Les matériels d'ostéosynthèse résorbables

Annales de Chirurgie Plastique Esthétique - Tập 50 Số 6 - Trang 723-732 - 2005
D. Iera1, Anis Haddad1, George K.B. Sándor1, N. Ashmmakhi2
1Institute of biomaterials, Tampere university of technology, Tampere, Finland and department of surgery, Oulu university hospital, Oulu, Finland
2Department of Oral and Maxillofacial Surgery, University of Toronto, Toronto, Canada

Tóm tắt

Từ khóa


Tài liệu tham khảo

Gravallese, 1995, Loosening of a revision total hip replacement in a 60 year-old woman with longstanding rheumatoid arthritis, Arthritis Rheum., 38, 1315, 10.1002/art.1780380920

An, 1996, Prevention of bacterial adhesion to implant surfaces with a crosslinked abumin coating in vitro, J. Orthop. Res., 14, 846, 10.1002/jor.1100140526

Tonino, 1976, Protection from stress in bone and its effects, J. Bone Joint Surg. Br., 58, 107, 10.1302/0301-620X.58B1.1270486

Paavolainen, 1978, Effect of rigid plate fixation on structure and mineral content of cortical bone, Clin. Orthop., 136, 287

Antikainen, 1994, Development of the neurocranium after transsutural fixing by new, resorbable poly-L-lactide miniplates. A comparison to fixing with the common titanium miniplates, Acta Neurochir. (Wien.), 128, 26, 10.1007/BF01400649

Resnick, 1990, The effect of rigid internal fixation on cranial growth, Ann. Plast. Surg., 25, 372, 10.1097/00000637-199011000-00005

Wong, 1991, The effect of rigid fixation on growth of the neurocranium, Plast. Reconstr. Surg., 88, 395, 10.1097/00006534-199109000-00003

Wong, 1993, Craniofacial growth following rigid fixation: suture excision, miniplating, and microplating, J. Craniofac. Surg., 4, 234

Yaremchuk, 1994, The effect of rigid fixation on craniofacial growth in rhesus monkeys, Plast. Reconstr. Surg., 93, 1, 10.1097/00006534-199401000-00001

Fearon, 1995, Observations on the use of rigid fixation for craniofacial deformities in infants and young children, Plast. Reconstr. Surg., 95, 634, 10.1097/00006534-199504000-00002

Goldberg, 1995, Critical review of microfixation in pediatric craniofacial surgery, J. Craniofac. Surg., 6, 301, 10.1097/00001665-199507000-00008

Hönig, 1995, Passive and active intracranial translocation of osteosynthesis plates in adolescent minipigs, J. Craniofac. Surg., 6, 292, 10.1097/00001665-199507000-00006

Papay, 1995, “False” migration of rigid fixation appliances in pediatric craniofacial surgery, J. Craniofac. Surg., 6, 309, 10.1097/00001665-199507000-00010

Stelnicki, 1998, Intracranial migration of microplates versus wires in neonatal pigs after frontal advancement, J. Craniofac. Surg., 9, 60, 10.1097/00001665-199801000-00013

Yaremchuk, 1995, Symposium, resolving controversies related to plate and screw fixation in the growing craniofacial skeleton, J. Craniofac. Surg., 6, 525, 10.1097/00001665-199511000-00023

Yu, 1996, An experimental study of the effects of craniofacial growth on the long-term positional stability of microfixation, J. Craniofac. Surg., 7, 64, 10.1097/00001665-199601000-00014

Habal, 1998, Regeneration osteogenesis: the challenges that face bone graft surgery in the new millennium, Perspect. Plast. Surg., 11, 1

Ebraheim, 1990, Reduction of postoperative CT artifacts of pelvic fractures by use of titanium implants, Orthopedics, 13, 1357, 10.3928/0147-7447-19901201-06

Ebraheim, 1992, Magnetic resonance imaging after pedicular screw fixation of the spine, Clin. Orthop., 279, 133, 10.1097/00003086-199206000-00016

Habal, 1991, Editorial. J. Craniofac. Surg., 2, 55, 10.1097/00001665-199102020-00001

Sullivan, 1994, Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning, Plast. Reconstr. Surg., 94, 589, 10.1097/00006534-199410000-00004

Weese, 1984, Avoidance of artefacts on computerized tomograms by selection of appropriate surgical clips, Am. J. Surg., 147, 684, 10.1016/0002-9610(84)90142-9

