Malunión femoral en fracturas de diáfisis femoral tratadas con clavo intramedular
Tài liệu tham khảo
Kempf, 1985, Closed locked intramedullary nailing. Its application to comminuted fractures of the femur, J Bone Joint Surg., 67-A, 709, 10.2106/00004623-198567050-00005
Johnson, 1987, Comminuted femoral shaft fractures, Orthop Clinics of North America., 18, 133, 10.1016/S0030-5898(20)32287-2
Alho, 1991, Locked intramedulary nailing of femoral shaft fractures, J Trauma., 31, 49, 10.1097/00005373-199101000-00011
Wiss, 1986, Comminuted and rotationally unstable fractures of the femur treated with an interlocking nail, Clin Orthop., 212, 35, 10.1097/00003086-198611000-00006
Braten, 1995, Femoral shaft fractures treated by intramedullary nailing. A follow-up study focusing on problems related to the method, Injury., 26, 379, 10.1016/0020-1383(95)00054-D
Brumback, 1996, The Rationales of Interlocking Nailing of the Femur,Tibia and Humerus: An Overview, Clin Orthop., 324, 292, 10.1097/00003086-199603000-00036
Bonnevialle, 1998, Troubles torsionnels et inégalités de longueurs aprés enclouage á foyer fermé pour fracture diaphysaire femorale et tibiale, Rev Chir Orthop., 84, 397
Borel, 1993, Enclouage verrouillé des fractures complexes de la diaphyse fémoral de l'adulte. A propos de 68 cas, Rev Chir Orthop., 79, 553
Braten, 1993, Torsional deformity after intramedullary nailing of femoral shaft fractures. Measurement of anteversion angles in 110 patients, J Bone and Joint Surg., 75, 799, 10.1302/0301-620X.75B5.8376444
Jaarsma, 2004, Rotational malalignment after fractures of the femur, J Bone Joint Surg. 2004, 86-B,1100-1104./J Orhop Trauma, 18, 403
Deshmukh, 1998, A technique to obtain correct rotational alignment during closed locked intramedullary nailing of the femur, Injury., 29, 207, 10.1016/S0020-1383(97)00182-4
Krettek, 1998, Intraoperative control of axes, rotation and length in femoral and tibial fractures, Technical note. Injury, 29, SC29, 10.1016/S0020-1383(98)95006-9
Gustilo, 1976, Prevention of infection in the treatment of one thousand and twenty five open fractures of long bones: retrospective and prospective analyses, J Bone and J Surg., 58-A, 453, 10.2106/00004623-197658040-00004
Winquist, 1980, Comminuted fractures of the femoral shaft treated by intramedullary nailing, Orthopedic Clinics of North America., 11, 633, 10.1016/S0030-5898(20)31463-2
Murphy, 1987, Femoral anteversion, J. Bone Joint Surg., 69-A, 1169, 10.2106/00004623-198769080-00010
Ruwe, 1992, Clinical determination of femoral anteversion, J Bone and Joint Surg., 74-A, 820, 10.2106/00004623-199274060-00003
Kuo, 2003, Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference, Investigative Radiology, 38, 221, 10.1097/01.RLI.0000059542.90854.EF
Hooper, 1988, Closed unlocked nailing for comminuted femoral fractures, J Bone and J Surg., 70-B, 619, 10.1302/0301-620X.70B4.3403610
Howe, 1988, Double level fractures of the femur treated with closed intramedullary nailing, Ann Acad Med Singapore, 27, 188
Browner, 1986, Pitfalls, Errors and Complications in the Use of Locking Küntscher Nails, Clin Orthop., 212, 192, 10.1097/00003086-198611000-00021
Krettek, 1996, Unreamed intramedullary nailing of femoral shaft fractures: operative techniques and early clinical experience with the standard locking option, Injury, 4, 233, 10.1016/0020-1383(96)00008-3
Krettek, 1998, Intraoperative control of axes, rotation and length in femoral and tibial fractures, Technical note. Injury, 29, S-C29, 10.1016/S0020-1383(98)95006-9
Antonelli, 1989, Closed intramedullary nailing of diaphyseal fractures of the femur: problems related to anatomical variations of the greater trochanter, Italian J.Orthop.& traumatology, 15, 67
