Is a Type II Endoleak after EVAR a Harbinger of Risk? Causes and Outcome of Open Conversion and Aneurysm Rupture during Follow-up

European Journal of Vascular and Endovascular Surgery - Tập 27 Số 2 - Trang 128-137 - 2004
Corine J. van Marrewijk1, Gerdine A. J. Fransen1, Robert J.F. Laheij1, Peter L. Harris1, Jacob Buth1, for the EUROSTAR Collaborators1
1Catharina Hospital, P.O.Box 1350, 6502 ZA Eindhoven, The Netherlands

Tóm tắt

Từ khóa


Tài liệu tham khảo

Buth, 2000, Early complications and endoleaks after endovascular abdominal aortic aneurysm repair. Report of a multicenter study, J Vasc Surg, 31, 134, 10.1016/S0741-5214(00)70075-9

White, 1996, Endoleak—a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft, J Endovasc Surg, 3, 124, 10.1583/1074-6218(1996)003<0124b:>2.0.CO;2

Matsumura, 1998, Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm, J Vasc Surg, 27, 606, 10.1016/S0741-5214(98)70224-1

Alimi, 1998, Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction, J Vasc Surg, 28, 178, 10.1016/S0741-5214(98)70213-7

Torsello, 1998, Rupture of abdominal aortic aneurysm previously treated by endograft stent-graft, J Vasc Surg, 28, 184, 10.1016/S0741-5214(98)70214-9

May, 1999, Rupture of abdominal aortic aneurysms: a concurrent comparison of outcome of those occurring after endoluminal repair versus those occurring de novo, Eur J Vasc Endovasc Surg, 18, 344, 10.1053/ejvs.1999.0899

White, 2000, Abdominal aortic aneurysm rupture following endoluminal graft development: report of a predictable event, J Endovasc Ther, 7, 257, 10.1177/152660280000700401

Harris, 2000, Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience, J Vasc Surg, 32, 739, 10.1067/mva.2000.109990

van Marrewijk, 2002, Significance of endoleaks after endovascular repair of abdominal aortic aneurysms. The EUROSTAR experience, J Vasc Surg, 35, 461, 10.1067/mva.2002.118823

Buth, 2002, Causes and outcomes of open conversion and aneurysm rupture after endovascular aortic aneurysm repair. Can type II endoleaks be dangerous?, J Am Coll Surg, 194, 98, 10.1016/S1072-7515(01)01128-0

Resch, 1998, Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter, J Vasc Surg, 28, 242, 10.1016/S0741-5214(98)70160-0

Baum, 2002, Treatment of type II endoleaks after endovascular repair of abdominal aortic aneurysms. Comparison of transarterial and translumbar techniques, J Vasc Surg, 35, 23, 10.1016/S0741-5214(02)32021-4

Laheij, 2000, Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate term follow-up results of a European collaborative registry (EUROSTAR), Br J Surg, 87, 1666, 10.1046/j.1365-2168.2000.01661.x

Cuypers, 2000, Which factors increase the risk of conversion to open surgery following endovascular abdominal aortic aneurysm repair?, Eur J Vasc Endovasc Surg, 20, 183, 10.1053/ejvs.2000.1167

Moore, 1996, Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase I trial, J Vasc Surg, 23, 543, 10.1016/S0741-5214(96)80032-2

White, 1996, Historic control comparison of outcome for endoluminal versus open repair of abdominal aortic aneurysms, J Vasc Surg, 23, 201, 10.1016/S0741-5214(96)70264-1

Brewster, 1998, Initial experience with endovascular aneurysm repair: comparison of early results with outcome of conventional open repair, J Vasc Surg, 27, 992, 10.1016/S0741-5214(98)70002-3

Zarins, 1999, AneuRx stentgrafts vs. open surgical repair of abdominal aortic aneurysms: multicenter prospective clinical trial, J Vasc Surg, 29, 292, 10.1016/S0741-5214(99)70382-4

