=CR27
citation_journal_title=J Bone Joint Surg Br; citation_title=Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation?; citation_author=CH Won, TC Hearn, M Tile; citation_volume=77; citation_issue=3; citation_publication_date=1995; citation_pages=484-9; citation_id=CR28
citation_journal_title=J Bone Joint Surg Am; citation_title=The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis; citation_author=TP Schmalzried, D Guttmann, M Grecula, HC Amstutz; citation_volume=76; citation_issue=5; citation_publication_date=1994; citation_pages=677-88; citation_id=CR29