Winquist, 1984, Closed intramedullary nailing of femoral fractures, J Bone and J Surg., 66-A, 529, 10.2106/00004623-198466040-00006
Kempf, 1985, Closed locked intramedullary nailing. Its application to comminuted fractures of the femur, J Bone and J Surg., 67-A, 709, 10.2106/00004623-198567050-00005
Harper, 1987, Curvature of the femur and the proximal entry point for an intramedullary rod, Clin Orthop., 220, 155, 10.1097/00003086-198707000-00021
Georgiadis, 1996, Entry sites for antegrade femoral nailing, Clin Orthop., 330, 281, 10.1097/00003086-199609000-00036
Johnson, 1987, Biomechanical factors affecting fractures stabiliy and femoral bursting in closed intramedullary nailing of femoral shaft fractures, with illustrative case presentations, J Orthop trauma., 1, 1, 10.1097/00005131-198701010-00001
Miller, 1993, The effect of the entry hole for an intramedullary nail on the strngth of the proximal femur, J Bone and J Surg., 75-B, 202, 10.1302/0301-620X.75B2.8444937
Dora, 2001, Entry Point Soft Tissue Damage in Antegrade Femoral Nailing: A Cadaver Study, Journal of Trauma, 15, 488
Kyle, 1994, Fractures of the proximal part of the femur, J Bone and J Surg., 76-A, 924, 10.2106/00004623-199406000-00020
Christie, 1988, Femoral neck fracture during closed medullary nailing: brief report, J. Bone and J Surg., 70-B, 670, 10.1302/0301-620X.70B4.3403626
Kale, 2006, Correct anatomical location of entry point for antegrade femoral nailing, Injury, 37, 990, 10.1016/j.injury.2006.06.003
Strecker, 1997, Lenght and torsion of the lower limb, J. Bone Joint Surg., 79, 1019, 10.1302/0301-620X.79B6.7701
Tornetta, 2000, Antegrade or retrograde reamed femoral nailing, J Bone and J Surg., 82-A, 652, 10.1302/0301-620X.82B5.10038
David, 2002, Femoral intramedulary nailing: Comparison of fracturetable and manual traction, J Bone and J Surg., 84-A, 1514
Jaarsma, 2004, Compensation for rotational malalignment after intramedullary nailing for femoral shaft fractures. An analysis by plantar pressure measurements during gait, Injury, 35, 1270, 10.1016/j.injury.2004.01.016
Krettek, 1997, Recurrent rotational deformity of the femur after static locking of intramedullary nails:case reports, J Bone and J Surgery, 79-B, 4, 10.1302/0301-620X.79B1.6910
Braten, 1992, Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women, Acta orthop Scand, 63, 29, 10.3109/17453679209154844
Reikeras, 1982, A specimen study with special regard to bilateral differences, Acta Orthop Scand, 53, 775, 10.3109/17453678208992291
Sojbjerg, 1990, Locked nailing of comminuted and unstable fractures of the femur, J Bone and J Surg., 72-B, 23, 10.1302/0301-620X.72B1.2298789
Tornetta, 1995, Femoral torsion after interlocked nailing of unstable femoral fractures, J Trauma, 213, 10.1097/00005373-199502000-00011
Yang, 1998, Prevention of malrotation deformity in femoral shaft fracture, J Trauma, 12, 558
Kim, 2001, Predicting the rotationally neutral state of the femur by comparing the shape of the contralateral lesser trochanter, Orthopedics, 24, 1069, 10.3928/0147-7447-20011101-18
Jaarsma, 2005, Avoiding rotational malalignment after fractures of the femur by using the profile of the lesser trochanter: an in vitro study, Arch Orthop Trauma Surg., 125, 184, 10.1007/s00402-004-0790-2
Eckhoff DG, Montgomery WK, Kylcoyne RF, Stamm ER.: Femoral morphometry and anterior knee pain. Clin Orthop. 302:64-68.
Tönnis, 1999, Current concepts review. Acetabular andfemoral anteversion: Relationship with osteoarthritis of the hip, J Boneand J Surg., 81-A, 1747, 10.2106/00004623-199912000-00014