Managing geometric uncertainty in conformal intensity-modulated radation therapy
Tóm tắt
Từ khóa
Tài liệu tham khảo
Mohan, 1996, Intensity modulation optimization, lateral transport of radiation, and margins, Med Phys, 23, 2011, 10.1118/1.597848
Vos, 1997, Decision criteria and correction strategies on the clinical use of electronic digital portal imagers, 33
Pouliot, 1996, Verification and correction of setup deviations in tangential breast irradiation using EPID: Gain versus workload, Med Phys, 23, 1393, 10.1118/1.597722
Kutcher, 1995, Control, correction, and modeling of setup errors and organ motion, Semin Radiat Oncol, 5, 134, 10.1016/S1053-4296(95)80006-9
Fein, 1996, Intra- and interfractional reproducibility of tangential breast fields: A prospective on-line portal imaging study, Int J Radiat Oncol Biol Phys, 34, 733, 10.1016/0360-3016(95)02037-3
Cionini, 1993, Role of portal imaging in clinical radiotherapy: Florence experience, Radiother Oncol, 29, 221, 10.1016/0167-8140(93)90252-4
Hanley, 1997, Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate, Int J Radiat Oncol Biol Phys, 37, 435, 10.1016/S0360-3016(96)00526-3
Crook, 1995, Prostate motion during standard radiotherapy as assessed by fiducial markers, Radiother Oncol, 37, 35, 10.1016/0167-8140(95)01613-L
van Herk, 1995, Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration, Int J Radiot Oncol Biol Phys, 33, 1311, 10.1016/0360-3016(95)00116-6
Roeske, 1995, Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiotherapy, Int J Radiat Oncol Biol Phys, 33, 1321, 10.1016/0360-3016(95)00225-1
Beard, 1996, Analysis of prostate and seminal vesicle motion: Implication for treatment planning, Int J Radiat Oncol Biol Phys, 34, 451, 10.1016/0360-3016(95)02081-0
Althof, 1996, Variation in prostate position relative to adjacent bony anatomy, Int J Radiat Oncol Biol Phys, 34, 709, 10.1016/0360-3016(95)02162-0
Balter, 1995, Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility, Int J Radiat Oncol Biol Phys, 33, 1281, 10.1016/0360-3016(95)02083-7
Holupka, 1996, Ultrasound image fusion for external beam radiotherapy for prostate cancer, Med Phys, 35, 975
Brahme, 1984, Dosimetric precision requirements in radiation therapy, Acta Radiat Oncol, 23, 379, 10.3109/02841868409136037
Mackie, 1996, Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy, Med Phys, 20, 1709, 10.1118/1.596958
Yu, 1995, Intensity-modulated arc therapy with dynamic multileaf collimation: An alternative to tomotherapy, Phys Med Biol, 40, 1435, 10.1088/0031-9155/40/9/004
Yu, 1998, Effects of intra-fraction organ motion on the delivery of dynamic intensity modulation, Phys Med Biol, 43, 91, 10.1088/0031-9155/43/1/006
Austin-Seymour, 1995, Tumor and target delineation: Current research and future challenges, Int J Radiat Oncol Biol Phys, 33, 1041, 10.1016/0360-3016(95)00215-4
Mackie, 1995, Tomotherapy: Optimized planning and delivery of radiation therapy, International Journal of Imaging Systems and Technology, 6, 43, 10.1002/ima.1850060107
Herring, 1970, The degree of precision required in the radiation dose delivered in cancer radiotherapy, Br J Radiol, 5, 1112
Hendrickson, 1978, The four P's of human error in treatment delivery, Int J Radiat Oncol Biol Phys, 4, 913, 10.1016/0360-3016(78)90056-1
Shalev, 1994, When and how to correct a patient setup, 274
Yan, 1998, The use of adaptive radiation therapy to reduce setup error: A prospective clinical study, Int J Radiat Oncol Biol Phys, 41, 715, 10.1016/S0360-3016(97)00567-1
Marks, 1974, Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma, with extended mantle fields, Cancer, 34, 83, 10.1002/1097-0142(197407)34:1<83::AID-CNCR2820340112>3.0.CO;2-P
Rabinowitz, 1985, Accuracy of radiation field alignment in clinical practice, Int J Radiat Oncol Biol Phys, 11, 1857, 10.1016/0360-3016(85)90046-X
Boyer, 1992, A review of electronic portal imaging devices (EPIDs), Med Phys, 19, 1, 10.1118/1.596878
