Tóm tắt

We report here an optimisation of the demountable direct injection high efficiency nebuliser (d‐DIHEN) for isotopic measurements with a Neptune (ThermoFisher Scientific, Bremen, Germany) multi‐collector inductively coupled plasma‐mass spectrometer (MC‐ICP‐MS) and describe a method for boron isotopic ratio determination. With direct injection nebulisation 100% of the analyte was introduced into the ICP‐MS plasma and wash times were drastically reduced for elements such as boron and thorium. Compared to the classical stable introduction system (SIS: double Scott/cyclonic spray chamber), sensitivity for boron was 2–5 times higher with d‐DIHEN and wash times up to ten times shorter. Repeatability of 11B/10B sample‐calibrator bracketing measurements reached 0.25‰ (2s) for seawater and coral samples. Method accuracy and reproducibility were tested on mixed reference solutions having δ11B values in the ranges −90 to +40‰ and −2 to +2.5‰, demonstrating our ability to distinguish δ11B values with differences of only 0.25‰. The international seawater reference material NRCC NASS‐5 (National Research Council, Ottawa, Canada), analysed in different sessions over a 10‐month period, yielded an average δ11B value of +39.89 ± 0.25‰, in the upper range of previously published seawater values. A comparison between δ11B determined by d‐DIHEN MC‐ICP‐MS and positive‐TIMS (P‐TIMS) for four modern corals showed an excellent agreement (with bias of less than 0.4‰).

Từ khóa


Tài liệu tham khảo

10.1016/S0009-2541(03)00127-X

10.1016/j.ijms.2004.01.016

10.1039/b815240c

10.1016/S0009-2541(97)00107-1

Catanzaro E.J., 1970, Boric acid, isotopic, and assay standard reference materials, US National Bureau of Standards Special Publication, 260, 17

10.1021/es048387j

10.1016/j.epsl.2005.02.014

10.1016/j.epsl.2008.04.015

10.1016/j.chemgeo.2005.12.006

10.1016/0012-821X(95)00180-K

10.1111/j.1751-908X.2001.tb00788.x

10.1111/j.1751-908X.2003.tb00711.x

10.1016/0016-7037(92)90151-8

10.1029/2004PA001026

10.1016/j.gca.2004.03.002

10.1016/j.chemgeo.2008.12.015

10.1016/0584-8547(85)80173-7

10.1021/ac00133a020

10.1021/ac00266a038

10.1016/S0009-2541(01)00425-9

10.1016/j.epsl.2006.01.056

10.1038/35050058

10.1016/S0009-2541(02)00114-6

10.1021/ac9708553

10.1016/S1387-3806(01)00432-8

10.1016/j.chemgeo.2007.07.015

Minnich M.G., 2001, Spatial aerosol characteristics of a direct injection high efficiency nebulizer via optical patternation, Spectrochimica Acta, 56, 113

10.1016/S0009-2541(10)80004-X

10.1016/j.gca.2004.07.029

10.1126/science.284.5421.1824

10.1016/j.apgeochem.2006.01.005

10.1016/j.apgeochem.2005.11.005

10.1021/ac00043a012

10.1016/S0016-7037(99)00437-8

10.1016/S0003-2670(00)80889-2

10.1016/S0012-821X(97)00134-9

10.1016/0016-7037(87)90183-9

10.1039/b111416f

10.1016/j.sab.2005.12.010

10.1016/0016-7037(91)90455-E

10.1016/j.sab.2006.04.002

10.1016/j.sab.2004.01.004

10.1021/ac00003a007

10.1039/b308403e

10.1016/0168-1176(88)83016-7

10.1016/0016-7037(95)00137-9