Leg Axis After Computer-Navigated Total Knee Arthroplasty

Journal of Arthroplasty - Tập 20 Số 3 - Trang 282-288 - 2005
Ralf Decking1, Yma Markmann, Johannes Fuchs, W. Puhl, Hanns‐Peter Scharf
1Department of Orthopaedic Surgery, University of Ulm, RKU, 89081 Ulm, Germany.

Tóm tắt

Từ khóa


Tài liệu tham khảo

Windsor, 1989, Mechanisms of failure of the femoral and tibial components in total knee arthroplasty, Clin. Orthop., 246, 15

Lotke, 1977, Influence of positioning of prosthesis in total knee replacement, J. Bone Joint Surg. Am., 59, 77, 10.2106/00004623-197759010-00013

Oswald, 1993, Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty, J. Arthroplasty, 8, 419, 10.1016/S0883-5403(06)80042-2

Reed, 1997, The accuracy of femoral intramedullary guides in total knee arthroplasty, J. Arthroplasty, 12, 677, 10.1016/S0883-5403(97)90141-8

Teter, 1995, Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty, Clin. Orthop., 321, 106

Elloy, 1992, Accuracy of intramedullary alignment in total knee replacement, J. Biomed. Eng., 14, 363, 10.1016/0141-5425(92)90080-5

Cates, 1993, Intramedullary versus extramedullary femoral alignment systems in total knee replacement, Clin. Orthop., 286, 32, 10.1097/00003086-199301000-00007

Delp, 1998, Computer assisted knee replacement, Clin. Orthop., 354, 49, 10.1097/00003086-199809000-00007

Insall, 1989, Rationale of the knee society clinical rating system, Clin. Orthop., 248, 13, 10.1097/00003086-198911000-00004

Stucki, 1996, Evaluation of a German version of the WOMAC osteoarthritis index, Z. Rheumatol., 55, 40

Bernau, 1995

Ahlback, 1968, Osteoarthrosis of the knee. A radiographic investigation, Acta Radiol., Diagn., 277, 7

Krackow, 1999, A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA, Orthopedics, 22, 698

Saragaglia, 2001, Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study, Rev. Chir. Orthop. Reparatrice Appar. Mot., 87, 18

Kiefer, 2001, Computer-supported navigation in knee arthroplasty, Eur. J. Trauma, 1, 128

Jenny, 2001, Navigated implantation of total knee prostheses, Z. Orthop. Ihre Grenzgeb., 139, 117, 10.1055/s-2001-15041

Mielke, 2001, Navigation in knee arthroplasty—preliminary clinical experience and prospective comparative study in comparison with conventional technique, Z. Orthop. Ihre Grenzgeb., 139, 109, 10.1055/s-2001-15040

Sparmann, 2003, Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study, J. Bone Joint Surg. Br., 85, 830, 10.1302/0301-620X.85B6.13722

Swanson, 2000, Does axial limb rotation affect the alignment measurements in deformed limbs?, Clin. Orthop., 371, 246, 10.1097/00003086-200002000-00029

Wright, 1991, Measurement of lower limb alignment using long radiographs, J. Bone Joint Surg. Br., 73, 721, 10.1302/0301-620X.73B5.1894657

Laskin, 1990, Total condylar knee replacement in patients who have rheumatoid arthritis. A ten-year follow-up study, J. Bone Joint Surg. Am., 72, 529, 10.2106/00004623-199072040-00009

Insall, 1984

Ecker, 1987, Long term results after total condylar knee arthroplasty, Clin. Orthop., 216, 151, 10.1097/00003086-198703000-00023

Smith, 1989, Alignment of total knee arthroplasty, J. Arthroplasty, 4, S55, 10.1016/S0883-5403(89)80008-7

Bankes, 2003, The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement, Knee, 10, 55, 10.1016/S0968-0160(02)00050-9