Williams, 1979, Some observation on the role of cellular enzymes in the in vivo degradation of polymers, 61

Schneider, 1955

Kulkarni, 1966, Polylactic acid for surgical implants, Arch. Surg., 93, 839, 10.1001/archsurg.1966.01330050143023

Kulkarni, 1971, Biodegradable poly(lactic acid) polymers, J. Biomed. Mater. Res., 5, 169, 10.1002/jbm.820050305

Törmälä, 1998, Bioabsorbable polymers: materials technology and surgical applications, Proc. Inst. Mech. Eng. [H], 212, 101, 10.1243/0954411981533872

Frazza, 1971, A new absorbable suture, J. Biomed. Mater. Res. Symp., 1, 43, 10.1002/jbm.820050207

Getter, 1972, A biodegradable intraosseous appliance in the treatment of mandibular fractures, J. Oral Surg., 30, 344

Roed-Peterson, 1974, Absorbable synthetic suture material for internal fixation of fractures of the mandible., Int. J. Oral Biomed. Mater. Res., 3, 133

Illi, 1989, Résultats préliminaires de l'ostéosynthèse biodégradable en chirurgie craniofaciale chez l'enfant, Chir. Pediatr., 30, 284

Bos, 1987, Resorbable poly(L-lactide) plates and screws for fixation of zygomatic fractures, J. Oral Maxillofac. Surg., 45, 751, 10.1016/0278-2391(87)90194-7

Schmitt, 1969

Higgins, 1954

Vert, 1981, Stereoregular bioabsorbable polyesters for orthopaedic surgery, Makromol. Chem. Suppl., 5, 30, 10.1002/macp.1981.020051981103

Törmälä, 1992, Biodegradable self-reinforced composite materials: manufacturing structure and mechanical properties, Clin. Mater., 10, 29, 10.1016/0267-6605(92)90081-4

Vainionpää, 1986, Biodegradation of polyglycolic acid in bone tissue, an experimental study on rabbits, Arch. Orthop. Trauma Surg., 104, 333, 10.1007/BF00454425

Waris, 1994, Self-reinforced absorbable polylactide (SR-PLLA) plates in craniofacial surgery. A preliminary report on 14 patients, Eur. J. Plast. Surg., 17, 236, 10.1007/BF00208837

Törmälä, 1995, Ultra-high strength biodegradable polymeric composites for surgical applications, 1

Törmälä, 1988

Miller, 1977, Degradation rates of oral resorbable implants (polylactates and polyglyconates): rate modification with changes in PLA/PGA copolymer ratios, J. Biomed. Mater. Res., 11, 711, 10.1002/jbm.820110507

Weissberger, 1997, Resorbable fixation in the head and neck surgery, Laryngoscope, 107, 716, 10.1097/00005537-199706000-00003

Wiley, 1993

Tschakaloff, 1994

Pietrzak, 1997, Effect of simulated intraoperative heating and shaping on mechanical properties of a bioabsorbable fracture plate material, J. Biomed. Mater. Res., 38, 17, 10.1002/(SICI)1097-4636(199721)38:1<17::AID-JBM3>3.0.CO;2-K

Habal, 1999, Key points in the fixation of craniofacial skeleton with absorbable biomaterial, J. Craniofac. Surg., 10, 491, 10.1097/00001665-199911000-00008

Mäkelä, 1987, The effect of a penetrating biodegradable implant on the epiphyseal plate: an experimental study on growing rabbits with special regard to polyglactin 910, J. Pediatr. Orthop., 7, 415, 10.1097/01241398-198707000-00007

Mäkelä, 1988, The effect of trauma to the lower femoral epiphyseal plate. An experimental study in rabbits, J. Bone Joint Surg. Br., 70, 187, 10.1302/0301-620X.70B2.3346285

Mäkelä, 1989, The effect of a penetrating biodegradable implant on the growth plate. An experimental study on growing rabbits with special reference to polydioxanone, Clin. Orthop., 241, 300, 10.1097/00003086-198904000-00039

Mäkelä, 1990, Healing of physeal fracture after fixation with biodegradable self-reinforced polyglycolic acid pins. An experimental study on growing rabbits, Clin. Mater., 5, 1, 10.1016/0267-6605(90)90067-6

Eppley, 1992, Effects of resorbable fixation on craniofacial skeletal growth: a pilot experimental study, J. Craniofac. Surg., 3, 190, 10.1097/00001665-199212000-00003

