Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests
Tóm tắt
Từ khóa
Tài liệu tham khảo
Aagaard, 2010, The use of eccentric strength training to enhance maximal muscle strength, explosive force (RDF) and muscular power – consequences for athletic performance, The Open Sports Sciences Journal, 3, 52, 10.2174/1875399X01003010052
Aagaard, 1998, A new concept for isokinetic hamstring: quadriceps muscle strength ratio, American Journal of Sports Medicine, 26, 231, 10.1177/03635465980260021201
Almosnino, 2012, Reproducibility of isokinetic knee eccentric and concentric strength indices in asymptomatic young adults, Physical Therapy in Sport, 13, 156, 10.1016/j.ptsp.2011.09.002
Anderson, 2007, Maximum voluntary joint torque as a function of joint angle and angular velocity: model development and application to the lower limb, Journal of Biomechanics, 40, 3105, 10.1016/j.jbiomech.2007.03.022
Atkinson, 1998, Statistical methods for assessing measurement error (reliability) in variables relevant to sport medicine, Sports Medicine, 26, 217, 10.2165/00007256-199826040-00002
Ayala, 2012, Absolute reliability of hamstring to quadriceps strength imbalance ratios calculated using peak torque, joint angle-specific torque and joint ROM-specific torque values, International Journal of Sports Medicine, 33, 909, 10.1055/s-0032-1311586
Bandy, 1993, Intramachine and intermachine reliability for selected dynamic muscle performance test, The Journal of Orthopaedic and Sports Physical Therapy, 18, 609, 10.2519/jospt.1993.18.5.609
Baroni, 2013, Functional and morphological adaptations to aging in knee extensor muscles of physically active men, Journal of Applied Biomechanics, 29, 535, 10.1123/jab.29.5.535
Baroni, 2010, Effect of Light-Emitting Diodes Therapy (LEDT) on knee extensor muscle fatigue, Photomedicine and Laser Surgery, 28, 653, 10.1089/pho.2009.2688
Baroni, 2013, Time course of neuromuscular adaptations to knee extensor eccentric training, International Journal of Sports Medicine, 34, 904, 10.1055/s-0032-1333263
Borges, 2003, The torque-velocity relations of elite soccer players, Journal of Sports Medicine and Physical Fitness, 43, 261
Brown, 2000
Correa, 2013, Effects of strength training and detraining on knee extensor strength, muscle volume and muscle quality in elderly women, Age, 35, 1899, 10.1007/s11357-012-9478-7
Cotte, 2003, Comparative study of two isokinetics dynamometers: CYBEX-NORM vs COM-TREX MJ, Isokinetics and Exercise Science, 11, 37, 10.3233/IES-2003-0111
Dirnberger, 2012, Concentric and eccentric knee extension: a reproducibility study using the IsoMed 2000-dynamometer, Isokinetics and Exercise Science, 20, 31, 10.3233/IES-2012-0437
Drouin, 2004, Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurement, European Journal of Applied Physiology, 91, 22, 10.1007/s00421-003-0933-0
Dvir, 2003, How much is necessary to indicate a real improvement unmuscle function? A review of modern methods of reproducibility analysis, Isokinetic and Exercise Science, 11, 49, 10.3233/IES-2003-0109
Dvir, 1989, Thigh muscles activity and anterior cruciate ligament insufficiency, Clinical Biomechanics (Bristol, Avon), 4, 87, 10.1016/0268-0033(89)90044-2
2008
Emery, 1999, Test-retest reliability of isokinetic hip adductor and flexor muscle strength, Clinical Journal of Sport Medicine, 9, 79, 10.1097/00042752-199904000-00007
Francis, 1987, Comparison of peak torque values of the knee flexor and extensor muscle groups using the cybex II and lido 2.0 isokinetic dynamometers, The Journal of Orthopaedic and Sports Physical Therapy, 8, 480, 10.2519/jospt.1987.8.10.480
Gross, 1991, Intramachine and intermachine reliability of the biodex and cybex II for knee flexion and extension peak torque and angular work, The Journal of Orthopaedic and Sports Physical Therapy, 13, 329, 10.2519/jospt.1991.13.6.329
Hamill, 2009
Hopkins, 2000, Measures of reliability in sports medicine and science, Sports Medicine, 30, 1, 10.2165/00007256-200030010-00001
Impellizzeri, 2008, Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer, Clinical Physiology and Functional Imaging, 28, 113, 10.1111/j.1475-097X.2007.00786.x
Kannus, 1994, Isokinetic evaluation of muscular Performance: Implications for muscle testing and rehabilitation. Review, International Journal of Sports Medicine, 15, S11, 10.1055/s-2007-1021104
Keilani, 2007, Comparison of values generated during isokinetic-testing of the knee extensor and flexor muscles using the cybex 6000 and biodex 3 isokinetic dynamometer. ABSTRACT, Physikalische Medizin, Rehabilitationsmedizin, Kurortmedizin, 17, 327, 10.1055/s-2007-973833
Li, 1996, Eccentric and concentric isokinetic knee flexion and extension: a reliability study using the Cybex 6000 dynamometer, British Journal of Sports Medicine, 30, 156, 10.1136/bjsm.30.2.156
Lorenz, 2011, The role and implementation of eccentric training in athletic rehabilitation: tendinopathy, hamstring strains, and ACL reconstruction, International Journal of Sports and Physical Therapy, 6, 27
Lund, 2005, Learning effect of isokinetic measurements in healthy subjects, and reliability and comparability of Biodex and Lido dynamometers, Clinical Physiology and Functional Imaging, 25, 75, 10.1111/j.1475-097X.2004.00593.x
Murphy, 1997, The ability of tests of muscular function to reflect training-induced changes in performance, Journal of Sports Sciences, 15, 191, 10.1080/026404197367461
Petersen, 2011, Preventive effect of eccentric training on acute hamstrings injuries in men’s soccer: a cluster randomized controlled trial, American Journal of Sports Medicine, 39, 2296, 10.1177/0363546511419277
Pierce, 2008, Roles of reflex activity and co-contraction during assessments of spasticity of the knee flexor and extensor muscles in children with cerebral palsy and different functional levels, Physical Therapy, 88, 1124, 10.2522/ptj.20070331
Pinto, 2014, Effects of intra-session exercise sequence during water-based concurrent training, International Journal of Sports Medicine, 35, 41
Pinto, 2010, Electromyographic signal and force comparisons during maximal voluntary isometric contraction in water and on dry land, European Journal of Applied Physiology, 110, 1075, 10.1007/s00421-010-1598-0
Quittan, 2001, Isokinetic strength testing in patients with chronic heart failure – a reliability study, International Journal of Sports Medicine, 22, 40, 10.1055/s-2001-11360
Sole, 2007, Test-retest reliability of isokinetic knee extension and flexion, Archives of Physical Medicine and Rehabilitation, 88, 626, 10.1016/j.apmr.2007.02.006
Thompson, 1989, Comparison of values generated during testing of the knee using the cybex II plus and the biodex model B-2000 isokinetic dynamometers, The Journal of Orthopaedic and Sports Physical Therapy, 11, 108, 10.2519/jospt.1989.11.3.108
Tsiros, 2012, Knee extensor strength differences in obese and healthy-weight 10 to 13-years-old, European Journal of Applied Physiology