Investigations on serviceability control of long-span structures under human-induced excitation

Springer Science and Business Media LLC - Tập 11 Số 1 - Trang 57-71 - 2012
Xin Chen1, Youliang Ding1, Zhiqiang Zhang2, Peng Sun2, Aiqun Li2
1Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education, Southeast University, Nanjing, 210096, China
2Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education, Southeast University, Nanjing, China

Tóm tắt

Từ khóa


Tài liệu tham khảo

British Standards Institution (1996), BS6399: 1 Loading for buildings, London.

Brownjohn J and Middleton CT (2008), “Procedures for Vibration Serviceability Assessment of High-frequency Floors,” Engineering Structures, 30(6): 1548–1559.

Canadian Standards Association (1989), CSA Standard CAN 3-S16 1-M 89. Steel Structures for Buildings-limit State Design, Appendix G.

Chen X, Li AQ, Zhang ZQ, et al. (2010), “Design and Analysis on Vibration Control of Long-span Floor in Large Station Room under Stochastic Crowd-induced Excitation,” Journal of Southeast University (Natural Science Edition), 40(3): 543–547. (in Chinese)

Collette FS (2002), “Turned Mass Dampers for a Suspended Structure of Foot Bridges and Meeting Boxes,” Proceedings of the International Conference on the Design and Dynamic Behaviour of Footbridges, Paris, France, November 20–22, 2002.

Dallard P, Fitzpatrick AJ, Flint A, et al. (2001), “The London Millennium Footbridge,” Structural Engineer, 79(22): 17–33.

Ellingwood B and Tallin A (1984), “Structural Serviceability: Floor Vibrations,” Journal of Structural Engineering, 110(2): 401–418.

Hicks SJ and Devine PJ (2004), “Design Guide on the Vibration of Floors in Hospitals,” SCI.

Huang RX and Li AQ (2010), “MTMD Control of Windinduced Vibration of High-rise Structures,” Journal of Huazhong University of Science and Technology (Nature Science Edition), 38(4): 109–112. (in Chinese)

Huang Z, Li AQ and Liu KA, et al. (2009), Helical Pores Viscous Damper: R.P. China, Patent No. CN101555922.

Iván MD and Reynolds P (2010), “Acceleration Feedback Control of Human-induced Floor Vibrations,” Engineering Structures, 32(1): 163–173.

Jerome J (2003), Connor. Introduction to Structural Motion Control, New Jersey, US: Person Education, Inc.

Kuhlmann W and Butz C (2009), “The Increasing Comfort of Footbridges with Mass Dampers is Exemplary Shown with the August-wilhelm-steg in Oranien-burg, Germany,” STAHLBAU, 78(7): 484–491.

Li CX (2000), “Performance of Multiple Tuned Mass Dampers for Attenuating Undesirable Oscillations of Structures Under the Ground Acceleration,” Earthquake Engineering and Structural Dynamics, 29: 1405–1421.

Li CX (2002), “Optimum Multiple Tuned Mass Dampers for Structures Under the Ground Acceleration Based on DDMF and ADMF,” Earthquake Engineering and Structural Dynamics, 31: 897–919.

Li AQ, Chen X and Zhang ZQ (2010b), “Design and Analysis on Vibration Control of Long-span Floor Structures,” Journal of Building Structures, 31(6): 160–170. (in Chinese)

Li AQ, Huang Z and Liu KA, et al. (2009), Controllable Viscous Damper: R.P. China, Patent No. CN101576139.

Li AQ, Huang Z, Liu KA, et al. (2010a), Viscous Damper with Adjustable Damping Force: R. P. China, Patent No. CN201396390.

Murray TM, Allen DE and Ungar EE (1997), Floor Vibrations due to Human Activity, American Institute of Steel Inc., Chicago, Illinois: USA.

Murray TM, Allen DE and Ungar EE (2003), Floor Vibrations due to Human Activity, American Institute of Steel Inc., Chicago, Illinois: USA.

Pavic A and Willford M (2005), CSTR43, Appendix G-Vibration Serviceability of Post-tensioned Concrete Floors, The Concrete Society.

Qin L, Yan WM, Hu XJ, et al. (2009), “Study on Seismic Control Effectiveness of TMD System of Symbolic Tower of Henan Art Center,” Journal of Beijing University of Technology, 35(6): 761–768. (in Chinese)

Saidi I, Gad EF, Wilson JL, et al. (2011), “Development of Passive Viscoelastic Damper to Attenuate Excessive Floor Vibrations,” Engineering Structure, (Available online)

Song ZG and Jin WL (2004), “Peak Acceleration Response Spectrum of Long-span Floor Vibration by Pedestrian Excitation,” Journal of Building Structures, 25(2): 57–63. (in Chinese)

Trada Technology (1998), Guidance Document 6: Vibration in Timber Floors.

Wendell DV and Ronaldo CB (2011) “Control of Vibrations Induced by People Walking on Large Span Composite Floor Decks” Engineering Structures, 33(9): 2485–2494.

Willford M and Young P (2006), A Design Guide for Footfall Induced Vibration of Structures, The Concrete Society.

Wyatt TA (1989), Design Guide on the Vibration of Floors, SCI.

Xu QY, Li AQ, Zhang ZQ, et al. (2008), “Vibration Control of a Long-span Suspended Structure Considering Human Comfort,” Journal of Vibration and Shock, 27(4): 139–142. (in Chinese)

Ye ZQ, Li AQ, Ding YL, et al. (2003), “The Vibration Energy Dissipation Design of a Pedestrian Bridge (1),” Special Structures, 20(1): 68–70. (in Chinese)

Zhang ZQ, Li AQ and Liu KA (2010), A Suspension Tuned Mass Damper: R.P. China, Patent No. CN101806104.

Zivanovic S, Pavic A and Reynolds P (2005), “Vibration Serviceability of Footbridges under Human-induced Excitation: a Literature Review,” Journal of Sound and Vibration, 279(1–2): 1–74.