Measurement of lung volume in mechanically ventilated monkeys with an ultrasonic flow meter and the nitrogen washout method

Intensive Care Medicine - Tập 30 - Trang 127-132 - 2004
Andreas Schibler1, Jürg Hammer2, Ruedi Isler3, Christian Buess4, Christopher J. L. Newth5
1Paediatric Intensive Care, Mater Children’s Hospital South Brisbane, Brisbane, Australia
2Division of Paediatric Intensive Care and Pulmonology, Bruderholzspital , University Children’s Hospital Basel, Basel, Switzerland
3EcoMedics, Dürnten, Switzerland
4Ndd, Zürich, Switzerland
5Anesthesiology Critical Care, Children’s Hospital Los Angeles , University of Southern California, Los Angeles, USA

Tóm tắt

Measurement of functional residual capacity (FRC) during mechanical ventilation is important to standardise respiratory system compliance and adjust the ventilator settings to optimise lung recruitment. In the present study we compared three methods to measure FRC. The bias flow nitrogen washout technique (FRCN2MC), the multiple breath nitrogen washout (FRCMBNW) and the multiple breath sulphur-hexafluoride washout using the molar mass signal of an ultrasonic flow meter (FRCMBSF6) were compared in six adult monkeys after endotracheal intubation and during spontaneous breathing and mechanical ventilation at three different positive end-expiratory pressure (PEEP) levels of 0, 5 and 10 cmH2O. Animal research laboratory. We found good agreement between all three methods and they all accurately measured changes in FRC when PEEP was increased. The coefficients of variance of the three measurement techniques were in the same range (1.3–9.2%). The measurement of the tracer gas concentration with the molar mass signal of the ultrasonic flow meter provides a good and simple alternative to respiratory mass spectrometer for FRC measurements in ventilated subjects.

Tài liệu tham khảo

Sivan Y, Deakers TW, Newth CJL (1991) Effect of positive end-expiratory pressure on respiratory compliance in children with acute respiratory failure. Pediatr Pulmonol 11:103–107 Rimensberger PC, Bryan AC (1999) Measurement of functional residual capacity in the critically ill. Relevance for the assessment of respiratory mechanics during mechanical ventilation. Intensive Care Med 25:540–542 Tepper RS, Merth IT, Newth CJL, Gerhart T (1996) Measurement of functional residual capacity in infants by helium and nitrogen washout techniques. In: Stocks J, Sly PD, Tepper RS, Morgan WJ (eds) Infant respiratory function testing. Wiley, New York, pp 165–189 Sivan Y, Deakers TW, Newth CJL (1990) An automated bedside method for measuring functional residual capacity by N2 washout in mechanically ventilated children. Pediatr Res 28:446–450 Sivan Y, Deakers TW, Newth CJL (1990) Functional residual capacity in ventilated infants and children. Pediatr Res 28:451–454 Schibler A, Henning R (2001) Measurement of functional residual capacity in rabbits and children using an ultrasonic flow meter. Pediatr Res 49:581–588 Schibler A, Henning R (2002) Positive end-expiratory pressure and ventilation inhomogeneity in mechanically ventilated children. Pediatr Crit Care Med 3:124–128 Schüller A, Schaller P. Topfer A, Kirplani H (1994) Measurement of functional residual capacity by sulfur hexafluoride in small-volume lungs during spontaneous breathing and mechanical ventilation. Pediatr Res 35:494–499 Vilstrup CT, Björkulund J, Larsson A, Lachmann B, Werner O (1992) Functional residual capacity and ventilation inhomogeneity in mechanically ventilated small neonates. J Appl Physiol 73 (1):276–283 Brunner JX, Wolff G, Cumming G, Langenstein H (1985) Accurate measurement of N2-volumes during N2 washout requires dynamic adjustment of delay time. J Appl Physiol 59 (3):1008–1012 Wauer J, Leier TU, Henschen M, Wauer RR, Schmalisch G (2003) In vitro validation of an ultrasonic flowmeter in order to measure the functional residual capacity in newborns. Physiol Meas 24(2):355–365 Wrigge H, Sydow M, Zinserling J, Neumann P, Hinz J, Buchardi H (1998) Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patients. Intensive Care Med 24:487–493 Buess C, Burger R, Guggenbühl W (1991) Ultrasonic respiration analysis. IEEE 1597–1598 Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. Statistician 32:307–317 Schibler A, Schneider M, Frey U, Kraemer R (2000) Moment ratio analysis of multiple breath nitrogen washout in infants with lung disease. Eur Respir J 15:1094–1101 Hammer J, Numa A, Newth CJL (1998) Total lung capacity by N2 washout from high and low lung volumes in ventilated infants and children. Am J Respir Crit Care Med 158:526–531