Lossless Compression of JPEG2000 Whole Slide Images Is Not Required for Diagnostic Virtual Microscopy

American Journal of Clinical Pathology - Tập 136 Số 6 - Trang 889-895 - 2011
Thomas Kalinski1, Ralf Zwönitzer2, Florian Grabellus3, Sien‐Yi Sheu3, Saadettin Sel4, Harald Hofmann5, Albert Roessner1
11Department of Pathology, Otto-von-Guericke-University, Magdeburg, Germany
22Imassense Deutschland, Berlin, Germany
33Institute of Pathology and Neuropathology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
4Department of Ophthalmology, Martin-Luther University, Halle, Germany.
55Medical Computer Center, Otto-von-Guericke-University, Magdeburg, Germany

Tóm tắt

Abstract The use of lossy compression in medical imaging is controversial, although it is inevitable to reduce large data amounts. In contrast with lossy compression, lossless compression does not impair image quality. In addition to our previous studies, we evaluated virtual 3-dimensional microscopy using JPEG2000 whole slide images of gastric biopsy specimens with or without Helicobacter pylori gastritis using lossless compression (1:1) or lossy compression with different compression levels: 5:1, 10:1, and 20:1. The virtual slides were diagnosed in a blinded manner by 3 pathologists using the updated Sydney classification. The results showed no significant differences in the diagnosis of H pylori between the different levels of compression in virtual microscopy. We assume that lossless compression is not required for diagnostic virtual microscopy. The limits of lossy compression in virtual microscopy without a loss of diagnostic quality still need to be determined. Analogous to the processes in radiology, recommendations for the use of lossy compression in diagnostic virtual microscopy have to be worked out by pathology societies.

Từ khóa


Tài liệu tham khảo

Zwönitzer, 2007, Digital pathology: DICOM-conform draft, testbed, and first results, Comput Methods Programs Biomed, 87, 181, 10.1016/j.cmpb.2007.05.010

Kalinski, 2008, Virtual 3D microscopy using multiplane whole slide images in diagnostic pathology, Am J Clin Pathol, 130, 259, 10.1309/QAM22Y85QCV5JM47

Tuominen, 2009, The application of JPEG2000 in virtual microscopy, J Digit Imaging, 22, 250, 10.1007/s10278-007-9090-z

Kalinski, 2009, Lossy compression in diagnostic virtual 3-dimensional pathology: where is the limit?, Hum Pathol, 40, 998, 10.1016/j.humpath.2008.12.010

Kalinski, 2008, Digital workflow management for quality assessment in pathology, Pathol Res Pract, 204, 17, 10.1016/j.prp.2007.12.001

Kalinski, 2009, Improvements in education in pathology: virtual 3D specimens, Pathol Res Pract, 205, 811, 10.1016/j.prp.2009.04.011

Zwönitzer, 2010, Virtual 3D microscopy in pathology education, Hum Pathol, 41, 457, 10.1016/j.humpath.2009.10.012

Tuominen, 2010, Linking whole-slide microscope images with DICOM by using JPEG2000 interactive protocol, J Digit Imaging, 23, 454, 10.1007/s10278-009-9200-1

Krupinski, 2009, Virtual slide telepathology workstation of the future: lessons learned from teleradiology, Hum Pathol, 40, 1100, 10.1016/j.humpath.2009.04.011

Dixon, 1996, Classification and grading of gastritis: the updated Sydney System: International Workshop on the Histopathology of Gastritis, Houston 1994, Am J Surg Pathol, 20, 1161, 10.1097/00000478-199610000-00001

Siegel, 2004, To compress or not to compress: a compressed debate, J Am Coll Radiol, 1, 981, 10.1016/j.jacr.2004.09.014

Royal College of Radiologists, 2008, The adoption of lossy image data compression for the purpose of clinical interpretation

Loose, 2009, Compression of digital images in radiology: results of a consensus conference [in German], Rofo, 181, 32, 10.1055/s-2008-1027847

Koff, 2009, Pan-Canadian evaluation of irreversible compression ratios (“lossy” compression) for development of national guidelines, J Digit Imaging, 22, 569, 10.1007/s10278-008-9139-7