Longitudinal computational fluid dynamics study of stenosis and aneurysmal degeneration of an aortorenal bypass

Biomechanics and Modeling in Mechanobiology - Tập 19 Số 5 - Trang 1965-1975 - 2020
Zhuxiang Xiong1, Yi Wang2, Zeyang Mou1, Yan Li1, Zhan Li1, Jun Wen3, Ding Yuan4, Tinghui Zheng5
1Department of Applied Mechanics, Sichuan University, Chengdu, 610065, People’s Republic of China
2Department of Computer Science, Sichuan University of Science and Engineering, Zigong, Sichuan, 643000, People’s Republic of China
3School of Civil Engineering and Architecture, Southwest University of Science and Technology, Mianyang, Sichuan, 621010, People’s Republic of China
4Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, 610065, People’s Republic of China
5No. 29 Jiuyanqiao Wangjiang Road, Chengdu, 610064, People’s Republic of China

Tóm tắt

Từ khóa


Tài liệu tham khảo

Alimohammadi M, Agu O, Balabani S, Diaz-Zuccarini V (2014) Development of a patient-specific simulation tool to analyse aortic dissections: assessment of mixed patient-specific flow and pressure boundary conditions. Med Eng Phys 36:275–284

Almanaseer Y, Rosman HS, Kazmouz G, Giraldo AA, Martin J (2005) Severe dilatation of saphenous vein grafts: a late complication of coronary surgery in which the diagnosis is suggested by chest x-ray. Cardiology 104:150–155

Asif A, Lenz O, Merrill D, Cherla G, Cipleu CD, Ellis R, Francois B, Epstein DL, Pennell P (2006) Percutaneous management of perianastomotic stenosis in arteriovenous fistulae: results of a prospective study. Kidney Int 69:1904–1909

Ballarin F, Faggiano E, Manzoni A, Quarteroni A, Rozza G, Ippolito S, Antona C, Scrofani R (2017) Numerical modeling of hemodynamics scenarios of patient-specific coronary artery bypass grafts. Biomech Model Mechanobiol 16:1373–1399

Bath J, Cho JS (2012) Aneurysm of a 32-year-old aortorenal saphenous vein bypass graft. Ann Vasc Surg 26:1128-e7

Beathard GA (1994) The treatment of vascular access graft dysfunction: a nephrologist's view and experience. Adv Ren Replace Ther 1:131–147

Beathard GA, Arnold P, Jackson J, Litchfield T, Physician Operators Forum RMS Life (2003) Aggressive treatment of early fistula failure. Kidney Int 64:1487–1494

Carroll GT, McGloughlin TM, Burke PE, Egan M, Wallis F, Walsh MT (2011) Wall shear stresses remain elevated in mature arteriovenous fistulas: a case study. J Biomech Eng Trans ASME 133:021003

Cheng Z, Tan FPP, Riga CV, Bicknell CD, Hamady MS, Gibbs RGJ, Wood NB, Xu XY (2010) Analysis of flow patterns in a patient-specific aortic dissection model. J Biomech Eng Trans ASME 132:051007

Fan T, Lu Y, Gao Y, Meng J, Tan W, Huo Y, Kassab GS (2016) Hemodynamics of left internal mammary artery bypass graft: effect of anastomotic geometry, coronary artery stenosis, and postoperative time. J Biomech 49:645–652

Figueroa CA, Taylor CA, Chiou AJ, Yeh V, Zarins CK (2009) Magnitude and direction of pulsatile displacement forces acting on thoracic aortic endografts. J Endovasc Ther 16:350–358

Fitts MK, Pike DB, Anderson K, Shiu YT (2014) Hemodynamic shear stress and endothelial dysfunction in hemodialysis access. Open Urol Nephrol J 7:33–44

Friedman MH, Bargeron CB, Duncan DD, Hutchins GM, Mark FF (1992) Effects of arterial compliance and non-Newtonian rheology on correlations between intimal thickness and wall shear. J Biomech Eng 114:317–320

Hansen KJ, Deitch JS, Oskin TC, Ligush J, Craven TE, Dean RH (1998) Renal artery repair: consequence of operative failures. Ann Surg 227:678–690

Hathcock JJ (2006) Flow effects on coagulation and thrombosis. Arterioscler Thromb Vasc Biol 26:1729–1737

Huang B, Yuan D, Zhao J, Ma Y (2012) Hybrid treatment of a thoracoabdominal aortic aneurysm in China: report of the first successful case. Surg Today 42:1219–1224

Huo Y, Luo T, Guccione JM, Teague SD, Tan W, Navia JA, Kassab GS (2013) Mild anastomotic stenosis in patient-specific CABG model may enhance graft patency: a new hypothesis. PLoS ONE 8:e73769

