Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods

Adam Chromy1,2,3, Ludek Zalud1,2,3, Petr Dobsak1, Igor Suskevic1, Veronika Mrkvicova4
1International Clinical Research Center, St. Anne's University Hospital Brno, Brno, Czech Republic
2Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
3Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic
4Department of Preventive Medicine, Faculty of Medicine, Masaryk University of Brno, Brno, Czech Republic

Tóm tắt

Limb volume measurements are used for evaluating growth of muscle mass and effectivity of strength training. Beside sport sciences, it is used e.g. for detection of oedemas, lymphedemas or carcinomas or for examinations of muscle atrophy. There are several commonly used methods, but there is a lack of clear comparison, which shows their advantages and limits. The accuracy of each method is uncertainly estimated only. The aim of this paper is to determine and experimentally verify their accuracy and compare them among each other. Water Displacement Method (WD), three methods based on circumferential measures—Frustum Sign Model (FSM), Disc Model (DM), Partial Frustum Model (PFM) and two 3D scan based methods Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) were compared. Precise reference cylinders and limbs of two human subjects were measured 10 times by each method. Personal dependency of methods was also tested by measuring 10 times the same object by 3 different people. Accuracies: WD 0.3 %, FSM 2–8 % according person, DM, PFM 1–8 %, MRI 2 % (hand) or 8 % (finger), CT 0.5 % (hand) or 2 % (finger);times: FSM 1 min, CT 7 min, WD, DM, PFM 15 min, MRI 19 min; and more. WD was found as the best method for most of uses with best accuracy. The CT disposes with almost the same accuracy and allows measurements of specific regions (e.g. particular muscles), as same as MRI, which accuracy is worse though, but it is not harmful. Frustum Sign Model is usable for very fast estimation of limb volume, but with lower accuracy, Disc Model and Partial Frustum Model is useful in cases when Water Displacement cannot be used.

