Internal porosities, retentive force, and survival of cobalt–chromium alloy clasps fabricated by selective laser-sintering

Journal of Prosthodontic Research - Tập 64 - Trang 210-216 - 2020
Josef Schweiger1, Jan-Frederik Güth1, Kurt-Jürgen Erdelt1, Daniel Edelhoff1, Oliver Schubert1
1Department of Prosthetic Dentistry, University Hospital, LMU Munich, Germany

Tài liệu tham khảo

Roach, 1930, Principles and essentials of bar clasp partial dentures, J Am Dent Assoc, 17, 124 Douglass, 2002, Future needs for fixed and removable partial dentures in the United States, J Prosthet Dent, 87, 9, 10.1067/mpr.2002.121204 Hummel, 2002, Quality of removable partial dentures worn by the adult U.S. population, J Prosthet Dent, 88, 37, 10.1067/mpr.2002.126845 Campbell, 2017, Removable partial dentures: the clinical need for innovation, J Prosthet Dent, 118, 273, 10.1016/j.prosdent.2017.01.008 Frank, 1998, Treatment outcomes with mandibular removable partial dentures: a population-based study of patient satisfaction, J Prosthet Dent, 80, 36, 10.1016/S0022-3913(98)70089-7 Maxfield, 1979, The measurement of forces transmitted to abutment teeth of removable partial dentures, J Prosthet Dent, 41, 134, 10.1016/0022-3913(79)90295-6 Mojon, 1995, Relationship between prosthodontic status, caries, and periodontal disease in a geriatric population, Int J Prosthodont, 8, 564 Hofmann, 2002, Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures, Clin Oral Investig, 6, 104, 10.1007/s00784-002-0160-9 Saito, 2002, Complications and failures in removable partial dentures: a clinical evaluation, J Oral Rehabil, 29, 627, 10.1046/j.1365-2842.2002.00898.x Rodrigues, 2002, Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures, J Prosthet Dent, 88, 290, 10.1067/mpr.2002.128128 Monroy, 2013, Study of the pore formation on CoCrMo alloys by selective laser melting manufacturing process, Procedia Eng, 63, 361, 10.1016/j.proeng.2013.08.227 Beuer, 2008, Digital dentistry: an overview of recent developments for CAD/CAM generated restorations, Br Dent J, 204, 505, 10.1038/sj.bdj.2008.350 Miyazaki, 2009, A review of dental CAD/CAM: current status and future perspectives from 20 years of experience, Dent Mater J, 28, 44, 10.4012/dmj.28.44 Beguma, 2014, Rapid prototyping—when virtual meets reality, Int J Comput Dent, 17, 297 Schubert, 2019, Digital implant planning and guided implant surgery—workflow and reliability, Br Dent J, 226, 101, 10.1038/sj.bdj.2019.44 Alharbi, 2017, Additive manufacturing techniques in prosthodontics: where do we currently stand? A critical review, Int J Prosthodont, 30, 474, 10.11607/ijp.5079 Arnold, 2018, Accuracy of CAD-CAM-fabricated removable partial dentures, J Prosthet Dent, 119, 586, 10.1016/j.prosdent.2017.04.017 Alifui-Segbaya, 2015, In vitro corrosion analyses of heat treated cobalt-chromium alloys manufactured by direct metal laser sintering, Rapid Prototyp J, 21, 111, 10.1108/RPJ-11-2012-0110 Alageel, 2018, Removable partial denture alloys processed by laser-sintering technique, J Biomed Mater Res B Appl Biomater, 106, 1174, 10.1002/jbm.b.33929 Takaichi, 2013, Microstructures and mechanical properties of Co-29Cr-6Mo alloy fabricated by selective laser melting process for dental applications, J Mech Behav Biomed Mater, 21, 67, 10.1016/j.jmbbm.2013.01.021 Kajima, 2016, Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting, J Mech Behav Biomed Mater, 59, 446, 10.1016/j.jmbbm.2016.02.032 Lapcevic, 2016, Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices, Rapid Prototyp J, 22, 144, 10.1108/RPJ-04-2014-0051 Braian, 2018, Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: a comparative in vitro study, Dent Mater, 34, 978, 10.1016/j.dental.2018.03.009 Sander, 2018, Corrosion of additively manufactured alloys: a review, Corrosion, 74, 1318, 10.5006/2926 Williams, 2006, Use of