Measurements of Restricted Diffusion Using an Oscillating Gradient Spin-Echo Sequence

Journal of Magnetic Resonance - Tập 147 Số 2 - Trang 232-237 - 2000
M. Schachter1, Mark D. Does2, Adam W. Anderson1,2, John C. Gore1,2
1Department of Applied Physics, Yale University, New Haven, Connecticut, 06520
2Department of Diagnostic Radiology, Yale University, New Haven, Connecticut, 06520

Tóm tắt

Từ khóa


Tài liệu tham khảo

Stejskal, 1965, Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient, J. Chem. Phys., 42, 288, 10.1063/1.1695690

Stejskal, 1965, Use of spin echoes in a pulsed magnetic-field gradient to study anisotropic restricted diffusion and flow, J. Chem. Phys., 43, 3597, 10.1063/1.1696526

Mitra, 1992, Effects of microgeometry and surface relaxation on NMR pulsed-field-gradient experiments: Simple pore geometries, Phys. Rev. B, 45, 143, 10.1103/PhysRevB.45.143

Mitra, 1992, Diffusion propagator as a probe of the structure of porous media, Phys. Rev. Lett., 68, 3555, 10.1103/PhysRevLett.68.3555

Latour, 1993, Time-dependent diffusion coefficient of fluids in porous media as a probe to surface-to-volume ratio, J. Magn. Reson., 101, 342, 10.1006/jmra.1993.1056

Mitra, 1993, Short-time behavior of the diffusion coefficient as a geometrical probe of porous media, Phys. Rev. B, 47, 8565, 10.1103/PhysRevB.47.8565

Latour, 1994, Time-dependent diffusion of water in a biological model system, Proc. Natl. Acad. Sci. USA, 91, 1229, 10.1073/pnas.91.4.1229

Moseley, 1990, Early detection of regional cerebral-ischemia in cats—Comparison of diffusion-weighted and T2-weighted MRI and spectroscopy, Magn. Reson. Med., 14, 330, 10.1002/mrm.1910140218

Mintorovitch, 1991, Comparison of diffusion-weighted and T2-weighted MRI for the early detection of cerebral-ischemia and reperfusion in rats, Magn. Reson. Med., 18, 39, 10.1002/mrm.1910180106

Crank, 1967

Haus, 1987, Diffusion in regular and disordered lattices, Phys. Rep., 150, 263, 10.1016/0370-1573(87)90005-6

Coy, 1994, Pulsed gradient spin-echo NMR diffusive diffraction experiments on water surrounding close-packed polymer spheres, J. Colloid Interface Sci., 168, 373, 10.1006/jcis.1994.1432

Gross, 1969, Anwendung der spin-echo-methode der messung der selbstdiffusion, Messtechnik, 77, 171

Stepisnik, 1981, Analysis of NMR self-diffusion measurements by a density matrix calculation, Physica, 104B, 350

Callaghan, 1996, Generalized analysis of motion using magnetic field gradients, Adv. Magn. Opt. Reson., 19, 325, 10.1016/S1057-2732(96)80020-9

Minard, 1995

Hong, 1992, Measuring diffusion in inhomogeneous systems in imaging mode using antisymmetric sensitizing gradients, J. Magn. Reson., 99, 561

Haughey, 1969, Structural properties of packed beds—A review, Can. J. Chem. Eng., 47, 130, 10.1002/cjce.5450470206

Helmer, 1995, The application of porous-media theory to the investigation of time-dependent diffusion in in vivo systems, NMR Biomed., 8, 197, 10.1002/nbm.1940080705

Szafer, 1995, Theoretical model for water diffusion in tissues, Magn. Reson. Med., 33, 697, 10.1002/mrm.1910330516