Measurement of Scapular Asymmetry and Assessment of Shoulder Dysfunction Using the Lateral Scapular Slide Test: A Reliability and Validity Study

Physical Therapy - Tập 81 Số 2 - Trang 799-809 - 2001
Corrie Odom1, Andrea B. Taylor2, Christine E Hurd3, Craig R. Denegar4
1CJ Odom, PT, DPT, ATC, is Assistant Clinical Professor, Department of Community and Family Medicine, Division of Physical Therapy, Duke University Medical Center, Durham, NC
2AB Taylor, PhD, is Assistant Professor, Department of Community and Family Medicine, Division of Physical Therapy, Duke University Medical Center, Box 3965, Durham, NC 27710 (USA).
3CE Hurd, PT, DPT, ATC, is Physical Therapist, Youngstown Orthopedics and Sports Therapy, Canfield, Ohio
4CR Denegar, PT, PhD, ATC, is Associate Professor and Director of Undergraduate Athletic Training Education, Departments of Orthopedic Rehabilitation and Kinesiology, Pennsylvania State University, University Park, Pa

Tóm tắt

AbstractBackground and Purpose. The Lateral Scapular Slide Test (LSST) is used to determine scapular position with the arm abducted 0, 45, and 90 degrees in the coronal plane. Assessment of scapular position is based on the derived difference measurement of bilateral scapular distances. The purpose of this study was to assess the reliability of measurements obtained using the LSST and whether they could be used to identify people with and without shoulder impairments. Subjects. Forty-six subjects ranging in age from 18 to 65 years (X̄=30.0, SD=11.1) participated in this study. One group consisted of 20 subjects being treated for shoulder impairments, and one group consisted of 26 subjects without shoulder impairments. Methods. Two measurements in each test position were obtained bilaterally. From the bilateral measurements, we derived the difference measurement. Intraclass correlation coefficients (ICC [1,1]) and the standard error of measurement (SEM) were calculated for intrarater and interrater reliability of the difference in side-to-side measures of scapular distance. Sensitivity and specificity of the LSST for classifying subjects with and without shoulder impairments were also determined. Results. The ICCs for intrarater reliability were .75, .77, and .80 and .52, .66, and .62, respectively, for subjects without and with shoulder impairments in 0, 45, and 90 degrees of abduction. The ICCs for interrater reliability were .67, .43, and .74 and .79, .45, and .57, respectively, for subjects without and with shoulder impairments in 0, 45 and 90 degrees of abduction. The SEMs ranged from 0.57 to 0.86 cm for intrarater reliability and from 0.79 to 1.20 cm for interrater reliability. Using the criterion of greater than 1.0 cm difference, sensitivity and specificity were 35% and 48%, 41% and 54%, and 43% and 56%, respectively, for 0, 45, and 90 degrees of abduction. Sensitivity and specificity based on the criterion of greater than 1.5 cm difference were 28% and 53%, 50% and 58%, and 34% and 52%, respectively, for the 3 scapular positions. Conclusion and Discussion. Our results suggest that measurements of scapular positioning based on the difference in side-to-side scapular distance measures are not reliable. Furthermore, the results suggest that sensitivity and specificity of the LSST measurements are poor and that the LSST should not be used to identify people with and without shoulder dysfunction.

Từ khóa


Tài liệu tham khảo

Kendall, 1977, Posture and Pain

Kendall, 1983, Muscles: Testing and Function

Kisner, 1987, Therapeutic Exercise: Foundations and Techniques

Kibler, 1991, Role of the scapula in the overhead throwing motion, Contemp Orthop, 22, 525

Glousman, 1988, Dynamic electromyographic analysis of the throwing shoulder with glenohumeral instability, J Bone Joint Surg Am, 70, 220, 10.2106/00004623-198870020-00009

Moseley, 1992, EMG analysis of the scapular muscles during a baseball rehabilitation program, Am J Sports Med, 20, 128, 10.1177/036354659202000206

Paine, 1993, The role of the scapula, J Orthop Sports Phys Ther, 18, 386, 10.2519/jospt.1993.18.1.386

Poppen, 1976, Normal and abnormal motion of the shoulder, J Bone Joint Surg Am, 58, 195, 10.2106/00004623-197658020-00006

