La définition de la resténose vue par le clinicien : aspects méthodologiques et angiographiques
Tài liệu tham khảo
Serruys, 1988, Incidence of restenosis after successful angioplasty : a time-related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3 and 4 months, Circulation, 77, 361, 10.1161/01.CIR.77.2.361
Noyuboshi, 1988, Restenosis after successful percutaneous transluminal coronary angioplasty. Serial angiographic follow-up of 299 patients, J Am Coll Cardiol, 12, 616, 10.1016/S0735-1097(88)80046-9
Serruys, 1994, A comparison of ballon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease, N Engl J Med, 331, 489, 10.1056/NEJM199408253310801
Fischman, 1994, A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease, N Engl J Med, 331, 496, 10.1056/NEJM199408253310802
Morice, 2002, A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization, N Engl J Med, 346, 1773, 10.1056/NEJMoa012843
Park, 2003, A paclitaxel-eluting stent for the prevention of coronary restenosis, N Engl J Med, 348, 1537, 10.1056/NEJMoa021007
Califf, 1990, Restenosis : the clinical issues, 363
Laarman, 1990, Assessment of « silent » restenosis and long-term follow-up after successful angioplasty in single vessel coronary artery disease: the value of qualitative excercise electrocardiographiy and quantitative coronary angiography, J Am Coll Cardiol, 16, 578, 10.1016/0735-1097(90)90346-Q
de Feyter, 1991, Quantitative coronary angiography to measure progression and regression of coronary atherosclerosis, Circulation, 84, 412, 10.1161/01.CIR.84.1.412
Fleming, 1991, Patterns in visual interpretation of coronary angiograms as detected by quantitative angiography, J Am Coll Cardiol, 18, 945, 10.1016/0735-1097(91)90752-U
Reiber, 1985, Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assissted quantification of coronary angiograms, Circulation, 71, 280, 10.1161/01.CIR.71.2.280
Beatt, 1988, Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilatation, J Am Coll Cardiol, 12, 315, 10.1016/0735-1097(88)90400-7
Serruys, 1991, Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2 receptor blockade. A randomized, double blind, placebo controlled trial, Circulation, 84, 1568, 10.1161/01.CIR.84.4.1568