Eppley, 1994, Effects of resorbable fixation on craniofacial skeletal growth: modifications in plate size, J. Craniofac. Surg., 5, 110, 10.1097/00001665-199405000-00012

Sinisaari, 1996, Metallic or absorbable implants for ankle fractures: a comparative study of infections in 3,111 cases, Acto Orthop. Scand., 67, 16, 10.3109/17453679608995602

Serlo, 2002, A new technique for cranial bone osteofixation: use of absorbable tacks and plates to fix parietal bone split grafts used for reconstruction of a post-traumatic frontal bone defect, J. Craniofac. Surg., 13, 331, 10.1097/00001665-200203000-00031

Leinonen, 2003, Holding power of bioabsorbable self-reinforced poly-L/D-lactide 70/30 tacks and miniscrews in human cadaver bone, J. Craniofac. Surg., 14, 171, 10.1097/00001665-200303000-00007

Tiainen, 2002, Comparison of the pull-out forces of bioabsorbable polylactide/glycolide screws (Biosorb and Lactosorb) and tacks: a study on the stability of fixation in human cadaver parietal bones, J. Craniofac. Surg., 13, 538, 10.1097/00001665-200207000-00012

Spanio, 2002, Use of new bioabsorbable tacks and a tack-shooter in cranial bone osteofixation saves operative time, J. Craniofac. Surg., 13, 693, 10.1097/00001665-200209000-00018

Sinisaari, 1996, Metallic or absorbable implants for ankle fractures: a comparative study of infections in 3,111 cases, Acta Orthop. Scand., 67, 16, 10.3109/17453679608995602

Ashammakhi, 2001, Developments in craniomaxillofacial surgery: use of self-reinforced polyglycolide and polylactide osteofixation devices, Plast. Reconstr. Surg., 108, 167, 10.1097/00006534-200107000-00027

Mainil-Varlet, 2001, Polylactide implants and bacterial contamination: an animal study, J. Biomed. Mater. Res., 54, 335, 10.1002/1097-4636(20010305)54:3<335::AID-JBM40>3.0.CO;2-4

Leinonen, 2002, Holding power of bioabsorbable ciprofloxacin-containing self-reinforced poly-L/DL-lactide 70/30 bioactive glass 13 miniscrews in human cadaver bone, J. Craniofac. Surg., 13, 212, 10.1097/00001665-200203000-00005

Nie, 1998, Use of bioabsorbable polymer for the delivery of ofloxacin during experimental osteomyelitis treatment, J. Orthop. Res., 16, 76, 10.1002/jor.1100160113

Overbeck, 1995, Penetration of ciprofloxacin into bone: a new bioabsorbable implant, J. Invest. Surg., 8, 155, 10.3109/08941939509023138

Tiainen, 2002, Bioabsorbable ciprofloxacin-containing and plain self-reinforced polylactide-polyglycolide 80/20 screws: pull-out strength properties in human cadaver parietal bones, J. Craniofac. Surg., 13, 427, 10.1097/00001665-200205000-00013

Wei, 1991, A bioabsorbable delivery system for antibiotic treatment of osteomyelitis. The use of lactic acid oligomer as a carrier, J. Bone Joint Surg. Br., 73, 246, 10.1302/0301-620X.73B2.2005148

Hofmann, 1995, Biodegradable implants in traumatology: a review on the state-of-the-art, Arch. Orthop. Trauma. Surg., 114, 123, 10.1007/BF00443385

Rozema, 1990, Influence of resorbable poly(L-lactide) bone plates and screws on the dose distributions of radiotherapy beams, Int. J. Oral Maxillofac. Surg., 19, 374, 10.1016/S0901-5027(05)80086-4

Hofmann, 1996, Postoperative irradiation treatment and bioresorbable implants in orthopaedic surgery: an experimental in vitro study, Biomaterials, 17, 1149, 10.1016/0142-9612(96)85918-7

Juutilainen, 1997, Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices, Arch. Orthop. Trauma. Surg., 116, 204, 10.1007/BF00393710

Böstman, 1994, Economic considerations on avoiding implant removals after fracture fixation by using absorbable devices, Scand. J. Soc. Med., 22, 41, 10.1177/140349489402200107

Juutilainen, 1995, Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices

Tharanon, 1998, Surgical outcomes using bioabsorbable plating systems in pediatric craniofacial surgery, J. Craniofac. Surg., 9, 441, 10.1097/00001665-199809000-00008