Donatelli, 1997, Physical Therapy of the Shoulder

Magee, 1997, Orthopedic Physical Assessment

Greenfield, 1995, Posture in patients with shoulder overuse injuries and healthy individuals, J Orthop Sports Phys Ther, 21, 287, 10.2519/jospt.1995.21.5.287

DiVeta, 1990, Relationship between performance of selected scapular muscles and scapular abduction in standing subjects, Phys Ther, 70, 470, 10.1093/ptj/70.8.470

Johnson, 1993, A method for the measurement of three-dimensional scapular movement, Clin Biomech, 8, 269, 10.1016/0268-0033(93)90037-I

Kondo, 1984, Changes in the tilting angle of the scapula following elevation of the arm, Surgery of the Shoulder, 12

Ludewig, 1996, Three-dimensional scapular orientation and muscle activity at selected positions of humeral elevation, J Orthop Sports Phys Ther, 24, 57, 10.2519/jospt.1996.24.2.57

Neiers, 1993, Assessment of scapular position, J Sport Rehab, 2, 20, 10.1123/jsr.2.1.20

Gibson, 1995, A reliability study of measurement techniques to determine static scapular position, J Orthop Sports Phys Ther, 21, 100, 10.2519/jospt.1995.21.2.100

Kibler, 1998, The role of the scapula in athletic shoulder function, Am J Sports Med, 26, 325, 10.1177/03635465980260022801

Kibler, 1989, Abnormalities of scapular position in symptomatic throwing athletes

Griegel-Morris, 1992, Incidence of common postural abnormalities in the cervical shoulder and thoracic regions and their association with pain in two age groups of healthy subjects, Phys Ther, 72, 425, 10.1093/ptj/72.6.425

Johanson, 1997, Differential soft tissue diagnosis, Physical Therapy of the Shoulder, 57

Denegar, 1993, Assessing reliability and precision of measurement: an introduction to intraclass correlation and standard error of measurement, J Sport Rehab, 2, 35, 10.1123/jsr.2.1.35

Shrout, 1979, Intraclass correlations: uses in assessing rater reliability, Psychol Bull, 86, 420, 10.1037/0033-2909.86.2.420

Stratford, 1977, Use of the standard error as a reliability index of interest: an applied example using elbow flexor strength data, Phys Ther, 77, 745, 10.1093/ptj/77.7.745

Safrit, 1989, Criterion-referenced measurement: validity, Measurement Concepts in Physical Education and Exercise Science, 119

Dumholdt, 2000, Physical Therapy Research: Principles and Applications

Portney, 1993, Foundations of Clinical Research: Applications to Practice

SPSS Inc, 1983, SPSSCx User's Guide

Neer, 1983, Impingement lesions, Clin Orthop, 173, 70, 10.1097/00003086-198303000-00010

Freburger, 1999, Measurement of sacroiliac joint dysfunction: a multicenter intertester reliability study, Phys Ther, 79, 1134, 10.1093/ptj/79.12.1134

Potter, 1985, Intertester reliability for selected clinical tests of the sacroiliac joint, Phys Ther, 65, 1671, 10.1093/ptj/65.11.1671

1991, Task Force on Standards for Measurement in Physical Therapy. Standards for Tests and Measurements in Physical Therapy, Phys Ther, 71, 589, 10.1093/ptj/71.8.589

Jobe, 1989, Shoulder pain in the overhead or throwing athletes: the relationship of anterior instability and rotator cuff impingement, Orthop Rev, 18, 963

Haig, 1996, Shoulder Pathophysiology, Rehabilitation, and Treatment

Harryman, 1990, Translation of the humeral head on the glenoid with passive glenohumeral motion, J Bone Joint Surg Am, 72, 1334, 10.2106/00004623-199072090-00009

Culham, 1993, Functional anatomy of the shoulder complex, J Orthop Sports Phys Ther, 18, 342, 10.2519/jospt.1993.18.1.342

Ludewig, 2000, Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement, Phys Ther, 80, 276, 10.1093/ptj/80.3.276

McQuade, 1995, Effects of local muscle fatigue on three-dimensional scapulohumeral rhythm, Clin Biomech, 10, 144, 10.1016/0268-0033(95)93704-W