Maintien des résultats de suivi à long terme des holters implantables même en cas d’élargissement des indications : résultats d’une étude française
Tài liệu tham khảo
Salih, 2012, Long-term follow-up after implantable loop recorder in patients with syncope: results of a French general hospital Survey, Ann Cardiol Angeiol (Paris), 61, 331, 10.1016/j.ancard.2012.08.033
Moya, 2001, Mechanism of syncope in patients with isolated syncope and in patients with tilt positive syncope, Circulation, 104, 1261, 10.1161/hc3601.095708
Menozzi, 2002, Mechanism of syncope in patients with heart disease and negative electrophysiologic test, Circulation, 105, 2741, 10.1161/01.CIR.0000018125.31973.87
Brignole, 2001, The mechanism of syncope in patients with bundle branch block and negative electrophysiologic test, Circulation, 104, 2045, 10.1161/hc4201.097837
Krahn, 1995, The etiology of syncope in patients with negative tilt table and electrophysiologic testing, Circulation, 92, 1819, 10.1161/01.CIR.92.7.1819
Krahn, 1999, Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators, Circulation, 99, 406, 10.1161/01.CIR.99.3.406
Nierop, 2000, Heart rhythm during syncope and presyncope, Pacing Clin Electrophysiol, 23, 1532, 10.1046/j.1460-9592.2000.01532.x
Boersma, 2004, Value of implantable loop recorder for the management of patients with unexplained syncope, Europace, 6, 70, 10.1016/j.eupc.2003.09.006
Lombardi, 2005, Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope, Europace, 7, 19, 10.1016/j.eupc.2004.09.003
Pierre, 2008, Implantable loop recorder for recurrent syncope: influence of cardiac conduction abnormalities showing up on resting electrocardiogram and of underlying cardiac disease on follow-up developments, Europace, 10, 477, 10.1093/europace/eun039
Vitale, 2010, Discrepancy between clinical practice and standardized indications for an implantable loop recorder in patients with unexplained syncope, Europace, 12, 1475, 10.1093/europace/euq302
Donateo, 2003, Mechanism of syncope in patients with positive adenosine triphosphate tests, J Am Coll Cardiol, 41, 93, 10.1016/S0735-1097(02)02621-9
Brignole, 2006, Lack of correlation between the responses to tilt testing and adenosine triphosphate test and the mechanism of spontaneous neurally-mediated syncope, Eur Heart J, 27, 2232, 10.1093/eurheartj/ehl164
Deharo, 2006, An implantable loop recorder study of highly symptomatic vasovagal patients: the heart rhythm observed during a spontaneous syncope is identical to the recurrent syncope but not correlated with the head-up tilt test or ATP test, J Am Coll Cardiol, 47, 587, 10.1016/j.jacc.2005.09.043
Moya, 2011, Diagnosis, management, and outcomes of patients with syncope and bundle branch block, Bradycardia detection in Bundle Branch Block (B4) study. Eur Heart J, 32, 1535
Brignole, 2004, Guidelines on management (diagnosis and treatment) of syncope–update 2004, Europace, 6, 467, 10.1016/j.eupc.2004.08.008
Farwell, 2006, The clinical impact of implantable loop recorders in patients with syncope, Eur Heart J, 27, 351, 10.1093/eurheartj/ehi602
Krahn, 2001, Randomized Assessment of Syncope Trial. Conventional diagnostic testing versus a prolonged monitoring strategy, Circulation, 104, 46, 10.1161/01.CIR.104.1.46
Ng, 2004, Arrhythmia detection by patient and autoactivation in implantable loop recorders, J Interv Card Electrophysiol, 10, 147, 10.1023/B:JICE.0000019268.95018.91
Chrysostomakis, 2003, Sensing issues related to the clinical use of implantable loop recorders, Europace, 5, 143, 10.1053/eupc.2002.0301
Krahn, 2004, Insertable loop recorder use for detection of intermittent arrhythmias, Pacing Clin Electrophysiol, 27, 657, 10.1111/j.1540-8159.2004.00502.x