Measurement properties of the pressure biofeedback unit in the evaluation of transversus abdominis muscle activity: a systematic review
Tài liệu tham khảo
O'Sullivan, 2005, Diagnosis and classification of chronic low back pain disorders: maladaptive movement and motor control impairments as underlying mechanism, Manual Ther, 10, 242, 10.1016/j.math.2005.07.001
Hodges, 1997, Feedforward contraction of transversus abdominis is not influenced by the direction of arm movement, Exp Brain Res, 114, 362, 10.1007/PL00005644
Hides, 2001, Long-term effects of specific stabilizing exercises for first-episode low back pain, Spine, 26, E243, 10.1097/00007632-200106010-00004
Chattanooga Group, 2005
May, 2006, Reliability of procedures used in the physical examination of non-specific low back pain: a systematic review, Aust J Physiother, 52, 91, 10.1016/S0004-9514(06)70044-7
de Vet, 2006, When to use agreement versus reliability measures, J Clin Epidemiol, 59, 1033, 10.1016/j.jclinepi.2005.10.015
Terwee, 2007, Quality criteria were proposed for measurement properties of health status questionnaires, J Clin Epidemiol, 60, 34, 10.1016/j.jclinepi.2006.03.012
Hodges, 1996, Evaluation of the relationship between laboratory and clinical tests of transversus abdominis function, Physiother Res Int, 1, 30, 10.1002/pri.45
Costa, 2004, Confiabilidade do teste palpatório e da unidade de biofeedback pressórico na ativação do músculo transverso abdominal em indivíduos normais, Acta Fisiátrica, 11, 101, 10.11606/issn.2317-0190.v11i3a102487
Costa, 2006, Short report: intra-tester reliability of two clinical tests of transversus abdominis muscle recruitment, Physiother Res Int, 11, 48, 10.1002/pri.39
Storheim, 2002, Intra-tester reproducibility of pressure biofeedback in measurement of transversus abdominis function, Physiother Res Int, 7, 239, 10.1002/pri.263
von Garnier, 2009, Reliability of a test measuring transversus abdominis muscle recruitment with a pressure biofeedback unit, Physiotherapy, 95, 8, 10.1016/j.physio.2008.10.003
Figueiredo, 2005, Estudo da confiabilidade intra e entre-examinadores da unidade de biofeedback pressórico na medida da contração do músculo transverso abdominal, Revista Brasileira de Ciências de Movimento, 13, 93
de Koning, 2008, Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review, Eur Spine J, 17, 905, 10.1007/s00586-008-0656-3
McGinley, 2009, The reliability of three-dimensional kinematic gait measurements: a systematic review, Gait Posture, 29, 360, 10.1016/j.gaitpost.2008.09.003
Koppenhaver, 2009, Rehabilitative ultrasound imaging is a valid measure of trunk muscle size and activation during most isometric sub-maximal contractions: a systematic review, Aust J Physiother, 55, 153, 10.1016/S0004-9514(09)70076-5
Costa, 2009, Reproducibility of rehabilitative ultrasound imaging for the measurement of abdominal muscle activity: a systematic review, Phys Ther, 89, 756, 10.2522/ptj.20080331
Altman, 1991
Chiradejnant, 2003, Objective manual assessment of lumbar posteroanterior stiffness is now possible, J Manipul Physiol Ther, 26, 34, 10.1067/mmt.2003.3
Maher, 1998, An investigation of the reliability and validity of posteroanterior spinal stiffness judgments made using a reference-based protocol, Phys Ther, 78, 829, 10.1093/ptj/78.8.829
Fleiss, 1986
Armstrong, 1981, The intraclass correlation as a measure of interrater reliability of subjective judgments, Nurs Res, 30, 314, 10.1097/00006199-198109000-00014
Costa, 2009, An investigation of the reproducibility of ultrasound measures of abdominal muscle activation in patients with chronic non-specific low back pain, Eur Spine J, 18, 1059, 10.1007/s00586-009-1018-5
de Koning, 2008, Clinimetric evaluation of methods to measure muscle functioning in patients with non-specific neck pain: a systematic review, BMC Musculoskelet Disord, 9, 142, 10.1186/1471-2474-9-142