Từ khóa


Tài liệu tham khảo

Akagi R, Takai Y, Ohta M, Kanehisa H, Kawakami Y, Fukunaga T (2009) Muscle volume compared to cross-sectional area is more appropriate for evaluating muscle strength in young and elderly individuals. Age Ageing 38:564–569. doi:10.1093/ageing/afp122 Armer JM, Ridner SH (2006) Measurement Techniques In Assessment Of Lymphedema. Lymph Link Artic Repr 18:1–4 Brijker F, Heijdra YF, Van Den Elshout FJ, Bosch FH, Folgering HT (2000) Volumetric measurements of peripheral oedema in clinical conditions. Clin Physiol Oxf Engl 20:56–61 Chlosta P, Drewa T, Siekiera J, Jaskulski J, Petrus A, Kamecki K, Mikolajczak W, Obarzanowski M, Wronczewski A, Krasnicki K, Jasinski M (2011) Lymph node dissection during laparoscopic (LRC) and open (ORC) radical cystectomy due to muscle invasive bladder urothelial cancer (pT2-3, TCC). Videosurgery Miniinvasive Tech 6:127–131. doi:10.5114/wiitm.2011.24689 Cmelik M, Machonsky L, Sima Z (2011) Fyzikalni tabulky. TU Liberec, Liberec Damstra RJ (2009) Diagnostic and THERAPEUTICAL ASPECTS OF LYMPHEDEMa. Stichting Lymfologie Centrum Nederland (SLCN) ; University Library, Universiteit Maastricht [host], Drachten; Maastricht De Santo NG, Bisaccia C, Cirillo M, Richet G (2011) Medicine in the Encyclopedie (1751–1780) of Diderot and d’Alembert. J Nephrol 24:S12–S24. doi:10.5301/JN.2011.6485 Deltombe T, Jamart J, Recloux S, Legrand C, Vandenbroeck N, Theys S, Hanson P (2007) Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema. Lymphology 40:26–34 Gaszynski T, Szewczyk T (2014) The influence of laparoscopic vs. open gastric bypass on hemodynamic function in morbidly obese patients during general anesthesia. Videosurgery Miniinvasive Tech 9:83–88. doi:10.5114/wiitm.2014.40988 Haase F, Siewert C, von Rautenfeld DB, Fischbach JU, Seifert H (2009) Comparison of different methods to quantify the volume of horse limbs. Berl Münch Tierärztl Wochenschr 122:126–131 Hackney KJ, Cook SB, Fairchild TJ, Ploutz-Snyder LL (2012) Skeletal muscle volume following dehydration induced by exercise in heat. Extreme Physiol Med 1:3. doi:10.1186/2046-7648-1-3 Haponiuk I, Chojnicki M, Steffens M, Jaworski R, Szofer-Sendrowska A, Juscinski J, Kwasniak E, Paczkowski K, Zielinski J, Gierat-Haponiuk K (2013) Miniinvasive interventional bridge to major surgical repair of critical aortic coarctation in a newborn with severe multiorgan failure. Videosurgery Miniinvasive Tech 8:244–248. doi:10.5114/wiitm.2011.33472 Herman GT (2009) Fundamentals of Computerized Tomography: Image Reconstruction from Projections, 2nd ed. 2010 edition. Springer, Dordrecht, New York Jamerson T (2009) Uncertainty example using simple propagation of uncertainty rules, The University of Mississippi [WWW Document]. http://www.phy.olemiss.edu/~thomas/weblab/221%20Miscellaneous%20folder/221_web_uncertainty/No_quad_uncertainty_fall_09.pdf Karakas P, Bozkir MG (2012) Anthropometric indices in relation to overweight and obesity among Turkish medical students. Arch Med Sci 8:209–213. doi:10.5114/aoms.2012.28546 Kaulesar Sukul DM, den Hoed PT, Johannes EJ, van Dolder R, Benda E (1993) Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. J Biomed Eng 15:477–480 Khanavi M, Sabbagh-Bani-Azad M, Abdolghaffari AH, Vazirian M, Isazadeh I, Rezvanfar MA, Baeeri M, Mohammadirad A, Rahimi R, Shams-Ardekani MR, Abdollahi M (2014) On the benefit of galls of Quercus brantii Lindl. in murine colitis: the role of free gallic acid. Arch Med Sci 6:1225–1234. doi:10.5114/aoms.2014.47831 Knarr BA, Ramsay JW, Buchanan TS, Higginson JS, Binder-Macleod SA (2013) Muscle volume as a predictor of maximum force generating ability in the plantar flexors post-stroke: measuring plantar flexor force post-stroke. Muscle Nerve 48:971–976. doi:10.1002/mus.23835 Konecny P (2013) Nove trendy v neurorehabilitaci [abstract]. In: Dobsak P (ed) Proceedings of the IV. Dny Fyzioterapie 11–12 October 2013. pp 7–7 Lavelle K, Stanton DB (2014) Measurement of Edema in the Hand Clinic, American Society of Hand Therapists [WWW Document]. http://www.researchgate.net/publication/257927122_American_Society_of_Hand_Therapists_TM_Key_Recommendations_for_Outcome_Evaluation_of_Edema_Measurement_of_Edema_in_the_Hand_Clinic_2_Conceptual_Basis_for_Testing_TestsMethods_Used_to_Measure_Edema Magnetic Resonance Imaging [WWW Document] (2010). URL http://www.mri-portal.com/clanky/magneticka_rezonance.php McCollough CH, Zink FE (1999) Performance evaluation of a multi-slice CT system. Med Phys 26:2223–2230 Megens AM, Harris SR, Kim-Sing C, McKenzie DC (2001) Measurement of upper extremity volume in women after axillary dissection for breast cancer. Arch Phys Med Rehabil 82:1639–1644. doi:10.1053/apmr.2001.26822 Meijer RS, Rietman JS, Geertzen JHB, Bosmans JC, Dijkstra PU (2004) Validity and intra- and interobserver reliability of an indirect volume measurements in patients with upper extremity lymphedema. Lymphology 37:127–133 Novelline RA, Squire LF (2004) Squire’s Fundamentals of Radiology. La Editorial, UPR Ramsay JW, Barrance PJ, Buchanan TS, Higginson JS (2011) Paretic muscle atrophy and non-contractile tissue content in individual muscles of the post-stroke lower extremity. J Biomech 44:2741–2746. doi:10.1016/j.jbiomech.2011.09.001 Ribeiro RCB, Lima SMPF, Carreira ACG, Masiero D, Chamlian TR (2010) Inter-tester reliability assessment of the volumetric measurement of the hand in subjects without any changes in their upper extremities. Acta Fisiatr 17:3–7 Ridner SH, Montgomery LD, Hepworth JT, Stewart BR, Armer JM (2007) Comparison of upper limb volume measurement techniques and arm symptoms between healthy volunteers and individuals with known lymphedema. Lymphology 40:35–46 Sander AP, Hajer NM, Hemenway K, Miller AC (2002) Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume. Phys Ther 82:1201–1212 Seidl Z, Vaněčková M (2007) Magnetická rezonance hlavy, mozku a páteře, Avicenum. ed. Grada Silva-Couto de MA, Prado-Medeiros CL, Oliveira AB, Alcantara CC, Guimaraes AT, Salvini de TF, Mattioli R, de Russo TL (2014) Muscle atrophy, voluntary activation disturbances, and low serum concentrations of IGF-1 and IGFBP-3 are associated with weakness in people with chronic stroke. Phys Ther 94:957–967. doi:10.2522/ptj.20130322 Slicer D (2015) [WWW Document]. http://www.slicer.org/ Spinczyk D (2014) Preparing the anatomical model for ablation of unresectable liver tumor. Videosurgery Miniinvasive Tech 9:246–251. doi:10.5114/wiitm.2014.43022 Sproule DM, Montgomery MJ, Punyanitya M, Shen W, Dashnaw S, Montes J, Dunaway S, Finkel R, Darras B, De Vivo DC, Kaufmann P (2011) Thigh muscle volume measured by magnetic resonance imaging is stable over a 6-month interval in spinal muscular atrophy. J Child Neurol 26:1252–1259. doi:10.1177/0883073811405053 Statni urad pro jadernou bezpecnost (2002) Vyhlaska O Radiacni Ochrane Szopinski T, Golabek T, Borowka A, Chlosta P (2014) Is determination of transition zone volume by transrectal ultrasound in patients with clinically benign prostatic enlargement sufficiently reliable in the clinical setting? Videosurgery Miniinvasive Tech 9:398–403. doi:10.5114/wiitm.2014.43128 Taylor R, Jayasinghe UW, Koelmeyer L, Ung O, Boyages J (2006) Reliability and validity of arm volume measurements for assessment of lymphedema. Phys Ther 86:205–214 Trends T, Read W, Jobs AR (2008) CT and radiation: What radiologists should know. Appl Radiol 37:22–29 Udupa JK, Herman GT (1999) 3D Imaging in Medicine, 2nd edn. CRC Press, Boca Raton. ISBN 9780849331794. https://www.crcpress.com/3D-Imaging-in-Medicine-Second-Edition/Udupa-Herman/9780849331794 Wachal K, Szmyt K, Oszkinis G (2014) Diagnosis and treatment of a patient with type IV endoleak as a late complication after endovascular aneurysm repair. Videosurgery Miniinvasive Tech 9:667–670. doi:10.5114/wiitm.2014.47264 Webb AR (2003) Introduction to biomedical imaging. Wiley, Hoboken