Tóm tắt

Atrial stretch may contribute to the mechanism of atrial fibrillation (AF) recurrence after atrial fibrillation catheter ablation (AFCA). We tested whether the left atrial (LA) wall stress (LAW-stress[measured]) could be predicted by artificial intelligence (AI) using non-invasive parameters (LAW-stress[AI]) and whether rhythm outcome after AFCA could be predicted by LAW-stress[AI] in an independent cohort. Cohort 1 included 2223 patients, and cohort 2 included 658 patients who underwent AFCA. LAW-stress[measured] was calculated using the Law of Laplace using LA diameter by echocardiography, peak LA pressure measured during procedure, and LA wall thickness measured by customized software (AMBER) using computed tomography. The highest quartile (Q4) LAW-stress[measured] was predicted and validated by AI using non-invasive clinical parameters, including non-paroxysmal type of AF, age, presence of hypertension, diabetes, vascular disease, and heart failure, left ventricular ejection fraction, and the ratio of the peak mitral flow velocity of the early rapid filling to the early diastolic velocity of the mitral annulus (E/Em). We tested the AF/atrial tachycardia recurrence 3 months after the blanking period after AFCA using the LAW-stress[measured] and LAW-stress[AI] in cohort 1 and LAW-stress[AI] in cohort 2. LAW-stress[measured] was independently associated with non-paroxysmal AF (p < 0.001), diabetes (p = 0.012), vascular disease (p = 0.002), body mass index (p < 0.001), E/Em (p < 0.001), and mean LA voltage measured by electrogram voltage mapping (p < 0.001). The best-performing AI model had acceptable prediction power for predicting Q4-LAW-stress[measured] (area under the receiver operating characteristic curve 0.734). During 26.0 (12.0–52.0) months of follow-up, AF recurrence was significantly higher in the Q4-LAW-stress[measured] group [log-rank p = 0.001, hazard ratio 2.43 (1.21–4.90), p = 0.013] and Q4-LAW-stress[AI] group (log-rank p = 0.039) in cohort 1. In cohort 2, the Q4-LAW-stress[AI] group consistently showed worse rhythm outcomes (log-rank p < 0.001). A higher LAW-stress was associated with poorer rhythm outcomes after AFCA. AI was able to predict this complex but useful prognostic parameter using non-invasive parameters with moderate accuracy.

Từ khóa


Tài liệu tham khảo

Arnar, 2006, Familial aggregation of atrial fibrillation in Iceland., Eur. Heart J., 27, 708, 10.1093/eurheartj/ehi727

Augustin, 2020, The impact of wall thickness and curvature on wall stress in patient-specific electromechanical models of the left atrium., Biomech. Model Mechanobiol., 19, 1015, 10.1007/s10237-019-01268-5

Baek, 2016, Delayed recurrence of atrial fibrillation 2years after catheter ablation is associated with metabolic syndrome., Int. J. Cardiol., 223, 276, 10.1016/j.ijcard.2016.08.222

Betancur, 2018, Deep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT: A Multicenter Study., JACC Cardiovasc. Imag., 11, 1654, 10.1016/j.jcmg.2018.01.020

Burchfield, 2013, Pathological ventricular remodeling: mechanisms: part 1 of 2., Circulation, 128, 388, 10.1161/circulationaha.113.001878

Calkins, 2012, 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society., Heart Rhythm, 9, 632, 10.1016/j.hrthm.2011.12.016

Choi, 2017, Using recurrent neural network models for early detection of heart failure onset., J. Am. Med. Inform. Assoc., 24, 361, 10.1093/jamia/ocw112

Falsetti, 1970, Left ventricular wall stress calculated from one-plane cineangiography., Circ. Res., 26, 71, 10.1161/01.res.26.1.71

Feeny, 2020, Machine Learning of 12-Lead QRS Waveforms to Identify Cardiac Resynchronization Therapy Patients With Differential Outcomes., Circ. Arrhythm. Electrophysiol., 13, 10.1161/CIRCEP.119.008210

Firouznia, 2021, Machine Learning-Derived Fractal Features of Shape and Texture of the Left Atrium and Pulmonary Veins From Cardiac Computed Tomography Scans Are Associated With Risk of Recurrence of Atrial Fibrillation Postablation., Circ. Arrhythm. Electrophysiol., 14, 10.1161/CIRCEP.120.009265

John, 2010, Reverse remodeling of the atria after treatment of chronic stretch in humans: implications for the atrial fibrillation substrate., J. Am. Coll. Cardiol., 55, 1217, 10.1016/j.jacc.2009.10.046

Kim, 2018, 10-year nationwide trends of the incidence, prevalence, and adverse outcomes of non-valvular atrial fibrillation nationwide health insurance data covering the entire Korean population., Am. Heart J., 202, 20, 10.1016/j.ahj.2018.04.017

