Introducing a Novel Analysis Technique for Osseointegrated Dental Implants Retrieved 29 Years Postsurgery

Clinical Implant Dentistry and Related Research - Tập 15 Số 4 - Trang 538-549 - 2013
Hamid Sarve1, Bertil Friberg2, Gunilla Borgefors3, Carina B. Johansson4
1PhD student, Centre for Image Analysis, Swedish University of Agricultural Sciences, Uppsala, Sweden
2associate professor, Brånemark Clinic, Göteborg, Sweden
3professor, Centre for Image Analysis, Swedish University of Agricultural Sciences, Uppsala, Sweden
4professor, Institute of Odontology, Department of Prosthodontics/Dental Materials Science, University of Gothenburg, Göteborg, Sweden

Tóm tắt

ABSTRACTPurpose: To investigate osseointegration of oral implants, which were retrieved from a patient after 29 years in situ, we use novel three‐dimensional analysis methods and visualization techniques that supplement conventional two‐dimensional analysis.Materials and Methods: The sample processing involved nondecalcification and embedment in resin. Conventional two‐dimensional histomorphometrical methods were conducted. Additionally, the quantification was extended to three‐dimensional by using synchrotron radiation micro‐computed tomography (SRµCT) technique and two relevant visualization methods for the three‐dimensional data were introduced.Results: The three‐dimensional results involved three‐dimensional quantification and visualization of two implant samples with methods beyond state‐of‐the‐art. Traditional two‐dimensional histomorphometrical results revealed a mean bone‐implant contact (BIC) of about 50%. In most samples, bone area (BA) was lower inside the treads compared with out‐folded mirror images, which were confirmed by the three‐dimensional quantification. The BIC along four selected regions showed highest percentages in the bottom/valley region and lowest in the thread‐peak region. Qualitative observations revealed ongoing bone remodeling areas in all samples. The apical hole demonstrated high osseointegration.Conclusion: The novel techniques including an animation and an out‐folding of BIC and BA enabled a simultaneous visualization of the three‐dimensional material obtained from SRµCT data. However, the two‐dimensional histological sections were needed for qualitative and quantitative evaluation of osseointegration and, thus, both methods are considered equally important.

Từ khóa


Tài liệu tham khảo

10.1016/j.ijom.2007.11.019

10.1111/j.1600-0501.2004.01031.x

10.1563/765.1

Bolind P, 2005, A study of 275 retrieved Brånemark oral implants, Int J Periodontics Restorative Dent, 05, 425

Rebaudi A, 2004, Microcomputed tomographic analysis of the peri‐implant bone, Int J Periodontics Restorative Dent, 24, 316

10.1111/j.1708-8208.2005.tb00051.x

Butz F, 2006, Three‐dimensional bone‐implant integration profiling using micro‐computed tomography, Int J Oral Maxillofac Implants, 21, 687

10.1007/s12541-010-0093-1

10.22203/eCM.v007a05

Weiss P, 2005, Synchrotron and non synchrotron X‐ray microtomography threedimensional representation of bone ingrowth in calcium phosphate biomaterials, Eur Cell Mater, 9, 48

10.1111/j.1600-051X.2008.01283.x

10.1111/j.1600-0714.1982.tb00172.x

10.1016/0142-9612(95)98268-J

10.1034/j.1600-0501.1991.020103.x

10.1148/rg.246045065

10.1007/978-3-642-02230-2_79

10.1016/j.biomaterials.2007.01.022

10.1007/978-3-642-15907-7_30

10.1016/j.cmpb.2010.12.011

10.1111/j.1600-051X.2008.01277.x

Lekholm U, 1985, Tissue integrated prostheses – osseointegration in clinical dentistry, 233