Acquart S, Gain P, Zhao M, Gavet Y, Defreyn A, Piselli S, Garraud O, Thuret G (2010) Endothelial morphometry by image analysis of corneas organ cultured at 31 °C. Invest Ophthalmol Vis Sci 51(3):1356–1364. doi:10.1167/iovs.08-3103
Amann J, Holley GP, Lee SB, Edelhauser HF (2003) Increased endothelial cell density in the paracentral and peripheral regions of the human cornea. Am J Ophthalmol 135(5):584–590
Benetz BA, Lass JH, Gal RL, Sugar A, Menegay H, Dontchev M, Kollman C, Beck RW, Mannis MJ, Holland EJ, Gorovoy M, Hannush SB, Bokosky JE, Caudill JW (2013) Endothelial morphometric measures to predict endothelial graft failure after penetrating keratoplasty. JAMA Ophthalmol 131(5):601–608. doi:10.1001/jamaophthalmol.2013.1693
Binder PS, Akers P, Zavala EY (1979) Endothelial cell density determined by specular microscopy and scanning electron microscopy. Ophthalmology 86(10):1831–1847
De Boroviczeny CG (1966) On the standardization of the blood cell counts. Bibl Haematol 24:2–31
Deb-Joardar N, Thuret G, Gavet Y, Acquart S, Garraud O, Egelhoffer H, Gain P (2007) Reproducibility of endothelial assessment during corneal organ culture: comparison of a computer-assisted analyzer with manual methods. Invest Ophthalmol Vis Sci 48(5):2062–2067. doi:10.1167/iovs.06-1043
EEBA (2012) European Eye Bank Association Directory. Twentieth edition. Amsterdam
Flury M, He Z, Campolmi N, Gain P, Kress B, Thuret G (2012) Fabrication of optical mosaics mimicking human corneal endothelium for the training and assessment of eye bank technicians. Opt Lett 37(1):22–24. doi:10.1364/OL.37.000022
Gundersen HG (1977) Notes on estimation of the numerical density of arbitrary profiles: the edge effect. J Microsc 111(2):219–223
Gundersen HJ (1978) Estimators of the number of objects per area unbiased by edge effects. Microsc Acta 81(2):107–117
Jonuscheit S, Doughty MJ, Ramaesh K (2012) Assessment of a variable frame (polygonal) method to estimate corneal endothelial cell counts after corneal transplantation. Eye (Lond) 26(6):803–809. doi:10.1038/eye.2012.42
Pels L (1997) Organ culture: the method of choice for preservation of human donor corneas. Br J Ophthalmol 81(7):523–525
Rao GN, Aquavella JV, Goldberg SH, Berk SL (1984) Pseudophakic bullous keratopathy. Relationship to preoperative corneal endothelial status. Ophthalmology 91(10):1135–1140
Shaw EL, Rao GN, Arthur EJ, Aquavella JV (1978) The functional reserve of corneal endothelium. Ophthalmology 85(6):640–649
Tan DT, Dart JK, Holland EJ, Kinoshita S (2012) Corneal transplantation. Lancet 379(9827):1749–1761. doi:10.1016/S0140-6736(12)60437-1
Thuret G, Manissolle C, Acquart S, Le Petit JC, Maugery J, Campos-Guyotat L, Doughty MJ, Gain P (2003) Is manual counting of corneal endothelial cell density in eye banks still acceptable?The French experience. Br J Ophthalmol 87(12):1481–1486
Thuret G, Manissolle C, Acquart S, Garraud O, Campos-Guyotat L, Maugery J, Gain P (2004) Urgent need for normalization of corneal graft quality controls in French eye banks. Transplantation 78(9):1299–1302.