Arko, 2002, Aneurysm-related death. Primary endpoint analysis for comparison of open and endovascular repair, J Vasc Surg, 36, 297, 10.1067/mva.2002.126314

Mohan, 2001, Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair, Eur J Vasc Endovasc Surg, 21, 344, 10.1053/ejvs.2000.1341

Laheij, 2001, The evolving technique of endovascular stenting of abdominal aortic aneurysm. Time for reappraisal, Eur J Vasc Endovasc Surg, 22, 436, 10.1053/ejvs.2001.1500

Yarnell, 2001, Lifestyle factors and coagulation activation markers. The Carphilly study, Blood Coagul Fibrinolysis, 12, 721, 10.1097/00001721-200112000-00015

Fairman, 2002, Potential impact of the therapeutic Warfarin treatment on type II endoleaks and sac shrinkage rates on midterm follow-up examination, J Vasc Surg, 35, 679, 10.1067/mva.2002.121570

Görich, 2000, Embolization of type II endoleaks fed by the inferior mesenteric artery using the superior mesenteric artery approach, J Endovasc Ther, 7, 297, 10.1177/152660280000700407

Schurink, 1998, Endoleakage after stent-graft treatment of abdominal aneurysm. Implications on pressure and imaging—an in vitro study, J Vasc Surg, 28, 234, 10.1016/S0741-5214(98)70159-4

Resnikoff, 1996, Faith of the excluded abdominal aortic aneurysm sac: long-term follow-up of 831 patients, J Vasc Surg, 24, 851, 10.1016/S0741-5214(96)70022-8

White, 2001, Failed AAA endograft exclusion due to type II endoleak: explant analysis, J Endovasc Ther, 8, 254, 10.1177/152660280100800304

Fan, 2001, Endovascular stent-graft in abdominal aortic aneurysms. The relationship between patent vessels that arise from the aneurysmal sac and early endoleak, Radiology, 218, 176, 10.1148/radiology.218.1.r01ja30176

Görig, 2001, Endoleaks after endovascular repair of aortic aneurysm. Are they predictable? Initial results, Radiology, 218, 477, 10.1148/radiology.218.2.r01fe13477

Gould, 2001, Aortic side branch embolization before endovascular aneurysms repair. Incidence of type II endoleak, J Vasc Interv Radiol, 12, 337, 10.1016/S1051-0443(07)61913-7

Liewald, 2001, Influence of treatment of type II leaks on the aneurysm surface area, Eur J Vasc Endovasc Surg, 21, 339, 10.1053/ejvs.2001.1333

Marty, 1998, Endoleak after endovascular graft repair of experimental aortic aneurysms. Does coil embolisation with angiographic ‘seal’ lower intraaneurysmal pressure?, J Vasc Surg, 27, 454, 10.1016/S0741-5214(98)70320-9

Mehta, 2001, All sealed endoleaks are not the same. A treatment strategy based on an ex vivo analysis, Eur J Vasc Endovasc Surg, 21, 541, 10.1053/ejvs.2001.1349

Dattilo, 2002, Clinical failures of endovascular abdominal aortic aneurysm repair. Incidence, causes, and management, J Vasc Surg, 35, 1137, 10.1067/mva.2002.124627

Wolf, 2000, Rate of change in abdominal aortic aneurysm diameter after endovascular repair, J Vasc Surg, 32, 108, 10.1067/mva.2000.107754

Rhee, 2000, Long-term fate of the aneurysmal sac following endovascular exclusion of abdominal aortic aneurysms, J Vasc Surg, 32, 689, 10.1067/mva.2000.110172

May, 1997, Conversion from endoluminal to open repair of abdominal aortic aneurysms. A hazardous procedure, Eur J Vasc Endovasc Surg, 14, 4, 10.1016/S1078-5884(97)80218-3

Faries, 2002, A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms, J Vasc Surg, 35, 1123, 10.1067/mva.2002.123324