Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects

Physiotherapy Research International - Tập 2 Số 3 - Trang 150-166 - 1997
Lucie Brosseau1, Michel Tousignant1, Julie Budd2, Nathalie Chartier2, Louise Duciaume2, Sherry Plamondon2, Joseph P. O’Sullivan3, Shayne O'Donoghue4, Suzanne Balmer5
1(School of Rehabilitation Sciences, University of Ottawa, Ontario, Canada)
2Physiotherapy Private Practice, Ontario, Canada.
3Department of Radiology, Ottawa General Hospital, Ontario, Canada.
4Department of Physiotherapy, Ottawa General Hospital, Ontario, Canada.
5Physiotherapy Department, The Rehabilitation Centre of The Royal Ottawa Health Care Group, Ottawa, Ontario, Canada.

Tóm tắt

AbstractBackground and Purpose

A new parallelogram goniometer was designed by the Rehabilitation Centre of the Royal Ottawa Health Care Group in 1983. The advantage of using such a goniometer is that the clinician is not required to estimate the joint axis of rotation when taking a measurement. The parallelogram goniometer has obtained a good intratester and intertester reliability when measuring active range of motion of hip abduction on eight individuals with hip pathologies. However, the validity of the parallelogram goniometer has not been examined. The purposes of this study were to examine the intratester and intertester reliability and the criterion validity of the parallelogram and universal goniometers for active knee flexion on healthy individuals.

Subjects

Sixty healthy university students (44 females and 16 males; mean age of 20.6 yrs.) participated to this study.

Methods

Measurements with the universal and parallelogram goniometers were taken in two different positions, the smaller and larger angles of active knee flexion. All measurements were taken by two trained testers. A radiograph was taken in both positions to serve as the ‘gold standard’. The sequence of the measurements and radiographs were randomly selected. The intra and intertester reliability of both goniometers were established by calculating the intraclass correlation coefficients (ICCs) using the repeated‐measures ANOVA. The criterion validity was examined by calculating Pearson product‐moment correlation coefficients (r) between each goniometric and radiologic measurements. A 0.05 level of significance was chosen for each statistical test.

Results

Intratester reliability ranged from good to excellent for the small angles (ICC=0.85 and 0.87) and the large angles (ICC=0.91 and 0.96) when using the parallelogram goniometer. Intertester reliability was fair for the small angles of flexion (ICC=0.43 to 0.52) and good to excellent for the large angles of flexion (ICC=0.82 to 0.88). The parallelogram goniometer was found to have greater validity when measuring the large angles of knee flexion (r=0.73 and 0.77) compared to the small angles of knee flexion (r=0.33 and 0.41). Similar results of reliability and validity were obtained with the universal goniometer.

Conclusion

The results of this study have clinical importance. The use of the parallelogram goniometer was found to be as reliable and valid as the universal goniometer when measuring active knee flexion. However, the parallelogram goniometer offered clinicians the advantages of obtaining precise angular measurements with fewer adjustments, and a faster application technique. Further studies on the parallelogram goniometer are necessary among individuals presenting with altered range of motion at different joints. Copyright © 1997 Whurr Publishers Ltd.

Từ khóa


Tài liệu tham khảo

BalmerS.Clinical testing of the new parallelogram goniometer. Proceedings of the 10th Canadian Medical and Biological Engineering Conference: Ottawa 1984.

Basmajian JV, 1978, Muscles Alive, 257

10.1093/ptj/58.11.1355

10.1093/ptj/68.2.214

10.1093/ptj/74.8.777

Enwemeka CS, 1986, Radiographic verification of knee goniometry, Scandinavian Journal of Rehabilitation Medicine, 18, 47, 10.2340/165019771986184749

Fleiss JL, 1986, The Design and Analysis of Clinical Experiments

10.1093/ptj/67.12.1867

10.1093/ptj/67.2.192

10.1097/00002060-199407000-00014

Lawrence MR, 1982, The Knee, Clinical Rheumatic Disorders, 8, 677, 10.1016/S0307-742X(21)00414-8

Lehmkuhl LD, 1983, Brunnstrom's Clinical Kinesiology, 303

Norkin CC, 1995, Measurement of Joint Motion: A Guide to Goniometry

O'Riain MD, 1983, A new goniometer for physiotherapy, Physiotherapy Canada, 35, 280

10.1093/ptj/68.11.1676

10.1093/ptj/63.10.1611

SPSS: Statistical Package for Social Sciences Inc., 1994, SPSS\PC+: Version 4.0.

10.1093/ptj/71.2.90