Lifespan of subcutaneous glucose sensors and their performances during dynamic glycaemia changes in rats

Journal of Biomedical Engineering - Tập 15 - Trang 457-463 - 1993
Elisabetta Bobbioni-Harsch1, Françoise Rohner-Jeanrenaud1, Milena Koudelka2, Nico de Rooij2, Bernard Jeanrenaud1
1Laboratoires de Recherches Métaboliques, Faculty of Medicine, Geneva, Switzerland
2Institut de Microtechnique de l'Université de Neuchâtel, Neuchâtel, Switzerland

Tài liệu tham khảo

Tchobroutsky, 1991, Blood glucose levels in diabetic and non-diabetic subjects, Diabetologia, 34, 67, 10.1007/BF00500374 Kilo, 1985, Value of glucose control in preventing complications of diabetes, Am J Med, 79A, 33, 10.1016/0002-9343(85)90583-2 Rosenstock, 1986, Early diabetic nephropathy: assessment and potential therapeutic interventions, Diabetes Care, 9, 529, 10.2337/diacare.9.5.529 Armour, 1990, Application of chronic intravascular blood glucose sensor in dogs, Diabetes, 39, 1519, 10.2337/diabetes.39.12.1519 Rebrin, 1989, Automated feedback control of subcutaneous glucose concentration in diabetic dogs, Diabetologia, 32, 573, 10.1007/BF00285330 Shichiri, 1983, Glycaeamic control in pancreatectomized dogs with a wearable artificial endocrine pancreas, Diabetologia, 24, 179, 10.1007/BF00250158 Matthews, 1988, An amperometric needle-type glucose sensor tested in rats and man, Diabet Med, 5, 248, 10.1111/j.1464-5491.1988.tb00978.x Moatti-Sirat, 1992, Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue, Diabetologia, 35, 224, 10.1007/BF00400921 Shichiri, 1986, Telemetry glucose monitoring device with needle-type glucose sensor: useful tool for blood glucose monitoring in diabetic individuals, Diabetes Care, 9, 298, 10.2337/diacare.9.3.298 Pickup, 1989, In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer, Diabetologia, 32, 213, 10.1007/BF00265097 Aalders, 1991, Development of a variable glucose sensor: studies in healthy and diabetic patients, Int J Artif Organs, 14, 102, 10.1177/039139889101400210 Pfeiffer, 1987, On the way to the automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosy future, Diabetologia, 30, 51 Gernet, 1989, Fabrication and characterization of a planar electrochemical cell and its application as a glucose sensor, Sensors and Actuators, 18, 59, 10.1016/0250-6874(89)87025-8 Koudelka, 1989, Planar amperometric enzyme-based glucose microelectrode, Sensors and Actuators, 18, 157, 10.1016/0250-6874(89)87015-5 Koudelka, 1989, In vivo response of microfabricated glucose sensor to glycemia changes in normal rats, Biomed Biochim Acta, 48, 953 Koudelka, 1991, In vivo behaviour of hypodermically implanted microfabricated glucose sensors, Biosensors and Bioelectronics, 6, 31, 10.1016/0956-5663(91)85005-H Velho, 1988, In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics, Diabetes, Nutrition and Metabolism, 3, 227 Koudelka M, Rohner-Jeanrenaud F, Bobbioni-Harsch E, de Rooij NF, Jeanrenaud B. A microfabricated glucose sensor: fabrication, characterization, in vitro and in vivo performances and related problems. Advances in Biosensors, in press, Fischer, 1987, Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs, Diabetologia, 30, 940, 10.1007/BF00295878 Jansson, 1988, Characterization by microdialysis of intercellular glucose level in subcutaneous tissue in humans, Am J Physiol, 255, E218 Rebrin, 1992, J Biomed Eng, 14, 33, 10.1016/0141-5425(92)90033-H