Shalev, 1997, State of the art in electronic portal imaging, 27
Creutzberg, 1996, A quality control study of the accuracy of patient positioning in irradiation of pelvic fields, Int J Radiat Oncol Biol Phys, 34, 697, 10.1016/0360-3016(95)02034-9
Mubata, 1998, Portal imaging protocol for radical dose-escalated radiotherapy treatment of prostate cancer, Int J Radiat Oncol Biol Phys, 40, 221, 10.1016/S0360-3016(97)00551-8
Kortmann, 1996, Accuracy of field alignment in abdominal radiation therapy, Int J Radiat Oncol Biol Phys, 35, 779, 10.1016/0360-3016(96)00152-6
Michalski, 1996, Prospective clinical evaluation of an electronic portal imaging device, Int J Radiat Oncol Biol Phys, 34, 943, 10.1016/0360-3016(95)02189-2
Vigneault, 1996, Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: A clinical study, Int J Radiat Oncol Biol Phys, 37, 205, 10.1016/S0360-3016(96)00341-0
Jaffray, 1998, Radiographic and tomographic localization of bone and soft-tissue targets on a clinical accelerator, Int J Radiat Oncol Biol Phys
Leibel, 1994, Coping with prostate and seminal vesicle motion in three-dimensional conformal radiation therapy, Int J Radiat Oncol Biol Phys, 28, 327, 10.1016/0360-3016(94)90176-7
Urie, 1991, The role of uncertainty analysis in treatment planning, Int J Radiat Oncol Biol Phys, 21, 91, 10.1016/0360-3016(91)90170-9
Kubo, 1996, Respiration gated radiotherapy treatment: A technical study, Phys Med Biol, 41, 83, 10.1088/0031-9155/41/1/007
Balter, 1996, Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing, Int J Radiat Oncol Biol Phys, 36, 167, 10.1016/S0360-3016(96)00275-1
Hanley, 1996, Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation, Int J Radiat Oncol Biol Phys, 36, 188, 10.1016/S0360-3016(97)85401-6
1993
1978
Mageras, 1996, A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans, Int J Radiat Oncol Biol Phys, 35, 333, 10.1016/0360-3016(96)00008-9
Killoran, 1997, A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy, Int J Radiat Oncol Biol Phys, 37, 213, 10.1016/S0360-3016(96)00477-4
Yan, 1998, The use of adaptive radiation therapy to reduce setup error: A prospective clinical study, Int J Radiat Oncol Biol Phys, 41, 715, 10.1016/S0360-3016(97)00567-1
Blomgren, 1995, Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator, Acta Oncol, 34, 861, 10.3109/02841869509127197
Wong, 1997, The use of active breathing control (ABC) to minimize breathing motion in conformal therapy, 220
Bel, 1996, Target margins for random geometrical treatment uncertainties in conformal radiotherapy, Med Phys, 23, 1537, 10.1118/1.597745
Van den Steene, 1998, Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation, Int J Radiat Oncol Biol Phys, 40, 967, 10.1016/S0360-3016(97)00925-5
Ezz, 1991, Daily monitoring and correction of field placement using a video-based portal imaging system: A pilot study, Int J Radiat Oncol Biol Phys, 22, 159, 10.1016/0360-3016(92)90995-T
Balter, 1997, Incorporation of patient setup measurement and adjustment within a computer controlled radiotherapy system, 182
Balter, 1993, On-line repositioning during treatment of the prostate: A study of potential limits and gains, Int J Radiat Oncol Biol Phys, 27, 137, 10.1016/0360-3016(93)90431-T
Murphy, 1997, An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery, Med Phys, 24, 857, 10.1118/1.598005
Uematsu, 1996, A dual computed tomography linear accelerator unit for stereotactic radiation therapy: a new approach without cranially fixated stereotactic frames, Int J Radiat Oncol Biol Phys, 35, 587, 10.1016/S0360-3016(96)80022-8
Milliken, 1997, Performance of a video-image-subtraction-based patient positioning system, Int J Radiat Oncol Biol Phys, 38, 855, 10.1016/S0360-3016(97)00081-3
Campbell, 1997, The application of positional and dose distribution information in the treatment room, 191
Osaka, 1997, Clinical experience of heavy ion irradiation synchronous with respiration, 176