Jukkala-Partio, 2000, Treatment of subcapital femoral neck fractures with bioabsorbable or metallic screw fixation. A preliminary report, Ann. Chir. Gynaecol., 89, 45

Jukkala-Partio, 1998, Absorbable fixation of femoral head fractures. A prospective study of six cases, Ann. Chir. Gynaecol., 87, 44

Pelto-Vasenius, 1995, Fixation of scaphoid delayed union and non-union with absorbable polyglycolide pin or Herbert screw. Consolidation and functional results, Arch. Orthop. Trauma Surg., 114, 347, 10.1007/BF00448960

Habal, 1978, Repair of major cranio-orbital defects with an elastomer-coated mesh and autogenous bone paste, Plast. Reconstr. Surg., 61, 394, 10.1097/00006534-197803000-00014

Böstman, 1992, Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures, Clin. Orthop., 278, 193, 10.1097/00003086-199205000-00031

Rozema, 1990, Poly(L-lactide) implants in repair of defects of the orbital floor: An animal study, J. Oral Maxillofac. Surg., 48, 1305, 10.1016/0278-2391(90)90487-M

Santavirta, 1990, Immune response to polyglycolic acid implants, J. Bone Joint Surg. Br., 72, 597, 10.1302/0301-620X.72B4.2166048

Suuronen, 2000, Bioabsorbable plates and screws: current state of the art in facial fracture repair, Craniomaxillofac. Trauma., 6, 19

Peltoniemi, 2002, The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery, Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod., 94, 5, 10.1067/moe.2002.122160

Serlo, 2000, A new technique for correction of trigonocephaly in an infant: application of an absorbable endocranial plate, Childs Nerv. Syst., 16, 595, 10.1007/PL00007300

Serlo, 2001, Use of self-reinforced polylactide osteosynthesis devices in craniofacial surgery: a long-term follow-up study, Scand. J. Plast. Reconstr. Surg. Hand Surg., 35, 285, 10.1080/028443101750523195

Fuente del Campo, 1995, Placas de autofijacion interna absorbibles en la inmovilizacion de osteotomias maxilares, Revista Colombiana de Cirurgia Plastica y Reconstructiva, 4, 74

Fuente del Campo, 1995, Estabilidad a largo plazo con placas absorbibles para fijacion interna, Anales Medicos, 40, 54

Fuente del Campo, 1996, Fixation of horizontal maxillary osteotomies with biodegradable self-reinforced absorbable polylactide plates. Preliminary results, Eur. J. Plast. Surg., 19, 7, 10.1007/BF00209782

Haers, 1998, Biodegradable polylactic plates and screws in orthognathic surgery: technical note, J. Craniomaxillofac. Surg., 26, 87, 10.1016/S1010-5182(98)80045-0

Haers, 1998, Biodegradable self-reinforced ploy-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures, J. Craniomaxillofac. Surg., 26, 363, 10.1016/S1010-5182(98)80069-3

Suuronen, 1994, Sagittal ramus osteotomies fixed with biodegradable screws: a preliminary report, J. Oral Maxillofac. Surg., 52, 715, 10.1016/0278-2391(94)90484-7

Bergsma, 1995, Late degradation tissue response to poly(L-lactide) bone plates and screws, Biomaterials, 16, 25, 10.1016/0142-9612(95)91092-D

Bergsma, 1993, Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures, J. Oral Maxillofac. Surg., 51, 666, 10.1016/S0278-2391(10)80267-8

Koskikare, 1996, Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits, J. Biomed. Mater. Res., 30, 417, 10.1002/jbm.820300402

Peltoniemi, 1998, Intraosseous plating: a new method for biodegradable osteofixation in craniofacial surgery, J. Craniofac. Surg., 9, 171, 10.1097/00001665-199803000-00016

Serlo, 2003, A new technique for correction of trigonocephaly using bioabsorbable osteofixation tacks and plates and a novel tack-shooter, J. Craniofac. Surg., 14, 92, 10.1097/00001665-200301000-00017

Habal, 2001, Polymers and copolymers science in the operating room, J. Craniofac. Surg., 12, 407, 10.1097/00001665-200109000-00001

Tielinen L. The effect of bioabsorbable polylactide pins with polymer paste containing transforming growth factor-β1, on the healing of osteotomies and bone defects. An experimental study [PhD thesis]. Helsinki, Helsinki University; 2000.