Kim, 2015, The ratio of early transmitral flow velocity (E) to early mitral annular velocity (Em) predicts improvement in left ventricular systolic and diastolic function 1 year after catheter ablation for atrial fibrillation., Europace, 17, 1051, 10.1093/europace/euu346

Kim, 2019, Clinical characteristics and rhythm outcome of catheter ablation of hemodynamically corrected valvular atrial fibrillation., J. Cardiol., 73, 488, 10.1016/j.jjcc.2018.10.014

Kim, 2015, Blunted rate-dependent left atrial pressure response during isoproterenol infusion in atrial fibrillation patients with impaired left ventricular diastolic function: a comparison to pacing., Europace, 17, ii89, 10.1093/europace/euv239

Kingma, 2014, Adam: A method for stochastic optimization., arXiv, 1412

Krittanawong, 2017, Artificial Intelligence in Precision Cardiovascular Medicine., J. Am. Coll. Cardiol., 69, 2657, 10.1016/j.jacc.2017.03.571

Kwon, 2020, Deep Learning-Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography., J. Am. Heart Assoc., 9, 10.1161/JAHA.119.014717

Kwon, 2020, Accuracy and clinical feasibility of 3D-myocardial thickness map measured by cardiac computed tomogram., International Journal of Arrhythmia, 21, 1, 10.1186/s42444-020-00020-w

Lee, 2021, Atrial Wall Thickness and Risk of Hemopericardium in Elderly Women After Catheter Ablation for Atrial Fibrillation., Circ. Arrhythm. Electrophysiol., 14, 10.1161/CIRCEP.120.009368

Marchese, 2012, Indexed left atrial volume is superior to left atrial diameter in predicting nonvalvular atrial fibrillation recurrence after successful cardioversion: a prospective study., Echocardiography, 29, 276, 10.1111/j.1540-8175.2011.01580.x

Nattel, 2002, New ideas about atrial fibrillation 50 years on., Nature, 415, 219, 10.1038/415219a

Nattel, 2008, Atrial remodeling and atrial fibrillation: mechanisms and implications., Circ. Arrhythm. Electrophysiol., 1, 62, 10.1161/circep.107.754564

Njoku, 2018, Left atrial volume predicts atrial fibrillation recurrence after radiofrequency ablation: a meta-analysis., Europace, 20, 33, 10.1093/europace/eux013

Pak, 2021, Sex differences in mapping and rhythm outcomes of a repeat atrial fibrillation ablation., Heart, 2020

Park, 2014, High left atrial pressures are associated with advanced electroanatomical remodeling of left atrium and independent predictors for clinical recurrence of atrial fibrillation after catheter ablation., Heart Rhythm, 11, 953, 10.1016/j.hrthm.2014.03.009

Park, 2009, The relationship between endocardial voltage and regional volume in electroanatomical remodeled left atria in patients with atrial fibrillation: comparison of three-dimensional computed tomographic images and voltage mapping., J Cardiovasc Electrophysiol, 20, 1349, 10.1111/j.1540-8167.2009.01557.x

Park, 2019, Atrial Fibrillation Catheter Ablation Increases the Left Atrial Pressure., Circ. Arrhythm. Electrophysiol., 12, 10.1161/CIRCEP.118.007073

Pouleur, 1993, Changes in ventricular volume, wall thickness and wall stress during progression of left ventricular dysfunction. The SOLVD Investigators., J. Am. Coll. Cardiol., 22, 43A, 10.1016/0735-1097(93)90462-A

Takeuchi, 2006, Disorganization of gap junction distribution in dilated atria of patients with chronic atrial fibrillation., Circ J, 70, 575, 10.1253/circj.70.575

Tops, 2011, Left atrial strain predicts reverse remodeling after catheter ablation for atrial fibrillation., J. Am. Coll. Cardiol., 57, 324, 10.1016/j.jacc.2010.05.063

Verma, 2011, Canadian Cardiovascular Society atrial fibrillation guidelines 2010: catheter ablation for atrial fibrillation/atrial flutter., Can J. Cardiol., 27, 60, 10.1016/j.cjca.2010.11.011

Wang, 2011, Left atrial wall tension directly affects the restoration of sinus rhythm after Maze procedure., Eur. J. Cardiothorac. Surg., 40, 77, 10.1016/j.ejcts.2010.10.022

Yu, 2017, Pulmonary Vein Isolation Alone Versus Additional Linear Ablation in Patients With Persistent Atrial Fibrillation Converted to Paroxysmal Type With Antiarrhythmic Drug Therapy: A Multicenter, Prospective, Randomized Study., Circ. Arrhythm. Electrophysiol., 2017

Zhuang, 2012, Association between left atrial size and atrial fibrillation recurrence after single circumferential pulmonary vein isolation: a systematic review and meta-analysis of observational studies., Europace, 14, 638, 10.1093/europace/eur364