CAD/CAM technology to fabricate a removable partial denture framework, J Prosthet Dent, 96, 96, 10.1016/j.prosdent.2006.05.029 Bibb, 2006, Rapid manufacture of removable partial denture frameworks, Rapid Prototyp J, 12, 95, 10.1108/13552540610652438 Bibb, 2006, Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques, Proc Inst Mech Eng H, 220, 793, 10.1243/09544119JEIM62 Han, 2010, A preliminary report of designing removable partial denture frameworks using a specifically developed software package, Int J Prosthodont, 23, 370 Wu, 2012, A study on the fabrication method of removable partial denture framework by computer-aided design and rapid prototyping, Rapid Prototyp J, 18, 318, 10.1108/13552541211231743 Yager, 2015, Mechanical properties and microstructure of removable partial denture clasps manufactured using selective laser melting, Addit Manuf, 8, 117, 10.1016/j.addma.2015.09.005 Hu, 2017, Using intraoral scanning technology for three-dimensional printing of Kennedy Class I removable partial denture metal framework: a clinical report, J Prosthodont, 28, e473, 10.1111/jopr.12712 Nakata, 2017, Clasp fabrication using one-process molding by repeated laser sintering and high-speed milling, J Prosthodont Res, 61, 276, 10.1016/j.jpor.2016.10.002 Alsheghri, 2018, An analytical model to design circumferential clasps for laser-sintered removable partial dentures, Dent Mater, 34, 1474, 10.1016/j.dental.2018.06.011 Kim, 2018, Effect of cyclic bend loading on a cobalt-chromium clasp fabricated by direct metal laser sintering, J Prosthet Dent, 119, 1027.e1, 10.1016/j.prosdent.2018.03.016 Torii, 2018, Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling, J Prosthodont Res, 62, 342, 10.1016/j.jpor.2018.01.001 Yan, 2018, Effect of two heat treatments on mechanical properties of selective-laser-melted Co-Cr metal-ceramic alloys for application in thin removable partial dentures, J Prosthet Dent, 119, 1028.e1, 10.1016/j.prosdent.2018.04.002 Soltanzadeh, 2019, An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks, J Prosthodont, 28, 547, 10.1111/jopr.12997 JM Ney Company, 1963 Meier, 1958, Nonparametric estimation from incomplete observations AU—Kaplan, E. L, J Am Dent Assoc, 53, 457 Tokue, 2013, Fatigue resistance and retentive force of cast clasps treated by shot peening, J Prosthodont Res, 57, 186, 10.1016/j.jpor.2013.01.006 Merk, 2016, Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper, Materials (Basel), 9, 908, 10.3390/ma9110908 Joguet, 2016, Porosity content control of CoCrMo and titanium parts by Taguchi method applied to selective laser melting process parameter, Rapid Prototyp J, 22, 20, 10.1108/RPJ-09-2013-0092 Gupta, 1992, Pore formation in cast metals and alloys, J Mater Sci, 27, 853, 10.1007/BF01197634 Arda, 2005, An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps, J Prosthet Dent, 94, 267, 10.1016/j.prosdent.2005.06.009 Cheng, 2010, Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses, J Prosthet Dent, 104, 389, 10.1016/S0022-3913(10)60173-4 Ohkawa, 1990, Changes in retention of various telescope crown assemblies over long-term use, J Prosthet Dent, 64, 153, 10.1016/0022-3913(90)90170-H Vallittu, 1995, Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp, J Prosthet Dent, 74, 412, 10.1016/S0022-3913(05)80384-1 Ahmad, 1992, The effect of reducing the number of clasps on removable partial denture retention, J Prosthet Dent, 68, 928, 10.1016/0022-3913(92)90553-M Sato, 2001, Finite element analysis on preferable I-bar clasp shape, J Oral Rehabil, 28, 413, 10.1046/j.1365-2842.2001.00673.x Schubert, 2019, Retentive force of PEEK secondary crowns on zirconia primary crowns over time, Clin Oral Investig, 23, 2331, 10.1007/s00784-018-2657-x Tan, 2019, Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study, J Prosthodont Res, 63, 58, 10.1016/j.jpor.2018.08.002