Leaching behaviour of different scrap materials at recovery and recycling companies: Full-, pilot- and lab-scale investigation

Waste Management - Tập 34 Số 12 - Trang 2674-2686 - 2014
Eva Blondeel1, Michael Chys2, Veerle Depuydt3, Karel Folens4, Gijs Du Laing4, A.R.D. Verliefde5, Stijn Van Hulle6
1LIWET, Department of Industrial Biological Sciences, Ghent University, Graaf Karel de Goedelaan 5, B-8500 Kortrijk, Belgium
2LIWET, Department of Industrial Biological Sciences, Ghent University, Graaf Karel de Goedelaan 5, B-8500 Kortrijk, Belgium; BIOMATH, Department of Mathematical Modeling, Statistics and Bioinformatics, Ghent University, Coupure Links 653, B-9000 Gent, Belgium.
3Flanders Knowledge Centre Water (Vlakwa vzw), Graaf Karel de Goedelaan 34, B-8500 Kortrijk, Belgium.
4Ecochem, Department of Applied Analytical and Physical Chemistry, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Gent, Belgium.
5PaInT, Department of Applied Analytical and Physical Chemistry, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Gent, Belgium; Department of Sanitary Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, NL-2628CN Delft, The Netherlands.
6LIWET, Department of Industrial Biological Sciences, Ghent University, Graaf Karel de Goedelaan 5, B-8500 Kortrijk, Belgium; BIOMATH, Department of Mathematical Modeling, Statistics and Bioinformatics, Ghent University, Coupure Links 653, B-9000 Gent, Belgium. Electronic address: [email protected].

Tóm tắt

Từ khóa


Tài liệu tham khảo

Ballschmiter, 1980, Analysis of polychlorinated-biphenyls (PCB) by glass-capillary gas-chromatography, Fresenius’ J. Anal. Chem., 302, 20, 10.1007/BF00469758

Boogaard, 2004

Bouvrette, 2006, Analysis of the 16 Environmental Protection Agency priority polycyclic aromatic hydrocarbons by high performance liquid chromatography-oxidized diamond film electrodes, J. Chromatogr. A, 1103, 248, 10.1016/j.chroma.2005.11.028

Boxall, 1997, The effects of motorway runoff on freshwater ecosystems. 3. Toxicant confirmation, Arch. Environ. Contam. Toxicol., 33, 9, 10.1007/s002449900216

Chys, 2013, Treatment of rainwater runoff in recovery and recycling companies: lab and pilot-scale testing, J. Environ. Sci. Health. Part A Toxic/Hazard. Subst. Environ. Eng., 48, 446, 10.1080/10934529.2013.729912

Clesceri, 1998

Davis, 2001, Loading estimates of lead, copper, cadmium, and zinc in urban runoff from specific sources, Chemosphere, 44, 997, 10.1016/S0045-6535(00)00561-0

Kolias, 2014, Assessment of toxic metals in waste personal computers, Waste Manage., 34, 1480, 10.1016/j.wasman.2014.04.020

Legret, 1999, Evaluation of pollutant loadings in the runoff waters from a major rural highway, Sci. Total Environ., 235, 143, 10.1016/S0048-9697(99)00207-7

Luo, 2011, Heavy metal contamination in soils and vegetables near an e-waste processing site, South China, J. Hazard. Mater., 186, 481, 10.1016/j.jhazmat.2010.11.024

Mangani, 2005, Evaluation of the pollutant content in road runoff first flush waters, Water Air Soil Pollut., 160, 213, 10.1007/s11270-005-2887-9

Maragkos, 2013, Qualitative and quantitative determination of heavy metals in waste cellular phones, Waste Manage., 33, 1882, 10.1016/j.wasman.2013.05.016

Mckenzie, 2009, Metals associated with stormwater-relevant brake and tire samples, Sci. Total Environ., 407, 5855, 10.1016/j.scitotenv.2009.07.018

Prabhukumar, 2010

Sebag, 2009, Evaluation of environmental compatibility of EAFD using different leaching standards, J. Hazard. Mater., 166, 670, 10.1016/j.jhazmat.2008.11.125

Swamikannu, X., 1994. Auto Recycler and Dismantler Facilities: Environmental Analysis of the Industry with a Focus on Storm Water Pollution. PhD thesis. University of California.

Tchobanoglous, 2003

U.S. Environmental Protection Agency (US-EPA), 1992. Toxicity Characteristic Leaching Procedure (TCLP) Test Method 1311. Specifications of the Committee on Analytical Reagents of the American Chemical.

Vahid, 2013, Evaluation of the metalwork cutting fluid treatment performance using fenton oxidation process in comparison with coagulation-flocculation, Caspian J. Appl. Sci. Res., 2, 90

Van Larebeke, 1999, The Belgian PCB and dioxin incident of January–June 1999: exposure data and potential impact on health, Environ. Health Perspect., 109, 265

Verachtert, E., Polders, C., Van Den Abeele, L., Huybrechts, D., 2014. Beste Beschikbare Technieken (BBT) voor verontreinigd hemelwater voor de afvalopslag sector. Vlaams Kenniscentrum voor Beste Beschikbare Technieken (VITO) (In Dutch).

Zhou, 2013, Leaching characteristics of heavy metals and brominated flame retardants from waste printed circuit boards, J. Hazard. Mater., 246, 96, 10.1016/j.jhazmat.2012.11.065