Jou LD, Saloner D (1998) A numerical study of magnetic resonance images of pulsatile flow in a two dimensional carotid bifurcation: a numerical study of MR images. Med Eng Phys 20:643–652

Kabinejadian F, Su B, Ghista DN, Ismail M, Kim S, Leo HL (2017) Sequential venous anastomosis design to enhance patency of arterio-venous grafts for hemodialysis. Comput Methods Biomech Biomed Eng 20:85–93

Les AS, Shadden SC, Alberto Figueroa C, Park JM, Tedesco MM, Herfkens RJ, Dalman RL, Taylor CA (2010) Quantification of hemodynamics in abdominal aortic aneurysms during rest and exercise using magnetic resonance imaging and computational fluid dynamics. Ann Biomed Eng 38:1288–1313

Liu X, Gao Z, Xiong H, Ghista D, Ren L, Zhang H, Wu W, Huang W, Hau WK (2016) Three-dimensional hemodynamics analysis of the circle of Willis in the patient-specific nonintegral arterial structures. Biomech Model Mechanobiol 15:1439–1456

Machi P, Ouared R, Brina O, Bouillot P, Yilmaz H, Vargas MI, Gondar R, Bijlenga P, Lovblad KO, Kulcsar Z (2019) Hemodynamics of focal versus global growth of small cerebral aneurysms. Clin Neuroradiol 29:285–293

Majeski J (2004) Replacement of in situ saphenous venous aneurysms with arterial autografts. Am J Surg 188:168–170

Marone LK, Clouse WD, Dorer DJ, Brewster DC, LaMuraglia GM, Watkins MT, Kwolek CJ, Cambria RP (2004) Preservation of renal function with surgical revascularization in patients with atherosclerotic renovascular disease. J Vasc Surg 39:322–329

Marrocco-Trischitta MM, van Bakel TM, Romarowski RM, de Beaufort HW, Conti M, van Herwaarden JA, Moll FL, Auricchio F, Trimarchi S (2018) The modified arch landing areas nomenclature (MALAN) improves prediction of stent graft displacement forces: proof of concept by computational fluid dynamics modelling. Eur J Vasc Endovasc Surg 55:584–592

Pandey P, Rayes M, Hong D, Guthikonda M, Xavier A (2011) Endovascular management of a giant aneurysm through saphenous vein graft after extracranial-intracranial bypass: case report and literature review. J Neurointerv Surg 3:361–363

Perktold K, Peter RO, Resch M, Langs G (1991) Pulsatile non-Newtonian blood flow in three-dimensional carotid bifurcation models: a numerical study of flow phenomena under different bifurcation angles. J Biomed Eng 13:507–515

Qiu Y, Wang Y, Fan YB, Peng LQ, Liu R, Zhao JC, Yuan D, Zheng TH (2019) Role of intraluminal thrombus in abdominal aortic aneurysm ruptures: a hemodynamic point of view. Med Phys 46:4263–4275

Shahcheraghi N, Dwyer HA, Cheer AY, Barakat AI, Rutaganira T (2002) Unsteady and three-dimensional simulation of blood flow in the human aortic arch. J Biomech Eng Trans ASME 124:378–387

Travis JA, Hansen KJ, Miller PR, Dean RH, Geary RL (2000) Aneurysmal degeneration and late rupture of an aortorenal vein graft: case report, review of the literature, and implications for conduit selection. J Vasc Surg 32:612–615

Tse KM, Chiu P, Lee HP, Ho P (2011) Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulations. J Biomech 44:827–836

Wen J, Yuan D, Wang QY, Hu Y, Zhao JC, Zheng TH, Fan YB (2016) A computational simulation of the effect of hybrid treatment for thoracoabdominal aortic aneurysm on the hemodynamics of abdominal aorta. Sci Rep 6:23801

Xiao N, Alastruey J, Figueroa CA (2014) A systematic comparison between 1-D and 3-D hemodynamics in compliant arterial models. Int J Numer Method Biomed Eng 30:204–231

Xu P, Liu X, Zhang H, Ghista D, Zhang D, Shi C, Huang W (2018) Assessment of boundary conditions for CFD simulation in human carotid artery. Biomech Model Mechanobiol 17:1581–1597

Zhang JM, Zhong L, Su B, Wan M, Yap JS, Tham JP, Chua LP, Ghista DN, Tan RS (2014) Perspective on CFD studies of coronary artery disease lesions and hemodynamics: a review. Int J Numer Method Biomed Eng 30:659–680

Zhao X, Liu Y, Li L, Wang W, Xie J, Zhao Z (2016) Hemodynamics of the string phenomenon in the internal thoracic artery grafted to the left anterior descending artery with moderate stenosis. J Biomech 49:983–991